Failure Analysis of Low-Pressure Evaporator in Heat Recovery Steam Generator with 200 ton/h of Capacity

被引:0
|
作者
Purwanto, Tri Sigit [1 ]
Permana, Diki Ismail [1 ,2 ]
Nurbanasari, Meilinda [1 ]
Abdurrachim [3 ]
Sirodz, Muhammad Pramuda Nugraha [1 ]
机构
[1] Inst Teknol Nas Bandung, Fac Ind Engn, Mech Engn Dept, Bandung, Indonesia
[2] Hungarian Univ Agr & Life Sci, Doctoral Study Mech Engn, Szent Istvan Campus, Godollo, Hungary
[3] Univ Pasundan, Fac Engn, Dept Mech Engn, Bandung, Indonesia
关键词
Failure analysis; HRSG; Thermal stress; Evaporator; Material pipe; SUPERHEATER; BOILER; TUBES;
D O I
10.1007/s11668-023-01769-7
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
A steam-gas power plant (SGPP) combines a gas power plant (GPP) and a steam power plant by using the exhaust gas from the GPP to produce steam in the heat steam recovery generator (HRSG). The SGPP, which has a 200 ton/h HRSG capacity, experienced cracks, ruptures, and fatigue at the connection of the low-pressure evaporator pipe. Fatigue is a common failure mechanism in mechanical components due to thermal stress. However, the exact cause of the failure was unknown; therefore, a root cause analysis was conducted. Analysis included the thickness, metallography, chemical composition, tensile testing, thermography, defect testing, and hardness testing. The research showed thermal stresses were the cause of the low-pressure evaporator HRSG pipe failure. In addition, inspection results revealed a decrease in tensile strength, material hardness, and thermal expansion that exceeded the allowed limit.
引用
收藏
页码:2575 / 2587
页数:13
相关论文
共 50 条
  • [1] Failure Analysis of Low-Pressure Evaporator in Heat Recovery Steam Generator with 200 ton/h of Capacity
    Tri Sigit Purwanto
    Diki Ismail Permana
    Meilinda Nurbanasari
    Muhammad Pramuda Nugraha Abdurrachim
    Journal of Failure Analysis and Prevention, 2023, 23 : 2575 - 2587
  • [2] Failure analysis of a low-pressure stage steam turbine blade
    Rani, Pooja
    Agrawal, Atul K. K.
    NONDESTRUCTIVE TESTING AND EVALUATION, 2023, 38 (04) : 668 - 682
  • [3] A non-linear controller design for the evaporator of a heat recovery steam generator
    Tahami, F.
    Nademi, H.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART A-JOURNAL OF POWER AND ENERGY, 2009, 223 (A5) : 535 - 541
  • [4] HEAT-RECOVERY FROM LOW-PRESSURE STEAM BOILER FLUE-GASES
    KUNSTADT, H
    BUILDING SYSTEMS DESIGN, 1978, 75 (01): : 49 - 58
  • [5] A study of natural circulation in the evaporator of a horizontal-tube heat recovery steam generator
    Roslyakov P.V.
    Pleshanov K.A.
    Sterkhov K.V.
    Thermal Engineering, 2014, 61 (7) : 465 - 472
  • [6] Evaluation of Stress and Fatigue Life of a Tube Bundle and Header for the High-Pressure Evaporator of a Heat Recovery Steam Generator
    Lee, Boo Youn
    TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2018, 42 (12) : 1087 - 1099
  • [7] Mathematical modelling of single pressure heat recovery steam generator
    Plis, Marcin
    Rusinowski, Henryk
    2015 16TH INTERNATIONAL CARPATHIAN CONTROL CONFERENCE (ICCC), 2015, : 399 - 404
  • [8] Corrosion Failure Analysis of Condensate Pre-Heater in Heat Recovery Steam Generator
    Chae, Hobyung
    Kim, Woo Cheol
    Kim, Heesan
    Kim, Jung-Gu
    Kim, Kyung Min
    Lee, Soo Yeol
    CORROSION SCIENCE AND TECHNOLOGY-KOREA, 2021, 20 (02): : 69 - 76
  • [9] Investigation into Factors Causing Damage to Low-Pressure Loop Evaporating Tubes of Large-Capacity Heat-Recovery Steam Generators
    Pleshanov, K. A.
    Maslov, R. S.
    Pankov, V. S.
    Sterkhov, K. V.
    Khokhlov, D. A.
    THERMAL ENGINEERING, 2020, 67 (08) : 543 - 553
  • [10] Investigation into Factors Causing Damage to Low-Pressure Loop Evaporating Tubes of Large-Capacity Heat-Recovery Steam Generators
    K. A. Pleshanov
    R. S. Maslov
    V. S. Pankov
    K. V. Sterkhov
    D. A. Khokhlov
    Thermal Engineering, 2020, 67 : 543 - 553