How to Avoid Errors When Using Navigation to Place Implants-A Narrative Review

被引:4
|
作者
Block, Michael S. [1 ,2 ]
机构
[1] LSU Sch Dent, Dept Oral & Maxillofacial Surg, Metairie, LA USA
[2] Ctr Dent Reconstruct, OMS 110,Vet Mem Blvd Metairie, Metairie, LA 70005 USA
关键词
BEAM COMPUTED-TOMOGRAPHY; GUIDED SURGERY; DYNAMIC NAVIGATION; ACCURACY; BONE; COMPLICATIONS; MULTISLICE; TEMPLATES; SYSTEM; TEETH;
D O I
10.1016/j.joms.2022.11.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: Surgeons placing implants use navigation for implant placement accuracy. The importance of this review is to document the sources of error that are involved with navigation so surgeons can recognize factors to decrease error. The objective is to provide surgeons with a reference to optimize navigation.Methods: Pubmed.gov was the information source. Years reviewed included 2010 to 2022. The inclu-sion criteria included only articles in peer-reviewed journals. In vitro results were included only if they involved testing of variables microgap, cone beam computerized tomography (CBCT) accuracy evaluation, or accuracy of printed models. Variables were searched and evaluated. Data collected included the objec-tives and outcomes of the study including statistical significance. The conclusions made by the authors were confirmed by evaluating the data analysis, and then these conclusions were listed in each error -related topic.Results: The search used terms which included guided implant surgery complications (n = 4,029), accuracy of CBCT scanners (n = 319), accuracy of implant navigation (n = 983), and the error between drills and static guides (n = 3). From this search, 70 articles were collated that satisfied the inclusion criteria. There are multiple sources of error that are less than 1 mm, including but not limited to errors associated with the scanner and method for scanning, errors associated with merging scanned files with the CBCT scan, errors using different guide stent fabrication methods, errors associated with intra-operative techniques, the learning curve, and planning error. If small errors are not taken into consider-ation, implant placement errors can exceed 1-2 mm of platform location and angulation errors in excess of 8 degrees.Conclusion: The surgeon needs to take into consideration controllable factors that will result in the avoidance of implant malposition and thus be able to effectively utilize navigation for accurate implant placement.
引用
收藏
页码:299 / 307
页数:9
相关论文
共 50 条
  • [1] Patient Specific Instruments and Patient Individual Implants-A Narrative Review
    Benignus, Christian
    Buschner, Peter
    Meier, Malin Kristin
    Wilken, Frauke
    Rieger, Johannes
    Beckmann, Johannes
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (03):
  • [2] How to avoid errors when quantifying thermal environments
    Bakken, George S.
    Angilletta, Michael J., Jr.
    FUNCTIONAL ECOLOGY, 2014, 28 (01) : 96 - 107
  • [3] SUB-FREEZING REFRIGERATION - HOW TO AVOID ERRORS WHEN USING CRYOSCOPE
    LIGUGNANA, R
    LATTE, 1979, 4 (11-1): : 1576 - 1577
  • [4] Methods of Topical Administration of Drugs and Biological Active Substances for Dental Implants-A Narrative Review
    Wychowanski, Piotr
    Starzynska, Anna
    Adamska, Paulina
    Slupecka-Ziemilska, Monika
    Sobocki, Bartosz Kamil
    Chmielewska, Agnieszka
    Wysocki, Bartlomiej
    Alterio, Daniela
    Marvaso, Giulia
    Jereczek-Fossa, Barbara Alicja
    Kowalski, Jan
    ANTIBIOTICS-BASEL, 2021, 10 (08):
  • [5] Avoid Preanalytical Errors When Using Urine Biomarkers of Exposure
    Jakobsson, Kristina
    d'Errico, Anthonio
    Kromhout, Hans
    Lindh, Christian
    Lundh, Thomas
    Monge, Esteban Arias
    Peraza, Sandra
    Wegman, David
    Wesseling, Ineke
    KIDNEY INTERNATIONAL REPORTS, 2025, 10 (01): : 281 - 281
  • [6] How to avoid singularity when using Euler angles?
    Singla, P
    Mortari, D
    Junkins, JL
    Spaceflight Mechanics 2004, Vol 119, Pt 1-3, 2005, 119 : 1409 - 1426
  • [7] Mistakes in managing hepatocellular carcinoma and how to avoid them: a narrative review
    Niriella, Madunil Anuk
    Dassanayake, Uditha
    de Silva, H. Janaka
    EXPERT REVIEW OF GASTROENTEROLOGY & HEPATOLOGY, 2023, 17 (09) : 913 - 919
  • [8] Response to Avoid Preclinical Errors When Using Urine Biomarkers of Exposure
    Stem, Arthur D.
    Brindley, Stephen
    Rogers, Keegan L.
    Salih, Adil
    Roncal-Jimenez, Carlos A.
    Johnson, Richard J.
    Newman, Lee S.
    Butler-Dawson, Jaime
    Krisher, Lyndsay
    Brown, Jared M.
    KIDNEY INTERNATIONAL REPORTS, 2025, 10 (01): : 281 - 283
  • [9] HOW TO AVOID PITTING WHEN USING TITANIUM ANODIZING RACKS
    HENSCHEL, F
    INDUSTRIAL FINISHING, 1983, 59 (03): : 31 - 31
  • [10] How to avoid problems when using commercial purging compounds
    Mitchell, N. (nmitchell@dynapurge.com), 1600, Gardner Business Media Inc. (60):