Comparison of de novo implantation vs. upgrade cardiac resynchronisation therapy: a multicentre experience

被引:2
|
作者
Zandi, Zahra [1 ]
Eslami, Masoud [2 ]
Kamali, Farzad [1 ]
Teimouri-jervekani, Zahra [3 ]
Taherpour, Mehdi [4 ]
Mollazadeh, Reza [2 ]
Haghjoo, Majid [1 ]
Fazelifar, Amir Farjam [1 ]
Alizadeh, Abolfath [1 ]
Madadi, Shabnam [1 ]
Hosseini Selki Sar, Sajjad [2 ]
Emkanjoo, Zahra [1 ]
机构
[1] Iran Univ Med Sci, Cardiac Electrophysiol Res Ctr, Rajaie Cardiovasc Med & Res Ctr, Tehran, Iran
[2] Univ Tehran Med Sci, Imam Khomeini Hosp Complex, Sch Med, Cardiol Dept, Tehran, Iran
[3] Isfahan Univ Med Sci, Cardiovasc Res Inst, Cardiac Rehabil Res Ctr, Esfahan, Iran
[4] Imam Reza Int Univ, Razavi Hosp, Dept Cardiac Electrophysiol, Mashhad, Iran
关键词
CRT upgrade; cardiac resynchronisation therapy; de novo CRT; heart failure; RESYNCHRONIZATION THERAPY; COMPLICATIONS; PACEMAKER; OUTCOMES;
D O I
10.1080/00015385.2023.2285539
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The clinical safety and consequences of upgrade procedures compared with de novo cardiac resynchronisation therapy (CRT) implantation in heart failure remain unclear. The present study aimed to assess clinical and procedural consequences of patients undergoing CRT upgrade as compared to de novo CRT implantations.Methods: In this prospective cohort study, two subgroups were considered as the study population as (1) de novo group that CRT was considered on optimised medical treatment with heart failure of NYHA functional class from II to IV, left ventricular ejection fraction (LVEF) of <= 35%, and QRS width of >130 ms and (2) upgrade group including the patients with previously implantable cardioverter defibrillator (ICD) with the indications for upgrading to CRT. The two groups were compared regarding the changes in clinical outcome and echocardiography parameters.Results: The procedure was successful in 95.9% of patients who underwent CRT upgrade and 100% of those who underwent de novo CRT implantation. It showed a significant improvement in LVEF, severity of mitral regurgitation and NYHA functional classification, without any difference between the two study groups. Overall procedural related complications were reported in 10.8% and 3.8% (p = .093) and cardiac death in 5.4% and 2.5% (p = .360), respectively, with no overall difference in postoperative outcome between the two groups.Conclusions: Upgrading to CRT is a safe and effective procedure regarding improvement of functional class, left ventricular function status and post-procedural outcome.
引用
收藏
页码:338 / 343
页数:6
相关论文
共 50 条
  • [1] Is there a comparable benefit of cardiac resynchronisation therapy in patients receiving an upgrade vs de novo device?
    Wokhlu, A.
    Webster, T. L.
    Rea, R. F.
    Asirvatham, S. J.
    Shen, W. K.
    Wiste, H. J.
    Hodge, D. O.
    Hayes, D. L.
    Cha, Y. M.
    EUROPEAN HEART JOURNAL, 2008, 29 : 3 - 4
  • [2] De novo implantation vs. upgrade cardiac resynchronization therapy: a systematic review and meta-analysis
    Kosztin, A.
    Vamos, M.
    Aradi, D.
    Schwertner, R.
    Kovacs, A.
    Nagy, K. V.
    Zima, E.
    Geller, L.
    Duray, G.
    Kutyifa, V.
    Merkely, B.
    EUROPEAN HEART JOURNAL, 2017, 38 : 1167 - 1167
  • [3] De novo implantation vs. upgrade cardiac resynchronization therapy: a systematic review and meta-analysis
    Annamaria Kosztin
    Mate Vamos
    Daniel Aradi
    Walter Richard Schwertner
    Attila Kovacs
    Klaudia Vivien Nagy
    Endre Zima
    Laszlo Geller
    Gabor Zoltan Duray
    Valentina Kutyifa
    Bela Merkely
    Heart Failure Reviews, 2018, 23 : 15 - 26
  • [4] De novo implantation vs. upgrade cardiac resynchronization therapy: a systematic review and meta-analysis
    Kosztin, Annamaria
    Vamos, Mate
    Aradi, Daniel
    Schwertner, Walter Richard
    Kovacs, Attila
    Nagy, Klaudia Vivien
    Zima, Endre
    Geller, Laszlo
    Duray, Gabor Zoltan
    Kutyifa, Valentina
    Merkely, Bela
    HEART FAILURE REVIEWS, 2018, 23 (01) : 15 - 26
  • [5] Comparison of de novo versus upgrade cardiac resynchronisation therapy on clinical effect and long-term outcome
    Stassen, Jan
    Scherrenberg, Martijn
    Dilling-Boer, Dagmara
    Vijgen, Johan
    Koopman, Pieter
    Schurmans, Joris
    Herbots, Lieven
    Verwerft, Jan
    Schroyens, Matthew
    Timmermans, Philippe
    ACTA CARDIOLOGICA, 2021, 76 (09) : 993 - 1000
  • [6] Upgrade from implantable cardioverter-defibrillator vs. de novo implantation of cardiac resynchronization therapy: long-term outcomes
    Jedrzejczyk-Patej, Ewa
    Mazurek, Michal
    Kotalczyk, Agnieszka
    Kowalska, Wiktoria
    Konieczny-Kozielska, Aleksandra
    Kozielski, Jonasz
    Podolecki, Tomasz
    Szulik, Mariola
    Sokal, Adam
    Kowalski, Oskar
    Kalarus, Zbigniew
    Sredniawa, Beata
    Lenarczyk, Radoslaw
    EUROPACE, 2021, 23 (01): : 113 - 122
  • [7] Long-term clinical outcome of patients after de novo vs. upgrade cardiac resynchronization therapy: a high volume, single center experience
    Kosztin, A.
    Schwertner, W.
    Bojtar, Z. S.
    Kovacs, A.
    Zima, E.
    Geller, L.
    Kutyifa, V.
    Merkely, B.
    EUROPEAN HEART JOURNAL, 2017, 38 : 1172 - 1172
  • [8] Comparison of De Novo versus Upgrade Cardiac Resynchronization Therapy; Focused on the Upgrade for Pacing-Induced Cardiomyopathy
    Gwag, Hye Bin
    Chun, Kwang Jin
    Hwang, Jin Kyung
    Park, Kyoung-Min
    On, Young Keun
    Kim, June Soo
    Park, Seung-Jung
    YONSEI MEDICAL JOURNAL, 2017, 58 (04) : 703 - 709
  • [9] COMPARISON OF UPGRADED VERSUS DE-NOVO CARDIAC RESYNCHRONISATION THERAPY (CRT) DEVICES ON CARDIOVASCULAR OUTCOMES AND RESPONSE
    McAloon, Christopher
    Heining, Domonic
    Barker, Jethro
    Atherton, Gavin
    Anderson, Benjamin
    Osman, Faizel
    HEART, 2015, 101 : A31 - A32
  • [10] De novo and upgraded cardiac resynchronisation therapy device complications at 1-year
    Brough, C. E. P.
    Mcgee, C.
    Rao, A.
    Wright, D. J.
    EUROPEAN HEART JOURNAL, 2014, 35 : 94 - 94