Analysis of Results of Digital Electroencephalography and Digital Vectors of Coronavirus Images upon Applying the Theory of Covariance Functions

被引:0
|
作者
Skeivalas, Jonas [1 ]
Parseliunas, Eimuntas [1 ]
Parseliunas, Audrius [2 ]
Slikas, Dominykas [1 ]
机构
[1] Vilnius Gediminas Tech Univ, Dept Geodesy & Cadastre, Sauletekis Av 11, LT-10223 Vilnius, Lithuania
[2] Lithuanian Univ Hlth Sci, Dept Gen Surg, A Mickevicius St 9, LT-44307 Kaunas, Lithuania
来源
SYMMETRY-BASEL | 2023年 / 15卷 / 07期
关键词
electroencephalography; SARS-CoV-2; covariance function; quantised interval; TRANSMISSION DYNAMICS; COVID-19;
D O I
10.3390/sym15071330
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper analyses the structures of covariance functions of digital electroencephalography measurement vectors and digital vectors of two coronavirus images. For this research, we used the measurement results of 30-channel electroencephalography (E1-E30) and digital vectors of images of two SARS-CoV-2 variants (cor2 and cor4), where the magnitudes of intensity of the electroencephalography parameters and the parameters of the digital images of coronaviruses were encoded. The estimators of cross-covariance functions of the digital electroencephalography measurements' vectors and the digital vectors of the coronavirus images and the estimators of auto-covariance functions of separate vectors were derived by applying random functions constructed according to the vectors' parameter measurement data files. The estimators of covariance functions were derived by changing the values of the quantised interval k on the time and image pixel scales. The symmetric matrices of correlation coefficients were calculated to estimate the level of dependencies between the electroencephalography measurement results' vectors and the digital vectors of the coronavirus images. The graphical images of the normalised cross-covariance functions for the electroencephalography measurement results' vectors and the digital vectors of the coronavirus images within the period of all measurements are asymmetric. For all calculations, a computer program was developed by applying a package of Matlab procedures. A probabilistic interdependence between the results of the electroencephalography measurements and the parameters of the coronavirus vectors, as well as their variation on the time and image pixel scales, was established.
引用
收藏
页数:12
相关论文
共 16 条
  • [1] AN ANALYSIS OF VARIATION OF GEOMAGNETIC FIELD PARAMETERS UPON APPLYING THE THEORY OF COVARIANCE FUNCTIONS
    Skeivalas, Jonas
    Obuchovski, Romuald
    METROLOGY AND MEASUREMENT SYSTEMS, 2019, 26 (02) : 363 - 376
  • [2] The analysis of gravimeter performance by applying the theory of covariance functions
    J. Skeivalas
    R. Obuchovski
    A. Kilikevičius
    Indian Journal of Physics, 2019, 93 : 1377 - 1384
  • [3] The analysis of gravimeter performance by applying the theory of covariance functions
    Skeivalas, J.
    Obuchovski, R.
    Kilikevicius, A.
    INDIAN JOURNAL OF PHYSICS, 2019, 93 (11) : 1377 - 1384
  • [4] On identification of human eye retinas by the covariance analysis of their digital images
    Skeivalas, Jonas
    Parseliunas, Eimuntas
    OPTICAL ENGINEERING, 2013, 52 (07)
  • [5] Contrast enhancement in grayscale digital images applying atomic functions in fuzzy logic
    Kravchenko, V.F. (kvf-ok@mail.ru), 1787, Begell House Inc. (72):
  • [6] Applying Rough Set Theory for Digital Forensics Evidence Analysis
    Gupta, Khushi
    Jinad, Razaq
    Bing, Zhou
    ROUGH SETS, IJCRS 2022, 2022, 13633 : 71 - 84
  • [7] Differentiating three Indian shads by applying shape analysis from digital images
    Dwivedi, Arvind K.
    JOURNAL OF FISH BIOLOGY, 2020, 96 (06) : 1298 - 1308
  • [8] EXPERIMENTAL RESULTS OF THE DIGITAL INVERSE FILTERING OF RADIOGRAPHIC IMAGES FOR TOMOGRAPHIC ANALYSIS
    WAINSCHENKER, R
    CASELLI, E
    RODRIGUEZ, ME
    OPTIK, 1994, 98 (02): : 71 - 73
  • [9] Experimental results of the digital inverse filtering of radiographic images for tomographic analysis
    Wainschenker, R.
    Caselli, E.
    Rodriguez, M.E.
    Optik (Stuttgart), 1994, 98 (02):
  • [10] Quality analysis of real-time digital broadcasting images applying the Qoe measurement technology
    Hong, Bong-Hwa
    Joo, Hae-Jong
    Lee, Eu-Soo
    JOURNAL OF REAL-TIME IMAGE PROCESSING, 2014, 9 (03) : 579 - 585