Analysis of Individual V•O2max Responses during a Cardiopulmonary Exercise Test and the Verification Phase in Physically Active Women

被引:1
|
作者
Succi, Pasquale J. [1 ]
Benitez, Brian [1 ]
Kwak, Minyoung [1 ]
Bergstrom, Haley C. [1 ]
机构
[1] Univ Kentucky, Dept Kinesiol & Hlth Promot, Lexington, KY 40536 USA
关键词
exercise test; women; verification phase; oxygen consumption; MAXIMAL OXYGEN-UPTAKE; O-2; UPTAKE; RELIABILITY; SUITABILITY; ATTAINMENT; CRITERIA; CONFIRM;
D O I
10.3390/jfmk8030124
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
This study aimed to investigate the test-retest reliability, mean, and individual responses in the measurement of maximal oxygen consumption ((VO2max)-O-center dot) during a cardiopulmonary exercise test (CPET) and the verification phase during cycle ergometry in women. Nine women (22 +/- 2 yrs, 166.0 +/- 4.5 cm, 58.6 +/- 7.7 kg) completed a CPET, passively rested for 5 min, and then completed a verification phase at 90% of peak power output to determine the highest (VO2)-O-center dot from the CPET ((VO2CPET)-O-center dot) and verification phase ((VO2verification)-O-center dot) on 2 separate days. Analyses included a two-way repeated measures ANOVA, intraclass correlation coefficients (ICC2,1), standard errors of the measurement (SEM), minimal differences (MD), and coefficients of variation (CoV). There was no test (test 1 versus test 2) x method (CPET vs. verification phase) interaction (p = 0.896) and no main effect for method (p = 0.459). However, test 1 (39.2 mL<middle dot>kg(-1)<middle dot>min(-1)) was significantly higher than test 2 (38.3 mL<middle dot>kg(-1)<middle dot>min(-1)) (p = 0.043). The (VO2CPET)-O-center dot (ICC = 0.984; CoV = 1.98%; SEM = 0.77 mL<middle dot>kg(-1)<middle dot>min(-1); MD = 2.14 mL<middle dot>kg(-1)<middle dot>min(-1)) and (VO2verification)-O-center dot (ICC = 0.964; CoV = 3.30%; SEM = 1.27 mL<middle dot>kg(-1)<middle dot>min(-1); MD = 3.52 mL<middle dot>kg(-1)<middle dot>min(-1)) demonstrated "excellent" reliability. Two subjects demonstrated a test 1 (VO2CPET)-O-center dot that exceeded the test 2 (VO2CPET)-O-center dot, and one subject demonstrated a test 1 (VO2verification)-O-center dot that exceeded the test 2 (VO2verification)-O-center dot by more than the respective CPET and verification phase MD. One subject demonstrated a (VO2CPET)-O-center dot that exceeded the (VO2verification)-O-center dot, and one subject demonstrated a (VO2verification)-O-center dot that exceeded the (VO2CPET)-O-center dot by more than the MD. These results demonstrate the importance of examining the individual responses in the measurement of the (VO2max)-O-center dot and suggest that the MD may be a useful threshold to quantify real individual changes in (VO2)-O-center dot.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Importance of a verification test to accurately assess V?O2max in unfit individuals with obesity
    Moreno-Cabanas, Alfonso
    Ortega, Juan F.
    Morales-Palomo, Felix
    Ramirez-Jimenez, Miguel
    Mora-Rodriguez, Ricardo
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2020, 30 (03) : 583 - 590
  • [2] Verification Phase Confirms V?O2max in a Hot Environment in Sedentary Untrained Males
    Pryor, J. Luke
    Lao, Peter
    Leija, Robert G.
    Perez, Sergio
    Morales, Jacobo
    Looney, David P.
    Cochrane-Snyman, Kristen C.
    MEDICINE & SCIENCE IN SPORTS & EXERCISE, 2023, 55 (06) : 1069 - 1075
  • [3] Cardiopulmonary exercise testing with supramaximal verification produces a safe and valid assessment of <(V)over dot>O2max in people with cystic fibrosis: a retrospective analysis
    Causer, Adam J.
    Shute, Janis K.
    Cummings, Michael H.
    Shepherd, Anthony, I
    Bright, Victoria
    Connett, Gary
    Allenby, Mark, I
    Carroll, Mary P.
    Daniels, Thomas
    Saynor, Zoe L.
    JOURNAL OF APPLIED PHYSIOLOGY, 2018, 125 (04) : 1277 - 1283
  • [4] The effects of exercise modality on the incidence of plateau at V•O2max
    Gordon, Dan
    Mehter, Mashihullah
    Gernigon, Marie
    Caddy, Oliver
    Keiller, Don
    Barnes, Richard
    CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2012, 32 (05) : 394 - 399
  • [5] <(V)over dot>O2MAX VERIFICATION TRIAL: THE ILLUSION OF A "TRUE" MEASURE?
    Pogliaghi, S.
    Paterson, D. H.
    Murias, J. M.
    JOURNAL OF APPLIED PHYSIOLOGY, 2018, 125 (03) : 967 - 967
  • [6] Running economy deteriorates following 60 min of exercise at 80% V˙O2max
    John Sproule
    European Journal of Applied Physiology and Occupational Physiology, 1998, 77 : 366 - 371
  • [7] Which exercise prescriptions optimize (V) over dot O2max during cancer treatment?-A systematic review and meta-analysis
    Bjorke, Ann Christin Helgesen
    Sweegers, Maike G.
    Buffart, Laurien M.
    Raastad, Truls
    Nygren, Peter
    Berntsen, Sveinung
    SCANDINAVIAN JOURNAL OF MEDICINE & SCIENCE IN SPORTS, 2019, 29 (09) : 1274 - 1287
  • [8] Effects of chronic nitric oxide synthase inhibition on V'O2max and exercise capacity in mice
    Wojewoda, M.
    Przyborowski, K.
    Sitek, B.
    Zakrzewska, A.
    Mateuszuk, L.
    Zoladz, J. A.
    Chlopicki, S.
    NAUNYN-SCHMIEDEBERGS ARCHIVES OF PHARMACOLOGY, 2017, 390 (03) : 235 - 244
  • [9] Using wearable technology to monitor exercise intensity and predict <(V) over dot>O2max
    Pettitt, Robert W.
    Fretti, Sarah K.
    Kantor, Michael A.
    Gubler, Coral
    MHEALTH, 2021, 7 (02)
  • [10] Effects of chronic nitric oxide synthase inhibition on V’O2max and exercise capacity in mice
    M. Wojewoda
    K. Przyborowski
    B. Sitek
    A. Zakrzewska
    L. Mateuszuk
    J. A. Zoladz
    S. Chlopicki
    Naunyn-Schmiedeberg's Archives of Pharmacology, 2017, 390 : 235 - 244