Assessment of the Correlation between the Monitored Operating Parameters and Bearing Life in the Milling Head of a CNC Computer Numerical Control Machining Center

被引:1
|
作者
Baron, Petr [1 ]
Pivtorak, Oleksandr [1 ]
Ivan, Jan [1 ]
Kocisko, Marek [1 ]
机构
[1] Tech Univ Kosice, Fac Mfg Technol, Presov 08001, Slovakia
关键词
vibrodiagnostics; lubricant analysis; bearing microgeometry; bearing life; STEEL; MODEL;
D O I
10.3390/machines12030188
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The present paper describes a study conducted at the request of the operator of machining center equipment. The operator observed undesirable indicators in terms of increased backlash and vibration of the milling head and poor quality of the machined surfaces. Vibration measurements and vibrodiagnostics were carried out before disassembling the milling head in the idle state. The bearings, lubricant, and friction regime were analyzed in the next step. The vibrodiagnostic methods used included VEL, ACC, EN2, EN3, and EN4, with recommended limits conforming to STN ISO 10816-3. The vibration values obtained indicated a problem with the bearings, exceeding the limit values. After disassembly of the bearings, abrasive wear, corrosion, and improper lubricant conditions were detected. Lubricant analysis showed the presence of abrasive and corrosive particles, indicating an unsatisfactory friction regime. Determining the optimum lubricant temperature and the effect on friction torque constituted other aspects of the study. Inspection of the bearing microgeometry confirmed unsatisfactory roundness. Furthermore, the assembly of tapered roller bearings with axial preload was analyzed with a focus on bearing stiffness, accuracy, and life. The results showed that preload improves shaft guidance accuracy and load distribution, promoting reliable operation and extending bearing life.
引用
收藏
页数:22
相关论文
empty
未找到相关数据