Reproducibility and determinants of the metabolic responses during a mixed-meal tolerance test

被引:4
|
作者
Stinson, Emma J. [1 ]
Piaggi, Paolo [1 ,2 ]
Mitchell, Cassie M. [1 ]
Redman, Leanne M. [3 ]
Krakoff, Jonathan [1 ,4 ]
机构
[1] NIDDKD, Obes & Diabet Clin Res Sect, Phoenix Epidemiol & Clin Res Branch, NIH, Phoenix, AZ USA
[2] Univ Pisa, Dept Informat Engn, Pisa, Italy
[3] Pennington Biomed Res Ctr, Baton Rouge, LA USA
[4] NIDDKD, Obes & Diabet Clin Res Sect, Phoenix Epidemiol & Clin Res Branch, 4212 N 16th St, Phoenix, AZ 85016 USA
关键词
IMPAIRED GLUCOSE-TOLERANCE; BETA-CELL FUNCTION; INSULIN-SECRETION; PREDICTOR; HEALTH; IMPACT;
D O I
10.1002/oby.23678
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The aim of this study was to assess the reproducibility and physiological determinants of mixed-meal tolerance tests (MMTTs) on glucose and insulin responses. Methods: While inpatients on a weight-maintaining diet, 894 individuals (574 with normal and 267 with impaired glucose regulation and 53 with type 2 diabetes [T2D]) underwent 9-hour MMTTs (breakfast and lunch; 30% weight-maintaining diet each; 40% carbohydrate, 40% fat, and 20% protein). Total/incremental areas under the curve (AUC/iAUC) were calculated from MMTT plasma glucose/insulin concentrations. Acute insulin response (AIR) was quantified by intravenous glucose tolerance test and insulin action (M) via hyperinsulinemic-euglycemic clamp. A subset had repeat MMTTs (median follow-up = 1.4 years). Results: In individuals without T2D, for breakfast-versus-lunch reproducibility of glucose, AUCs were moderate (intraclass correlation coefficients [ICCs]: 0.44-0.61), and iAUCs were poor (ICCs < 0.15). For repeated MMTTs, reproducibility of AUC/iAUCs was low (ICCs: 0.11-0.36). For insulin, AUC reproducibility was high (ICCs > 0.70), and iAUCs were moderate (ICCs: 0.64-0.71). For repeated MMTTs, ICC AUC/iAUCs were 0.34 to 0.54. In those with T2D, ICC glucose AUC/iAUCs were >0.80 and >0.50, respectively, and for insulin were <0.40. For repeated MMTTs, ICC glucose/insulin AUC/iAUCs were moderate. Glucose AUCs associated with M/AIR (partial Rs < -0.25), and insulin AUCs negatively/positively associated with M/AIR (partial Rs = -0.51/0.24). Conclusions: Reproducibility of glucose/insulin responses to MMTTs varied by subtraction of fasting values, glucose status, and time. Insulin secretion and action explained similar to 20% of MMTT responses. The substantial variability in MMTT response requires consideration in studies using MMTT outcomes.
引用
收藏
页码:768 / 779
页数:12
相关论文
共 50 条
  • [1] Measures of β-cell function during the oral glucose tolerance test, liquid mixed-meal test, and hyperglycemic clamp test
    Bacha, Fida
    Gungor, Neslihan
    Arslanian, Silva A.
    JOURNAL OF PEDIATRICS, 2008, 152 (05): : 618 - 621
  • [2] GLYCEMIC RESPONSES FOLLOWING A MIXED-MEAL TOLERANCE TEST AMONG CHINESE, MALAY AND ASIAN-INDIANS IN SINGAPORE
    Tan, V.
    Venkataraman, K.
    Tai, E. S.
    Lee, Y. S.
    Leow, M. K. S.
    Khoo, C. M.
    ANNALS OF NUTRITION AND METABOLISM, 2013, 63 : 1214 - 1214
  • [3] Mycoprotein reduces endogenous glucose production when consumed with a mixed-meal tolerance test
    Whelehan, G.
    West, S.
    Finnigan, T. J. A.
    Wall, B. T.
    Stephens, F. B.
    PROCEEDINGS OF THE NUTRITION SOCIETY, 2021, 80 (OCE3)
  • [4] Indices of Insulin Secretion during a Liquid Mixed-Meal Test in Obese Youth with Diabetes
    Bacha, Fida
    Gungor, Neslihan
    Lee, Sojung
    de las Heras, Javier
    Arslanian, Silva
    JOURNAL OF PEDIATRICS, 2013, 162 (05): : 924 - 929
  • [5] Effect of Pramlintide and Liraglutide on Glucagon and Glucose after a Mixed-Meal Tolerance Test in Type 1 Diabetes
    Galderisi, Alfonso
    Patel, Neha S.
    Van Name, Michelle A.
    Cengiz, Eda
    Weinzimer, Stuart A.
    Tamborlane, William V.
    Sherr, Jennifer L.
    DIABETES, 2017, 66 : A302 - A302
  • [6] Comparison of metabolic responses to the mixed meal tolerance test vs the oral glucose tolerance test after successful clinical islet transplantation
    Forbes, Shareen
    Lam, Anna
    Koh, Angela
    Imes, Sharleen
    Dinyari, Parastoo
    Malcolm, Andrew J.
    Shapiro, A. M. James
    Senior, Peter A.
    CLINICAL TRANSPLANTATION, 2018, 32 (08)
  • [7] Effects of Anesthesia on Metabolic Responses to Mixed Meal Tolerance Test in Cynomolgus Monkeys with Naturally Occurring Diabetes
    Wang, Xiaoli
    Liu, Yongqiang
    Wang, Bingdi
    Sun, Guofeng
    Chng, Keefe
    Xiao, Yong-Fu
    Wang, Yi-Xin
    DIABETES, 2015, 64 : A497 - A497
  • [8] Mixed-Meal Tolerance Test Versus Glucagon Stimulation Test for the Assessment of β-Cell Function in Therapeutic Trials in Type 1 Diabetes
    Greenbaum, Carla J.
    Mandrup-Poulsen, Thomas
    Friedenberg, Paula
    Battelino, Tadej
    Haastert, Burkhard
    Ludvigsson, Johnny
    Pozzilli, Paolo
    Lachin, John M.
    Kolb, Hubert
    DIABETES CARE, 2008, 31 (10) : 1966 - 1971
  • [9] The impact of insulin administration during the mixed meal tolerance test
    Besser, R. E. J.
    Jones, A. G.
    McDonald, T. J.
    Shields, B. M.
    Knight, B. A.
    Hattersley, A. T.
    DIABETIC MEDICINE, 2012, 29 (10) : 1279 - 1284
  • [10] Prevalence and pathophysiology of early dumping in patients after primary Roux-en-Y gastric bypass during a mixed-meal tolerance test
    Rogers, Ann M.
    SURGERY FOR OBESITY AND RELATED DISEASES, 2019, 15 (01) : 82 - 82