Thermo-fluid dynamic analysis of HLM pool. Circe experiments

被引:0
|
作者
Martelli, D. [1 ]
Marinari, R. [1 ]
Di Piazza, I. [1 ]
Lorusso, P. [1 ]
Tarantino, M. [1 ]
机构
[1] ENEA, Dept Fus & Nucl Safety Technol, I-40032 Camugnano, BO, Italy
关键词
Compilation and indexing terms; Copyright 2025 Elsevier Inc;
D O I
10.1016/j.nucengdes.2023.112347
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This work reports a summary of the experimental and numerical activities performed to investigate thermal hydraulic phenomena occurring in response to hypo-thetical accidental scenarios of Protected Loss of Heat Sink (PLOHS), and Protected Loss of Flow (PLOFA) and the heat transfer in the lead-bismuth (LBE) cooled fuel pin bundle simulator (FPS) of the CIRCE facility.A series of four experiments (PLOHS-PLOFA) were carried out simulating the total loss of the secondary circuit and the coolant pump trip with the subsequent simulation of the reactor scram (reduction of the electric power supplied to the fuel pin simulator) and activation of DHR system to remove the decay heat power (-5% of the nominal value).Tests differ from each other by the applied boundary conditions such as the electrical power supplied to the Fuel Pin Simulator, the duration of the test, the power removed by the HX etc., while test #4 also differs for the forced circulation maintained after the simulation of the accidental transient.In parallel experimental test were carried out to investigate the heat transfer in a wrapped, grid spaced FPS. The FPS is composed of 37 electrical pins placed on a hexagonal lattice with a pitch to diameter ratio of 1.8. The bundle is hosted in the CIRCE large pool facility and represents the hot source of the Integral Circulation Experiment (ICE) test section.Several thermocouples (0.5 mm O.D.) are installed in the FPS to measure both clad and subchannel LBE temperatures at different ranks and two different sections. Experimental data are used to evaluate the Nu number in the Pe range 500-3000 and obtained data are compared with Ushakov and Mikityuk correlations having a validity range containing the experimental p/d ratio and for the selected Pe range.Experimental data relating to the obtained Nu number and the thermal hydraulic phenomena such as the modification of the thermal stratification in "pool type" configuration, coolant mass flow rate adaptation in the test section occurring during the simulation of the designed accidental conditions and the capability to cool the FPS under natural circulation conditions are described in this paper. Finally, the experimental database was used for validation of the geometrical and numerical model of the FPS adopted for 3D CFD calculations. In the performed simulations a sensitivity analysis was carried out for the turbulent Prandtl number in the range between 1 and 3 and a comparison between the first order turbulence model k-omega SST and the higher order Reynolds Stress Model was accomplished.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] HLM fuel pin bundle experiments in the CIRCE pool facility
    Martelli, Daniele
    Forgione, Nicola
    Di Piazza, Ivan
    Tarantino, Mariano
    NUCLEAR ENGINEERING AND DESIGN, 2015, 292 : 76 - 86
  • [2] Thermo-fluid dynamic analysis of wet compression process
    Abhay Mohan
    Palani Kumar Chidambaram
    Abhilash Suryan
    Heuy Dong Kim
    Journal of Mechanical Science and Technology, 2016, 30 : 5473 - 5483
  • [3] Thermo-fluid dynamic analysis of wet compression process
    Mohan, Abhay
    Chidambaram, Palani Kumar
    Suryan, Abhilash
    Kim, Heuy Dong
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2016, 30 (12) : 5473 - 5483
  • [4] FEM FOR THERMO-FLUID BEARING DYNAMIC CHARACTERISTICS
    PARSZEWSKI, ZA
    NAN, X
    LI, DX
    COMPUTERS & STRUCTURES, 1989, 31 (01) : 93 - 102
  • [5] A thermo-fluid analysis in magnetic hyperthermia
    Astefanoaei, Iordana
    Dumitru, Ioan
    Stancu, Alexandru
    Chiriac, Horia
    CHINESE PHYSICS B, 2014, 23 (04)
  • [6] Thermo-fluid analysis in automotive engines
    Mahmoud, KG
    Ennemoser, A
    Baier, W
    VTMS 4: VEHICLE THERMAL MANAGEMENT SYSTEMS, 1999, : 695 - 705
  • [7] A thermo-fluid analysis in magnetic hyperthermia
    Iordana Astefanoae
    Ioan Dumitru
    Alexandru Stancu
    Horia Chiriac
    Chinese Physics B, 2014, (04) : 362 - 368
  • [8] THERMO-FLUID DYNAMIC ANALYSIS OF A GAS TURBINE TRANSITION-PIECE
    Da Soghe, Riccardo
    Bianchini, Cosimo
    Andreini, Antonio
    Mazzei, Lorenzo
    Riccio, Giovanni
    Marini, Alessandro
    Ciani, Alessandro
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2014, VOL 5C, 2014,
  • [9] The use of a thermo-fluid dynamic efficiency in cooling towers
    Sirena, JA
    HEAT TRANSFER ENGINEERING, 2002, 23 (02) : 22 - 30
  • [10] Computational thermo-fluid analysis of a disk brake
    Kenji Takizawa
    Tayfun E. Tezduyar
    Takashi Kuraishi
    Shinichiro Tabata
    Hirokazu Takagi
    Computational Mechanics, 2016, 57 : 965 - 977