Multi-electrode scale-up strategy and parametric investigation of redox-flow desalination systems

被引:18
|
作者
Kim, Hyunjin [1 ,2 ]
Kim, Seonghwan [1 ,2 ,3 ]
Kim, Nayeong [4 ]
Su, Xiao [4 ]
Kim, Choonsoo [1 ,2 ]
机构
[1] Kongju Natl Univ, Inst Energy Environm Convergence Technol, Dept Environm Engn, 1223-24 Cheonan Daero, Cheonan Si 31080, South Korea
[2] Kongju Natl Univ, Dept Future Convergence Engn, 1223-24 Cheonan Daero, Cheonan Si 31080, South Korea
[3] Samsung Elect Co Ltd, Samsung Res, Suwon, South Korea
[4] Univ Illinois, Dept Chem & Biomol Engn, Champaign, IL 61801 USA
基金
新加坡国家研究基金会;
关键词
Desalination; Redox flow desalination; Scale-up; Multi-electrode stacking; Techno-economic analysis; MEMBRANE CAPACITIVE DEIONIZATION; SEAWATER DESALINATION; WATER DESALINATION; ENERGY-CONSUMPTION; ELECTROCHEMICAL DESALINATION; CELL VOLTAGE; TECHNOLOGIES; STREAM;
D O I
10.1016/j.desal.2022.116350
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Redox flow desalination (RFD) has emerged as a promising energy-efficient and sustainable electrochemical ion separation process for water desalination. Despite the effectiveness of RFD systems for desalination, prior studies have generally focused on fundamental aspects and lab-scale studies; therefore, the practical feasibility and potential for deployment in industry remain unclear. Here, a strategy for scaling-up RFD systems was developed, and the efficacy of RFD for desalination on a larger scale and its practical feasibility for industrial applications were assessed. A new multielectrode stacking strategy employing a carbon electrode and titanium current col -lector enabled enhanced charge transfer and improved desalination performance without the need for additional channels. This facile strategy of scaling up the RFD remarkably reduces the size of the system compared with unit cell stacking in the conventional electrochemical system. The larger scale RFD system exhibited a salt removal rate of 852 mmol/m2/h and specific energy consumption of 120 kJ/mol ( approximately equal to 0.1 kWh/m3). Multi-parametric optimization was carried out via interactive data visualization by varying the cell voltage, flow rate, number of carbon electrode stacks, and membrane arrangement. The RFD system achieved an energy consumption of 60-80 kJ/mol and removal rate of 200-300 mmol/m2/h. Overall, the feasibility of RFD for water desalination was confirmed through a rational scale-up strategy, comprehensive understanding of the desalination parameters, and techno-economic analysis. Through continued development and further scale-up investigations, we envision the deployment of RFD systems for energy-efficient desalination on the industrial scale as an alternative to conventional electrochemical desalination processes (i.e., electrodialysis and capacitive deionization).
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Efficient PEDOT Electrode Architecture for Continuous Redox-Flow Desalination
    Ramalingam, Karthick
    Zhu, Yuchao
    Wang, Jian
    Liang, Mengjun
    Wei, Qiang
    Chen, Xuncai
    Sun, Fei
    Chen, Deyang
    Zhang, Zhang
    Aung, Su Htike
    Oo, Than Zaw
    Chen, Fuming
    ACS SUSTAINABLE CHEMISTRY & ENGINEERING, 2021, 9 (38) : 12779 - 12787
  • [2] Scale-Up Strategies for Redox-Mediated Electrodialysis for Desalination: The Role of Electrode and Channel Stacks
    Kim, Gamin
    Kim, Hyunjin
    Kim, Minhui
    Kim, Nayeong
    Lee, Byeongho
    Kim, Seonghwan
    Su, Xiao
    Kim, Choonsoo
    CHEMSUSCHEM, 2025,
  • [3] Parametric investigation of ferri/ferrocyanide redox flow for performance optimization of redox flow desalination
    Kim, Youchang
    Jeon, Seongbeom
    Ahn, Dayoung
    Kim, Hyunjin
    Kim, Choonsoo
    Lee, Yunho
    DESALINATION, 2023, 550
  • [4] Scale-up desalination: Membrane-current collector assembly in flow-electrode capacitive deionization system
    Xu, Longqian
    Mao, Yunfeng
    Zong, Yang
    Wu, Deli
    WATER RESEARCH, 2021, 190
  • [5] A Scale-up Strategy for the Fluid Flow inBiogas Plants
    Annas, Sven
    Jantzen, Hans-Arno
    Scholz, Juergen
    Janoske, Uwe
    CHEMICAL ENGINEERING & TECHNOLOGY, 2018, 41 (04) : 739 - 746
  • [6] Redox-Flow Desalination with a Voltage Range Extending up to 2 V Under Dual-pH Conditions
    Kim, Byeongkyu
    Mule, Anki Reddy
    Kim, Yong Seok
    Gudal, Chandan Chandru
    Kim, Na Hyeon
    Ko, Eunchae
    Kim, Seong Soo
    Chung, Chan-Hwa
    CHEMELECTROCHEM, 2024, 11 (08)
  • [7] Scale-up of high power density redox flow batteries by introducing interdigitated flow fields
    You, Xin
    Ye, Qiang
    Cheng, Ping
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2016, 75 : 7 - 12
  • [8] Scale-up and Modelling of Flow-electrode CDI Using Tubular Electrodes
    He, Calvin
    Lian, Boyue
    Ma, Jinxing
    Zhang, Changyong
    Wang, Yuan
    Mo, Hengliang
    Waite, T. David
    WATER RESEARCH, 2021, 203
  • [9] An experimental investigation into the scale-up of oscillatory flow mixing in baffled tubes
    Smith, K. B.
    Mackley, M. R.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2006, 84 (A11): : 1001 - 1011
  • [10] Status Update on Bioelectrochemical Systems: Prospects for Carbon Electrode Design and Scale-Up
    Herkendell, Katharina
    CATALYSTS, 2021, 11 (02) : 1 - 18