Assessment of patients radiation doses associated with computed tomography coronary angiography

被引:2
|
作者
Salah, H. [1 ,2 ]
Tamam, Nissren [3 ]
Rabbaa, Mohammad [4 ]
Abuljoud, Mohammad [4 ]
Zailae, Ali [6 ]
Alkhorayef [7 ]
Abuhadi, N. [10 ]
Elshami, W. [9 ]
Sulieman, A. [5 ]
Bradley, D. A. [8 ,11 ]
机构
[1] INAYA Med Coll, Dept Nucl Med, Riyadh, Saudi Arabia
[2] Sudan Univ Sci & Technol, Coll Med Radiol Sci, Khartoum, Sudan
[3] Princess Nourah Bint Abdulrahman Univ, Dept Phys, Coll Sci, POB 84428, Riyadh 11671, Saudi Arabia
[4] Riyadh Care Hosp, Dept Radiol, Riyadh, Saudi Arabia
[5] Prince Sattam Bin Abdulaziz Univ, Radiol & Med Imaging Dept, Coll Appl Med Sci, Alkharj, Saudi Arabia
[6] Minist Hlth, Riyadh, Saudi Arabia
[7] King Saud Univ, Dept Radiol Sci, Coll Appl Med Sci, Riyadh, Saudi Arabia
[8] Univ Surrey, Dept Phys, Ctr Nucl & Radiat Phys, Guildford, Surrey, England
[9] Univ Sharjah, Med Diagnost Imaging Dept, Coll Hlth Sci, Sharjah, U Arab Emirates
[10] Jazan Univ, Diagnot Radiog Technol Dept, Coll Appl Med Sci, Jazan, Saudi Arabia
[11] Sunway Univ, Inst Hlth Care Dev, Jalan Univ, Subang Jaya 46150, PJ, Malaysia
关键词
CT angiography; Radiation risk; Effective dose; LENGTH PRODUCT; CT;
D O I
10.1016/j.apradiso.2022.110548
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Computed tomography coronary angiography (CTCA) has generated tremendous interest over the past 20 years by using multidetector computed tomography (MDCT) because of its high diagnostic accuracy and efficacy in assessing patients with coronary artery disease. This technique is related to high radiation doses, which has raised serious concerns in the literature. Effective dose (E, mSv) may be a single parameter meant to reflect the relative risk from radiation exposure. Therefore, it is necessary to calculate this quantity to point to relative radiation risk. The objectives of this study are to evaluate patients??? exposure during diagnostic CCTA procedures and to estimate the risks. Seven hundred ninety patients were estimated during three successive years. The patient???s exposure was estimated based on a CT device???s delivered radiation dose (Siemens Somatom Sensation 64 (64-MDCT)). The participating physicians obtained the parameters relevant to the radiation dose from the scan protocol generated by the CT system after each CCTA study. The parameters included the volume CT dose index (CTDIvol, mGy) and dose length product (DLP, mGy ?? cm). The mean and range of CTDIvol (mGy) and DLP (mGy ?? cm) for three respective year was (2018):10.8 (1.14???77.7) and 2369.8 ?? 1231.4 (290.4???6188.9), (2019): 13.82 (1.13???348.5), and 2180.5 (501.8???9534.5) and (2020) 10.9 (0.7???52.9) and 1877.3 (149.4???5011.1), respectively. Patients??? effective doses were higher compared to previous studies. Therefore, the CT acquisition parameter optimization is vital to reduce the dose to its minimal value.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Radiation Doses Associated With Cardiac Computed Tomography Angiography
    Daher, Iyad N.
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (22): : 2324 - 2324
  • [2] Radiation Doses Associated With Cardiac Computed Tomography Angiography Reply
    Hausleiter, Joerg
    Gerber, Thomas C.
    Achenbach, Stephan
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2009, 301 (22): : 2325 - 2325
  • [3] Comparison of radiation doses from multislice computed tomography coronary angiography and conventional diagnostic angiography
    Coles, DR
    Smail, MA
    Negus, IS
    Wilde, P
    Oberhoff, M
    Karsch, KR
    Baumbach, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (09) : 1840 - 1845
  • [4] Assessment of Radiation doses to Paediatric Patients in Computed Tomography Procedures
    Alzimami, Khalid
    POLISH JOURNAL OF RADIOLOGY, 2014, 79 : 344 - 348
  • [5] Assessment of Coronary Atherosclerosis in Patients With Familial Hypercholesterolemia by Coronary Computed Tomography Angiography
    Tada, Hayato
    Kawashiri, Masa-aki
    Okada, Hirofumi
    Teramoto, Ryota
    Konno, Tetsuo
    Yoshimuta, Tsuyoshi
    Sakata, Kenji
    Nohara, Atsushi
    Inazu, Akihiro
    Kobayashi, Junji
    Mabuchi, Hiroshi
    Yamagishi, Masakazu
    Hayashi, Kenshi
    AMERICAN JOURNAL OF CARDIOLOGY, 2015, 115 (06): : 724 - 729
  • [6] Chest Circumference as a Predictive Parameter of Computed Tomography Coronary Angiography Radiation Doses from Dual-Source Computed Tomography
    Sagsoz, M. Erdem
    Bayraktutan, Ummugulsum
    Ogul, Hayri
    Kantarci, Mecit
    EURASIAN JOURNAL OF MEDICINE, 2013, 45 (01): : 43 - 46
  • [7] Temporal trends in personal radiation dose associated with coronary computed tomography angiography
    Marraccini, P.
    Mazzarisi, A.
    Carpeggiani, C.
    Schlueter, M.
    Paolicchi, F.
    Bianchi, M.
    Faggioni, L.
    Coppini, G.
    Bartolozzi, C.
    Picano, E.
    EUROPEAN HEART JOURNAL, 2013, 34 : 970 - 970
  • [8] Computed tomography coronary angiography in asymptomatic patients
    Maffei, E.
    Palumbo, A.
    Martini, C.
    Tedeschi, C.
    Arcadi, T.
    La Grutta, L.
    Malago, R.
    Weustink, A. C.
    Mollet, N. R.
    De Rosa, R.
    Catalano, O.
    Salamone, I.
    Blandino, A.
    Midiri, M.
    Cademartiri, F.
    RADIOLOGIA MEDICA, 2011, 116 (08): : 1161 - 1173
  • [9] Computed Tomography Coronary Angiography in Hemodialysis Patients
    Sugaya, Teppei
    Yamaguchi, Takayoshi
    Furuya, Jungo
    Igarashi, Yasuni
    Igarashi, Keiichi
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 105 (9A): : 57B - 57B
  • [10] Coronary computed tomography angiography for the assessment of SYNTAX score
    Wolny, Rafal
    Jastrzebski, Jan
    Szubielski, Michal
    Pregowski, Jerzy
    Danielski, Pawel
    Kochanowski, Lukasz
    Kepka, Cezary
    Karcz, Maciej
    Chmielak, Zbigniew
    Witkowski, Adam
    KARDIOLOGIA POLSKA, 2016, 74 (01) : 40 - 46