Synergetic control for three-level voltage source inverter-based shunt active power filter to improve power quality

被引:17
|
作者
Deffaf, Brahim [1 ]
Farid, Hamoudi [1 ]
Benbouhenni, Habib [2 ]
Medjmadj, Slimane [3 ,4 ]
Debdouche, Naamane [5 ]
机构
[1] Univ Bejaia, Fac Technol, Lab Maitrise Energies Renouvelables LMER, Bejaia 06000, Algeria
[2] Nisantasi Univ, Fac Engn & Architecture, Dept Elect & Elect Engn, Istanbul, Turkiye
[3] Univ Set, Lab Control, Setif, Algeria
[4] Univ Bordj Bou Arreridj, El Anceur, Algeria
[5] Univ Freres Mentouri Constantine 1, Lab Electrotech Constantine LEC, Constantine, Algeria
关键词
Three levels neutral point clamped; Synergetic control; Power quality; Shunt active power filter; Proportional-integral controller; SPACE-VECTOR MODULATION; SLIDING MODE CONTROL; PWM; SYSTEMS; IMPLEMENTATION; OPTIMIZATION; ELIMINATION; DESIGN;
D O I
10.1016/j.egyr.2023.07.051
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
The present paper proposes a synergetic control (SC) with Phase-Locked Loop (PLL) technique for a three-phase three-levels neutral point clamped-voltage source inverter-based shunt active power filter (SAPF). This one is devoted to compensating for nonlinear load harmonics and reactive power to improve power quality in distribution power systems. SC strategy is known as a robust control with good performances in transient and steady-state performance. Furthermore, it does not require solving the state equations, nor knowing the poles of the system. The DC voltage, as well as the active filter currents, are controlled using SC strategies. The efficiency of the suggested strategy has been verified through simulation tests using Matlab/Simulink software, where the simulation results are analyzed for two scenarios: a diode bridge rectifier with RL load and RC load. The active power filter demonstrated outstanding performance in reducing harmonics, maintaining a dynamic response, and tracking DC voltage for both RL and RC loads, as revealed by the simulation results. By comparing the suggested control with the traditional control, we found that the former outperforms the latter in all aspects. This sheds light on the effectiveness of the suggested control. & COPY; 2023 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:1013 / 1027
页数:15
相关论文
共 50 条
  • [1] Three-level voltage-source inverter for shunt active filter
    Lin, BR
    Yang, TY
    IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2004, 151 (06): : 744 - 751
  • [2] Three-Phase Three-Level Inverter Based Shunt Active Power Filter
    Altin, Necmi
    Kaplan, Orhan
    Ozdemir, Saban
    2014 16TH INTERNATIONAL POWER ELECTRONICS AND MOTION CONTROL CONFERENCE AND EXPOSITION (PEMC), 2014, : 799 - 804
  • [3] Neutral-point voltage deviation control for three-level inverter-based shunt active power filter with fuzzy-based dwell time allocation
    Hoon, Yap
    Radzi, Mohd Amran Mohd
    Hassan, Mohd Khair
    Mailah, Nashiren Farzilah
    IET POWER ELECTRONICS, 2017, 10 (04) : 429 - 441
  • [4] An active power filter implemented with a three-level NPC voltage-source inverter
    Aburto, V
    Schneider, M
    Moran, L
    Dixon, J
    PESC'97: 28TH ANNUAL IEEE POWER ELECTRONICS SPECIALISTS CONFERENCE - RECORD, VOLS I AND II, 1997, : 1121 - 1126
  • [5] Cascaded Three-level Inverter based Shunt Active Filter for Power Conditioning Application
    Patnaik, Sushree Sangita
    Panda, Anup Kumar
    2013 ANNUAL IEEE INDIA CONFERENCE (INDICON), 2013,
  • [6] DC-Link Capacitor Voltage Regulation for Three-Phase Three-Level Inverter-Based Shunt Active Power Filter with Inverted Error Deviation Control
    Hoon, Yap
    Radzi, Mohd Amran Mohd
    Hassan, Mohd Khair
    Mailah, Nashiren Farzilah
    ENERGIES, 2016, 9 (07)
  • [7] Operation of Three-Level Inverter-Based Shunt Active Power Filter Under Nonideal Grid Voltage Conditions With Dual Fundamental Component Extraction
    Hoon, Yap
    Radzi, Mohd Amran Mohd
    Hassan, Mohd Khair
    Mailah, Nashiren Farzilah
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (09) : 7558 - 7570
  • [8] Instantaneous active and reactive current control technique of shunt active power filter based on the three-level NPC inverter
    Pouresmaeil, Edris
    Montesinos-Miracle, Daniel
    Gomis-Bellmunt, Oriol
    Sudria-Andreu, Antoni
    EUROPEAN TRANSACTIONS ON ELECTRICAL POWER, 2011, 21 (07): : 2007 - 2022
  • [9] Three-Level Inverter-Based Shunt Active Power Filter in Three-Phase Three-Wire and Four-Wire Systems
    Vodyakho, Oleg
    Mi, Chris C.
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2009, 24 (5-6) : 1350 - 1363
  • [10] A Dual-Function Instantaneous Power Theory for Operation of Three-Level Neutral-Point-Clamped Inverter-Based Shunt Active Power Filter
    Hoon, Yap
    Radzi, Mohd Amran Mohd
    Hassan, Mohd Khair
    Mailah, Nashiren Farzilah
    ENERGIES, 2018, 11 (06):