共 50 条
CLinical Assessment of WEB device in Ruptured aneurYSms (CLARYS): 12-month angiographic results of a multicenter study
被引:16
|作者:
Spelle, Laurent
[1
,2
]
Herbreteau, Denis
[3
]
Caroff, Jildaz
[1
,4
]
Barreau, Xavier
[5
]
Ferre, Jean-Christophe
[6
]
Fiehler, Jens
[7
]
Januel, Anne-Christine
[8
]
Costalat, Vincent
[9
]
Liebig, Thomas
[10
]
Bourcier, Romain
[11
]
Moehlenbruch, Markus A.
[12
]
Berkefeld, Joachim
[13
]
Weber, Werner
[14
]
Mihalea, Cristian
[1
,4
]
Ikka, Leon
[1
,4
]
Ozanne, Augustin
[1
,4
]
Cognard, Christophe
[8
]
Narata, Ana Paula
[3
]
Bibi, Richard Edwige
[3
]
Gauvrit, Jean-Yves
[6
]
Raoult, Helene
[6
]
Velasco, Stephane
[15
]
Buhk, Jan-Hendrik
[16
]
Chalumeau, Vanessa
[1
,4
]
Bester, Maxim
[7
]
Desal, Hubert
[11
]
de Rochemont, Richard du Mesnil
[13
]
Bohner, Georg
[17
]
Fischer, Sebastian
[14
]
Gallas, Sophie
[1
,4
]
Biondi, Alessandra
[18
]
Grimaldi, Lamiae
[19
,20
]
Moret, Jacques
[1
,2
]
Byrne, James
[21
]
Pierot, Laurent
[22
,23
]
机构:
[1] Bicetre Univ Hosp, Intervent Neuroradiol, NEURI Brain Vasc Ctr, Le Kremlin Bicetre, France
[2] Paris Saclay Univ, Fac Med, Le Kremlin Bicetre, France
[3] Reg Univ Hosp, Dept Intervent Neuroradiol, Tours, France
[4] AP HP, Paris, France
[5] Pellegrin Univ Hosp, Dept Neuroradiol, Bordeaux, France
[6] Reg Univ Hosp, Dept Neuroradiol, Rennes, France
[7] Univ Med Ctr Hamburg Eppendorf, Dept Diagnost & Intervent Neuroradiol, Hamburg, Germany
[8] Hop Pierre Paul Riquet, Dept Diagnost & Therapeut Neuroradiol, Toulouse, France
[9] Hop Gui de Chauliac, Dept Neuroradiol, Montpellier, France
[10] Ludwig Maximilians Univ Munchen, Munich Fac Med, Dept Neuroradiol, Munich, Germany
[11] Reg Univ Hosp, Dept Neuroradiol, Nantes, France
[12] Univ Klinikum Heidelberg, Dept Neuroradiol, Heidelberg, Germany
[13] Klinikum Johann Wolfgang Goethe Univ Frankfurt, Inst Neuroradiol, Frankfurt, Germany
[14] Ruhr Univ Bochum, Med Fak, Dept Neuroradiol, Bochum, Germany
[15] Reg Univ Hosp, Dept Radiol, Poitiers, France
[16] Asklepios Hosp Grp, Dept Neuroradiol, Hamburg, Germany
[17] Charite, Neuroradiol, Berlin, Germany
[18] Jean Minjoz Univ Hosp, Dept Neuroradiol & Endovasc Therapy, Besancon, France
[19] Paris Saclay Univ, AP HP, Fac Med, Clin Res Unit, Le Kremlin Bicetre, France
[20] Univ Versailles St Quentin en Yvelines UFR Sci, CESP Antiinfect Evas & Pharmacoepidemiol Team, Montigny Le Bretonneux, France
[21] Oxford Radcliffe Hosp NHS Trust, Dept Neuroradiol, Oxford, England
[22] Hop Maison Blanche, Dept Neuroradiol, Reims, France
[23] Champagne Ardenne Univ, Reims, France
关键词:
Aneurysm;
Angiography;
Device;
Intervention;
Subarachnoid;
INTRACRANIAL ANEURYSMS;
SUBARACHNOID HEMORRHAGE;
COILING;
SAFETY;
D O I:
10.1136/neurintsurg-2022-018749
中图分类号:
R445 [影像诊断学];
学科分类号:
100207 ;
摘要:
Background The CLinical Assessment of WEB device in Ruptured aneurYSms (CLARYS) study has shown that the endovascular treatment of ruptured bifurcation aneurysms with the Woven EndoBridge (WEB) is safe and effective and provides protection against rebleeding at 1 month and 1 year. The 12-month angiographic follow-up is an important endpoint of the study. Methods The CLARYS study is a prospective multicenter study conducted in 13 European centers. The study enrolled 60 patients with 60 ruptured aneurysms of the anterior and posterior circulation. The study was conducted with an independent assessment of safety outcomes and imaging. Results Sixty patients with 60 ruptured bifurcation aneurysms to be treated with the WEB were included. Fifty-three aneurysms (88.3%) had a broad base with a dome to neck ratio <2 (mean 1.6). Of these, 46 patients were evaluated by an independent core laboratory with follow-up imaging performed at 12 months or before eventual retreatment. At 1 year, 19/46 aneurysms (41.3%) were completely occluded (Raymond-Roy grade I), 21/46 (45.7%) had a residual neck and 6/46 (13.0%) had residual aneurysm filling. Adequate occlusion was reported in 40/46 (87%) aneurysms. Six patients underwent target aneurysm retreatment. Conclusions The CLARYS study has previously shown that the use of the WEB in the endovascular treatment of ruptured bifurcation aneurysms provides effective protection against rebleeding with a good safety profile. The angiographic occlusion rates at 1 year reported here are comparable to those already seen in previous multicenter studies which primarily included unruptured aneurysms.
引用
收藏
页码:650 / +
页数:6
相关论文