M2ECG: Wearable Mechanocardiograms to Electrocardiogram Estimation Using Deep Learning

被引:3
|
作者
Tapotee, Malisha Islam [1 ]
Saha, Purnata [1 ]
Mahmud, Sakib [2 ]
Alqahtani, Abdulrahman [3 ,4 ]
Chowdhury, Muhammad E. H. [2 ]
机构
[1] Univ Dhaka, Dept Elect & Elect Engn, Dhaka 1000, Bangladesh
[2] Qatar Univ, Dept Elect Engn, Doha, Qatar
[3] Prince Sattam Bin Abdulaziz Univ, Coll Appl Med Sci, Dept Biomed Technol, Al Kharj 11942, Saudi Arabia
[4] Majmaah Univ, Coll Appl Med Sci, Dept Med Equipment Technol, Al Majmaah 11952, Saudi Arabia
关键词
Mechanocardiogram (MCG); electrocardiogram (ECG); seismocardiogram (SCG); gyrocardiogram (GCG); SA-UNet; 1D-segmentation; heart rate (HR); heart rate variability (HRV); HEART-RATE-VARIABILITY; ABSOLUTE ERROR MAE; SIGNAL; RMSE;
D O I
10.1109/ACCESS.2024.3353463
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Chest surface vibrations induced by cardiac activities can provide valuable insights into various heart conditions. Seismocardiogram (SCG) and Gyrocardiogram (GCG) signals, collectively referred to as Mechanocardiograms (MCG) and collected using a chest-mounted accelerometer and gyroscope, respectively, have the potential to serve as an effective alternative to Electrocardiograms (ECG) for continuous cardiac monitoring. In many cases, both modalities (MCG and ECG) can be used in tandem to monitor cardiac functions in both healthy subjects and Intensive Care Unit (ICU) patients. Direct acquisition of ECGs can be challenging in certain scenarios, such as with wearable devices, or due to issues with disconnections arising from loose contact surfaces or gel corrosion during long-term usage. ECG considered the gold standard for heart monitoring, is essential for a comprehensive assessment of cardiac parameters and patient health. MCGs have the potential to reliably estimate ECGs and can replace direct ECG acquisition procedures in such cases. In this study, we introduce M2ECG, a 1D-segmentation-based approach for translating ECG signals from the corresponding MCG signals acquired by an Inertial Measurement Unit (IMU) attached to the chest wall. Using the proposed SA-UNet, we achieved an average Pearson Correlation Coefficient (PCC) of 81.76% on a subject-independent test set. We also compared the estimated heart rates (HR) from the reconstructed ECGs to the ground truth ECGs to validate our model's performance. The overall HR correlation achieved on the subject-independent test set was around 94.167%. The highest correlation of the HR and HRV calculated from the translated and the ground truth ECGs were around 99.073% and 96.289%, respectively for the best test case. The strong correlation observed in cardiac parameters (HR, HRV) underscores the effectiveness of MCG, suggesting its potential use for continuous monitoring of cardiac patients.
引用
收藏
页码:12963 / 12975
页数:13
相关论文
共 50 条
  • [1] Detection of Abnormalities in Electrocardiogram (ECG) using Deep Learning
    Pestana, Joao
    Belo, David
    Gamboa, Hugo
    PROCEEDINGS OF THE 13TH INTERNATIONAL JOINT CONFERENCE ON BIOMEDICAL ENGINEERING SYSTEMS AND TECHNOLOGIES, VOL 4: BIOSIGNALS, 2020, : 236 - 243
  • [2] Electrocardiogram (ECG)-Based User Authentication Using Deep Learning Algorithms
    Agrawal, Vibhav
    Hazratifard, Mehdi
    Elmiligi, Haytham
    Gebali, Fayez
    DIAGNOSTICS, 2023, 13 (03)
  • [3] Using Deep Learning for Energy Expenditure Estimation with Wearable Sensors
    Zhu, Jindan
    Pande, Amit
    Mohapatra, Prasant
    Han, Jay J.
    2015 17TH INTERNATIONAL CONFERENCE ON E-HEALTH NETWORKING, APPLICATION & SERVICES (HEALTHCOM), 2015, : 501 - 506
  • [4] A deep learning framework for electrocardiogram (ECG) super resolution and arrhythmia classification
    Kaniraja C.P.
    M V.D.
    Mishra D.
    Res. Biomed. Eng., 1 (199-211): : 199 - 211
  • [5] ECG CLASSIFICATION USING HIGHER ORDER SPECTRAL ESTIMATION AND DEEP LEARNING TECHNIQUES
    Alquran, H.
    Alqudah, A. M.
    Abu-Qasmieh, I
    Al-Badarneh, A.
    Almashaqbeh, S.
    NEURAL NETWORK WORLD, 2019, 29 (04) : 207 - 219
  • [6] Entropy-Facilitated Machine Learning for Blood Pressure Estimation Using Electrocardiogram and Photoplethysmogram in a Wearable Device
    Ma, Kevin Sheng-Kai
    Hao, Hong
    Huang, Hung-Chun
    Tang, Yun-Hsiang
    2021 14TH INTERNATIONAL CONGRESS ON IMAGE AND SIGNAL PROCESSING, BIOMEDICAL ENGINEERING AND INFORMATICS (CISP-BMEI 2021), 2021,
  • [7] Fall Detection from Electrocardiogram (ECG) Signals and Classification by Deep Transfer Learning
    Butt, Fatima Sajid
    La Blunda, Luigi
    Wagner, Matthias F.
    Schaefer, Joerg
    Medina-Bulo, Inmaculada
    Gomez-Ullate, David
    INFORMATION, 2021, 12 (02) : 1 - 22
  • [8] Blood pressure estimation using electrocardiogram (ECG) and seismocardiogram (SCG) signals
    Han, Seung-Ju
    Lee, Sangmin
    BASIC & CLINICAL PHARMACOLOGY & TOXICOLOGY, 2021, 128 : 3 - 3
  • [9] Optimization of Deep Learning Models for Enhanced Respiratory Signal Estimation Using Wearable Sensors
    Kim, Jiseon
    Kim, Jooyong
    PROCESSES, 2025, 13 (03)
  • [10] A Continuous, Wearable, and Wireless Heart Monitor using Head Ballistocardiogram (BCG) and Head Electrocardiogram (ECG)
    Da He, David
    Winokur, Eric S.
    Sodini, Charles G.
    2011 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2011, : 4729 - 4732