共 50 条
Enhanced S-Cone Syndrome: Elevated Cone Counts Confer Supernormal Visual Acuity in the S-Cone Pathway
被引:1
|作者:
Wang, Yiyi
[1
]
Wong, Jessica
[2
]
Duncan, Jacque L.
[2
]
Roorda, Austin
[1
]
Tuten, William S.
[1
,3
]
机构:
[1] Univ Calif Berkeley, Herbert Wertheim Sch Optometry & Vis Sci, Berkeley, CA USA
[2] Univ Calif San Francisco, Dept Ophthalmol, San Francisco, CA USA
[3] Univ Calif Berkeley, Herbert Wertheim Sch Optometry & Vis Sci, 412 Minor Addit, Berkeley, CA 94720 USA
关键词:
retinal degeneration;
visual acuity;
adaptive optics retinal imaging;
enhanced s-cone syndrome;
NUCLEAR RECEPTOR NR2E3;
RETINAL GANGLION-CELLS;
MOUSE MODEL;
PHOTORECEPTOR DIFFERENTIATION;
ROD PHOTORECEPTORS;
ADAPTIVE OPTICS;
RESOLUTION;
VISION;
MACAQUE;
SENSITIVITY;
D O I:
10.1167/iovs.64.10.17
中图分类号:
R77 [眼科学];
学科分类号:
100212 ;
摘要:
PURPOSE. To measure photoreceptor packing density and S-cone spatial resolution as a function of retinal eccentricity in patients with enhanced S-cone syndrome (ESCS) and to discuss the possible mechanisms supporting their supernormal S-cone acuity. METHODS. We used an adaptive optics scanning laser ophthalmoscope (AOSLO) to char-acterize photoreceptor packing. A custom non-AO display channel was used to measure L/M-and S-cone-mediated visual acuity during AOSLO imaging. Acuity measurements were obtained using a four-alternative, forced-choice, tumbling E paradigm along the temporal meridian between the fovea and 4 & DEG; eccentricity in five of six patients and in seven control subjects. L/M acuity was tested by presenting long-pass-filtered optotypes on a black background, excluding wavelengths to which S-cones are sensitive. S-cone isolation was achieved using a two-color, blue-on-yellow chromatic adaptation method that was validated on three control subjects. RESULTS. Inter-cone spacing measurements revealed a near-uniform cone density profile (ranging from 0.9-1.5 arcmin spacing) throughout the macula in ESCS. For comparison, normal cone density decreases by a factor of 14 from the fovea to 6 & DEG;. Cone spacing of ESCS subjects was higher than normal in the fovea and subnormal beyond 2 & DEG;. Compared to the control subjects (n = 7), S-cone-mediated acuities in patients with ESCS were normal near the fovea and became increasingly supernormal with retinal eccentricity. Beyond 2 & DEG;, S-cone acuities were superior to L/M-cone-mediated acuity in the ESCS cohort, a reversal of the trend observed in normal retinas. CONCLUSIONS. Higher than normal parafoveal cone densities (presumably dominated by S-cones) confer better than normal S-cone-mediated acuity in ESCS subjects.
引用
收藏
页数:13
相关论文