Effect of hydrogen-enriched natural gas on flue gas waste heat recovery potential and condensing heat exchanger performance

被引:2
|
作者
Mu, Lianbo [1 ]
Wang, Suilin [1 ]
Lu, Junhui [1 ]
Li, Congna [1 ]
Lan, Yuncheng [1 ]
Liu, Guichang [2 ]
Zhang, Tong [3 ]
机构
[1] Beijing Univ Civil Engn & Architecture, Sch Environm & Energy Engn, Beijing 100044, Peoples R China
[2] Dalian Univ Technol, Dept Chem Engn, Dalian 116023, Peoples R China
[3] Xinjiang Qimashan Heating Co Ltd, Urumqi 830063, Peoples R China
关键词
Hydrogen -enriched natural gas; Flue gas; Condensing heat exchanger; Energy saving; Carbon reduction; SAFETY;
D O I
10.1016/j.energy.2023.129591
中图分类号
O414.1 [热力学];
学科分类号
摘要
Hydrogen-enriched natural gas (HENG) is one of the significant ways to store, transport, and utilize hydrogen energy. This paper presents the characteristics of HENG and flue gas, energy saving, carbon reduction, and condensate recovery potential of flue gas waste heat. Based on the theoretical and experimental study of the existing flue gas condensing heat exchanger (FGCHE) added at the rail of gas-fired boiler, the performance of the FGCHE under different hydrogen blending ratios is studied. The results show that augmenting the hydrogen blending ratio decreases the volume heating value of HENG, and CO2 content of flue gas. Meanwhile, the mass heating value of the HENG, the water vapor content, and dew point temperature of flue gas increase as the hydrogen blending ratio increases. The flue gas waste heat recovery utilization ratio and energy-saving efficiency of the FGCHE can be promoted. Moreover, the heat transfer capacity of the FGCHE using HENG is enhanced, while the flue gas flow pressure drop is reduced. Compared with the FGCHE used in pure natural gas systems, the all-hydrogen system increases the flue gas waste heat recovery amount by 62.4-120.4 %, reduces the flue gas flow pressure drop by 33.9 %, and reduces the carbon emission by 100 %.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Thermodynamic and emission characteristics of a hydrogen-enriched natural gas-fired boiler integrated with external flue gas recirculation and waste heat recovery
    Wang, Tiantian
    Liu, Xuemin
    Zhang, Yang
    Zhang, Hai
    APPLIED ENERGY, 2024, 358
  • [2] Synergetic process of condensing heat exchanger and absorption heat pump for waste heat and water recovery from flue gas
    Wang, Xiang
    Zhuo, Jiankun
    Liu, Jianmin
    Li, Shuiqing
    APPLIED ENERGY, 2020, 261
  • [3] Optimization of solution heat exchanger of AHP in flue gas waste heat recovery
    Niu, Yang
    Hua, Jing
    Fan, Hongming
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 477 - 484
  • [4] Hydrogen production by waste heat recovery of hydrogen-enriched compressed natural gas via steam methane reforming process
    Shahid, Muhammad Ihsan
    Farhan, Muhammad
    Rao, Anas
    Hussain, Muhammad Saddam
    Salam, Hamza Ahmad
    Chen, Tianhao
    Zhang, Zhongsen
    Li, Xin
    Ma, Fanhua
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2025, 117 : 374 - 392
  • [5] Effects of Wall Fins Patterns on the Flue Gas Performance of Condensing Heat Exchanger
    Cao, Weixue
    You, Xueyi
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 2281 - 2288
  • [6] High performance heat exchanger for latent heat recovery from flue gas
    Yamashita, Junpei
    Utaka, Yoshio
    Kobayashi, Masakazu
    Sano, Yasuhiro
    Nihon Kikai Gakkai Ronbunshu, B Hen/Transactions of the Japan Society of Mechanical Engineers, Part B, 2013, 79 (803): : 1363 - 1374
  • [7] Heat and mass transfer between flue gas and surface of condensing heat exchanger
    Wang, SL
    Li, LP
    Pan, SY
    Ai, XY
    Fu, ZC
    Zhang, JF
    Wen, Z
    PROCEEDINGS OF THE 4TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATING AND AIR CONDITIONING, VOLS 1 AND 2, 2003, : 777 - 784
  • [8] Recovery the heat in flue gas of heater with heat pipe exchanger
    You Qi Chu Yun/Oil & Gas Storage and Transportation, 1997, 16 (05): : 47 - 49
  • [9] Experimental Analysis of Packed Spraying Heat Exchanger in Waste Heat Recovery From Flue Gas
    Zhu, Xiao-Lei
    Zhang, Lei
    Meng, Ji-An
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2020, 41 (12): : 3061 - 3067
  • [10] CONDENSING HEAT-EXCHANGER CAPTURES FLUE-GAS LATENT-HEAT
    VANHOVEN, E
    POWER, 1984, 128 (02) : 126 - 126