Effects of tracer position on screw placement technique in robot-assisted posterior spine surgery: a case-control study

被引:5
|
作者
Yi, Meng [1 ]
Song, Jipeng [1 ]
Zhang, Yao [1 ]
Lin, Wancheng [1 ]
Yao, Mingtao [1 ]
Fan, Yuyu [1 ]
Ding, Lixiang [1 ]
机构
[1] Capital Med Univ, Beijing Shijitan Hosp, Dept Spine, 10 Tieyi Rd, Beijing 100038, Peoples R China
关键词
Robot-assisted posterior spine surgery; Screw Accuracy; Tracer Location; PEDICLE SCREW; ACCURACY; EXPERIENCE; GUIDANCE; LUMBAR; FUSION;
D O I
10.1186/s12891-023-06547-y
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
IntroductionRobot-assisted spine surgery is increasingly used in clinical work, and the installation of tracers as a key step in robotic surgery has rarely been studied.ObjectiveTo explore the potential effects of tracers on surgical outcomes in robot-assisted posterior spine surgery.MethodsWe reviewed all patients who underwent robotic-assisted posterior spine surgery at Beijing Shijitan Hospital over a 2-year period from September 2020 to September 2022. Patients were divided into two groups based on the location of the tracer (iliac spine or vertebral spinous process) during robotic surgery and a case-control study was conducted to determine the potential impact of tracer location on the surgical procedure. Data analysis was performed using SPSS.25 statistical software (SPSS Inc., Chicago, Illinois).ResultsA total of 525 pedicle screws placed in 92 robot-assisted surgeries were analyzed. The rate of perfect screw positioning was 94.9% in all patients who underwent robot-assisted spine surgery (498/525). After grouping studies based on the location of tracers, we found there was no significant difference in age, sex, height and body weight between the two groups. The screw accuracy (p < 0.01)was significantly higher in the spinous process group compared to the iliac group (97.5% versus 92.6%), but the operation time (p = 0.09) was longer in comparison.ConclusionPlacing the tracer on the spinous process as opposed to the iliac spine may result in longer procedure duration or increased bleeding, but enhanced satisfaction of screw placement.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Effects of tracer position on screw placement technique in robot-assisted posterior spine surgery: a case–control study
    Meng Yi
    Jipeng Song
    Yao Zhang
    Wancheng Lin
    Mingtao Yao
    Yuyu Fan
    Lixiang Ding
    BMC Musculoskeletal Disorders, 24
  • [2] Commentary on "Risk Factors of Unsatisfactory Robot-Assisted Pedicle Screw Placement: A Case-Control Study"
    Lee, Jun Ho
    NEUROSPINE, 2021, 18 (04) : 845 - 846
  • [3] Accuracy and risk factors of Magerl screw placement in robot-assisted atlantoaxial surgery: A case series study
    Wu, Jiayuan
    Wei, Yi
    Duan, Fangfang
    He, Da
    Jiang, Xieyuan
    Tian, Wei
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2024, 20 (01):
  • [4] Risk Factors of Unsatisfactory Robot- Assisted Pedicle Screw Placement A Case-Control Study
    Zhang, Qi
    Fan, Ming-Xing
    Han, Xiao-Guang
    Liu, Ya-Jun
    He, Da
    Liu, Bo
    Tian, Wei
    NEUROSPINE, 2021, 18 (04) : 839 - 844
  • [5] Factors Affecting the Accuracy of Pedicle Screw Placement in Robot-Assisted Surgery A Multicenter Study
    Toossi, Nader
    Vardiman, Arnold B.
    Benech, Carlo A.
    Kanaly, Charles W.
    Maltenfort, Mitchell G.
    Backes, Danielle M.
    Bucklen, Brandon
    SPINE, 2022, 47 (23) : 1613 - 1619
  • [6] Learning Curve for Robot-Assisted Percutaneous Pedicle Screw Placement in Thoracolumbar Surgery
    Kam, Jeremy K. T.
    Gan, Calvin
    Dimou, Stefan
    Awad, Mohammed
    Kavar, Bhadu
    Nair, Girish
    Morokoff, Andrew
    ASIAN SPINE JOURNAL, 2019, 13 (06) : 920 - 927
  • [7] Comparison of robot-assisted and freehand pedicle screw placement for lumbar revision surgery
    Jia-Nan Zhang
    Yong Fan
    Xin He
    Tuan-Jiang Liu
    Ding-Jun Hao
    International Orthopaedics, 2021, 45 : 1531 - 1538
  • [8] Comparison of robot-assisted and freehand pedicle screw placement for lumbar revision surgery
    Zhang, Jia-Nan
    Fan, Yong
    He, Xin
    Liu, Tuan-Jiang
    Hao, Ding-Jun
    INTERNATIONAL ORTHOPAEDICS, 2021, 45 (06) : 1531 - 1538
  • [9] Accuracy and safety of robot-assisted cortical bone trajectory screw placement: a comparison of robot-assisted technique with fluoroscopy-assisted approach
    Li, Yue
    Chen, Long
    Liu, Yuzeng
    Ding, Hongtao
    Lu, Hongyi
    Pan, Aixing
    Zhang, Xinuo
    Hai, Yong
    Guan, Li
    BMC MUSCULOSKELETAL DISORDERS, 2022, 23 (01)
  • [10] Accuracy and safety of robot-assisted cortical bone trajectory screw placement: a comparison of robot-assisted technique with fluoroscopy-assisted approach
    Yue Li
    Long Chen
    Yuzeng Liu
    Hongtao Ding
    Hongyi Lu
    Aixing Pan
    Xinuo Zhang
    Yong Hai
    Li Guan
    BMC Musculoskeletal Disorders, 23