Experimental investigation of structural failure during the cooling phase of a fire: Timber columns

被引:12
|
作者
Gernay, Thomas [1 ]
Zehfuss, Jochen [2 ]
Brunkhorst, Sven [2 ]
Robert, Fabienne [3 ]
Bamonte, Patrick [4 ]
McNamee, Robert [5 ,6 ]
Mohaine, Siyimane [3 ]
Franssen, Jean-Marc [7 ]
机构
[1] Johns Hopkins Univ, Baltimore, MD 21218 USA
[2] Tech Univ Braunschweig iBMB, Braunschweig, Germany
[3] CERIB Fire Testing Ctr, Epernon, France
[4] Politecn Milan, Milan, Italy
[5] RISE Res Inst Sweden, Lund, Sweden
[6] Lund Univ, Lund, Sweden
[7] Univ Liege, Liege, Belgium
关键词
burnout resistance; cooling phase; fire resistance; glued laminated; structural failure; timber columns; RESISTANCE; MEMBERS;
D O I
10.1002/fam.3110
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper describes fire tests on loaded glued laminated timber columns in which the structural response was measured during the heating and cooling phases. Identical columns with 280 x 280 mm(2) cross-section and 3.7 m length were tested under various heating durations in a standard furnace to investigate integrity to full burnout. Two of the columns were subjected to ISO 834 heating until failure and their measured fire resistance was 55 and 58 min, respectively. Two columns were subjected to 15 min of ISO 834 heating followed by controlled cooling; these columns failed during the cooling phase, respectively after 98 and 153 min. Flame self-extinction occurred after approximately 40 min while smoldering continued locally. Two columns tested under 10 min of ISO 834 heating both survived the defined heating-cooling exposure. Thermocouples inside the columns show sustained temperature increases for hours after the end of the heating phase. These full-scale furnace experiments show that timber columns may fail during the cooling phase after exposure to standard heating for about 25% of the standard fire resistance duration. These results, in line with previous numerical predictions, highlight the need for further investigation into fire safety until full burnout for timber structures.
引用
收藏
页码:445 / 460
页数:16
相关论文
共 50 条
  • [1] Experimental investigation of structural failure during the cooling phase of a fire: Concrete columns
    Gernay, Thomas
    Franssen, Jean-Marc
    Robert, Fabienne
    McNamee, Robert
    Felicetti, Roberto
    Bamonte, Patrick
    Brunkhorst, Sven
    Mohaine, Siyimane
    Zehfuss, Jochen
    FIRE SAFETY JOURNAL, 2022, 134
  • [2] Collapse of concrete columns during and after the cooling phase of a fire
    Dimia, Mohamed Salah
    Guenfoud, Mohamed
    Gernay, Thomas
    Franssen, Jean-Marc
    JOURNAL OF FIRE PROTECTION ENGINEERING, 2011, 21 (04) : 245 - 263
  • [3] Fire performance, including the cooling phase, of structural glued laminated timber beams
    Kinjo, H.
    Hirashima, T.
    Yusa, S.
    Horio, T.
    Matsumoto, T.
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2016, 7 (04) : 349 - 364
  • [4] The treatment of strain reversal in structural members during the cooling phase of a fire
    ElRimawi, JA
    Burgess, IW
    Plank, RJ
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 1996, 37 (02) : 115 - 135
  • [5] Experimental investigation on ferritic stainless steel columns in fire
    Tondini, Nicola
    Rossi, Barbara
    Franssen, Jean-Marc
    FIRE SAFETY JOURNAL, 2013, 62 : 238 - 248
  • [6] Experimental Investigation of Axial Compression in Composite Strengthened Historical Timber Columns
    Siha, A.
    Zhou, Changdong
    INTERNATIONAL JOURNAL OF ARCHITECTURAL HERITAGE, 2023, 17 (09) : 1428 - 1445
  • [7] Deflection Behavior and Load-Bearing-Period of Structural Glued Laminated Timber Beams in Fire Including Cooling Phase
    Katakura, Yusuke
    Kinjo, Hitoshi
    Hirashima, Takeo
    Yusa, Shuitsu
    Saito, Kiyoshi
    STRUCTURES IN FIRE, 2016, : 667 - 674
  • [8] Deflection behavior and load-bearing period of structural glued laminated timber beams in fire including cooling phase
    Kinjo, Hitoshi
    Katakura, Yusuke
    Hirashima, Takeo
    Yusa, Shuitsu
    Saito, Kiyoshi
    JOURNAL OF STRUCTURAL FIRE ENGINEERING, 2018, 9 (04) : 287 - 299
  • [9] Experimental investigation on fire resistance of CFST columns after earthquake
    Tan, Jike
    Wang, Yuhang
    Tang, Qi
    Wang, Weiyong
    Su, Meini
    ce/papers, 2021, 4 (2-4) : 1483 - 1487
  • [10] The cooling phase, a key factor in the post-fire performance of RC columns
    Molkens, Tom
    FIRE SAFETY JOURNAL, 2022, 128