Simulation study of a heat pump drying system using a solar assisted flash tank vapor injection cycle

被引:10
|
作者
Yu, Jin [1 ,2 ]
Yu, Jianlin [2 ]
机构
[1] Shanghai Jiao Tong Univ, Inst Refrigerat & Cryogen, Shanghai 200240, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Energy & Power Engn, Dept Refrigerat & Cryogen Engn, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
Vapor injection; Heat pump drying system; Direct -expansion solar collector; Air circulation loop; PERFORMANCE ANALYSIS; SCROLL COMPRESSOR; DRYER; EXPERIMENTATION; EXCHANGERS; DESIGN; CO2;
D O I
10.1016/j.solener.2023.01.033
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Heat pumps are widely used in many fields due to their high efficiency and energy saving potential. However, the application of single-stage vapor-compression heat pump dryer is limited due to low drying temperature and the decreasing reliability for high temperature drying. In order to apply heat pump to high temperature drying, a heat pump drying system using a solar assisted flash tank vapor injection cycle (HPDS-SFVIC) is presented. This system allows the solar collector to absorb solar energy at a lower temperature and achieves significant improvement of heating capacity and drying temperature. The effects of component configuration and various operating conditions on the drying system with open, bypass, and closed air circulation loop are evaluated, respectively. The results show that under a typical operating condition, the proposed cycle achieves great performance improvement of 21.8% and 75.8% in both the heating coefficient of performance (COPh) and heating capacity, compared with the conventional cycle. Utilization of solar energy is advantageous to provide higher air temperature for drying. With increased solar radiation intensity and collector area, heating capacity and drying temperature can be improved, while COPh remains constant as 5.0-5.2. When the drying system provides dry air at 65 degrees C stably, it saves 27.8%-41.7% of power consumption, and COPh is improved by 41.2%-62.1% on average.
引用
收藏
页码:223 / 239
页数:17
相关论文
共 50 条
  • [1] Thermodynamic and economic analysis of a solar-assisted ejector-enhanced flash tank vapor injection heat pump cycle with dual evaporators
    Ma, Di
    Chen, Qi
    Yan, Gang
    RENEWABLE ENERGY, 2024, 235
  • [2] Analysis of an ejector-assisted flash tank vapor injection heat pump cycle with dual evaporators for dryer application
    Jing, Siqi
    Chen, Qi
    Yu, Jianlin
    ENERGY, 2024, 286
  • [3] Comparative research on vapor injection heat pump with a novel flash tank
    Sun, Jinfei
    Guo, Jianxiang
    He, Longbin
    Hou, Shengjun
    Yu, Zhengchang
    HELIYON, 2023, 9 (06)
  • [4] Transient modeling of a flash tank vapor injection heat pump system - Part II: Simulation results and experimental validation
    Qiao, Hongtao
    Xu, Xing
    Aute, Vikrant
    Radermacher, Reinhard
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 49 : 183 - 194
  • [5] Simulation Study on the Performance of an Enhanced Vapor-Injection Heat-Pump Drying System
    Dong, Suiju
    Liu, Yin
    Meng, Zhaofeng
    Zhai, Saina
    Hu, Ke
    Zhang, Fan
    Zhou, Dong
    ENERGIES, 2022, 15 (24)
  • [6] Entropic optimization of the economizer's pressure in a heat pump cycle integrated with a flash-tank and vapor-injection system
    Rad, Ehsan Amiri
    Maddah, Saeed
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 97 : 56 - 66
  • [7] Review on the two-stage vapor injection heat pump with a flash tank
    Ceylan, Havva
    ENGINEERING SCIENCE AND TECHNOLOGY-AN INTERNATIONAL JOURNAL-JESTECH, 2023, 48
  • [8] Transient modeling of a flash tank vapor injection heat pump system - Part I: Model development
    Qiao, Hongtao
    Aute, Vikrant
    Radermacher, Reinhard
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2015, 49 : 169 - 182
  • [9] Mushroom drying with solar assisted heat pump system
    Sevik, Seyfi
    Aktas, Mustafa
    Dogan, Hikmet
    Kocak, Saim
    ENERGY CONVERSION AND MANAGEMENT, 2013, 72 : 171 - 178
  • [10] Transient and steady-state experimental investigation of flash tank vapor injection heat pump cycle control strategy
    Xu, Xing
    Hwang, Yunho
    Radermacher, Reinhard
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2011, 34 (08): : 1922 - 1933