Screening of subclinical functional hemoglobin and red blood cell abnormalities among blood donors of Fayoum University Hospital in Egypt: Are RET-He, and IRF useful screening tools?

被引:1
|
作者
Bakr, Salwa [1 ,5 ]
Yousief, Eman [1 ]
Ezzat, Eman Mahmoud [2 ]
Elsary, Asmaa Younis [3 ]
Elamir, Azza M. [4 ]
Gamal, Mona [1 ]
机构
[1] Fayoum Univ, Fac Med, Dept Clin Pathol Hematol, Faiyum, Egypt
[2] Fayoum Univ, Fac Med, Dept Internal Med, Faiyum, Egypt
[3] Fayoum Univ, Fac Med, Dept Publ Hlth & Community Med, Faiyum, Egypt
[4] Fayoum Univ, Fac Med, Dept Med Biochem & Mol Biol, Faiyum, Egypt
[5] Fayoum Univ, Fac Med, Dept Clin Pathol Hematol & Transfus Med, POB 63514, Al Fayyum, Egypt
关键词
Blood donor; Red cell screening; Neonatal transfusion; Transfusion-dependent; RET-He; IRF; IRON-DEFICIENCY ANEMIA; BETA-THALASSEMIA TRAIT; GLUCOSE-6-PHOSPHATE-DEHYDROGENASE DEFICIENCY; DIAGNOSIS; TRANSFUSION; PREVALENCE; STORAGE; DIFFERENTIATE; PARAMETERS; EQUIVALENT;
D O I
10.1016/j.transci.2023.103781
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: The effectiveness of red cell transfusion in a given blood unit that relied on both quantity and quality of donated cells undoubtedly affects prognostic outcomes.Objective: We aimed to determine the frequency of subclinical functional hemoglobin and red cell abnormalities in donated blood of Fayoum University Hospital in Egypt. Additionally, to assess the usefulness of reticulocyte mean hemoglobin content (RET-He) and immature reticulocyte fraction (IRF) as screening measures for such abnormalities.Material and methods: This cross-sectional study enrolled 200 volunteer blood donors who met the national standard criterion of blood donation. Complete blood count with reticulocyte parameters, serum ferritin, sickling test, G6PD assay, Mentzer index, and naked-eye single tube red cell osmotic fragility test were carried out.Results: Functional red cell abnormalities represented 44 % of this cohort. Out of them, 4.5 % had iron deficiency, 11 % had a positive sickling test, 19 % had G6PD deficiency, and 9.5 % had suspicious thalassemia. The sensitivity and specificity test for RET-He in selective identification of functional hemoglobin abnormalities in donated blood were 83.3 % and 61.2 %, respectively at a cutoff value of 26.9. Though there was no statistically significant effect of RET-He on the selective detection of G6PD deficiency, IRF had a statistically significant high level with a p-value of 0.04.Conclusion: Subclinical functional red cell abnormalities seem to be prevalent among blood donors. Reticulocyte/ erythrocyte indices could be useful screening tools for red cell abnormalities. Further studies are required for assessing the impact of transfusing such abnormalities to neonates and other critical recipients.
引用
收藏
页数:7
相关论文
共 7 条
  • [1] Molecular Screening for Malaria among Blood Donors in a WHO Claimed Region of Egypt, Fayoum Governorate
    Bakr, Salwa
    Edris, Sherif
    Fattah, Nashwa S. Abdel
    Ibrahim, Noha Mohamed
    El-Khadragy, Manal F.
    MEDITERRANEAN JOURNAL OF HEMATOLOGY AND INFECTIOUS DISEASES, 2017, 9
  • [2] Extended red blood cell phenotyping among regular donors in Fayoum, Egypt. Red Blood Cell Inventory Plan
    Abdelrazik, Abeer M.
    Abdelaziz, Hossam M.
    EGYPTIAN JOURNAL OF HAEMATOLOGY, 2023, 48 (01): : 9 - 12
  • [3] Reticulocyte Hemoglobin Equivalent (Ret-He) Combined with Red Blood Cell Distribution Width Has a Differentially Diagnostic Value for Thalassemias
    Lian, Yu
    Shi, Jun
    Nie, Neng
    Huang, Zhendong
    Shao, Yingqi
    Zhang, Jing
    Huang, Jinbo
    Li, Xingxin
    Ge, Meili
    Jin, Peng
    Wang, Min
    Zheng, Yizhou
    HEMOGLOBIN, 2019, 43 (4-5) : 229 - 235
  • [4] Prevalence of Red Blood Cell Antigen Phenotypes Among Omani Blood Donors; A Study at a University Hospital Blood Bank
    Al-Riyami, Arwa Z.
    Al-Marhoobi, Ali
    Al-Hosni, Saif
    Al-Mahrooqi, Sabah
    Al-Khabori, Murtadha
    TRANSFUSION, 2017, 57 : 153A - 154A
  • [5] Performances of TPHA, RPR and rapid immuno-chromatographic test in syphilis screening among blood donors at the university teaching hospital of Yaounde, Cameroon
    Tagny, C. T.
    NonoTagny, O.
    Balogog, P. Ngo
    Ndoumba, A.
    Mbanya, D.
    TRANSFUSION CLINIQUE ET BIOLOGIQUE, 2016, 23 (02) : 113 - 116
  • [6] COMPARISON OF RETICULOCYTE HEMOGLOBIN CONTENT (RET-HE), %HYPO HE AND % MICRO R IN SYSMEX XE-5000 VERSUS RED BLOOD CELL SIZE FACTOR (RSF), LOW HEMOGLOBIN DENSITY (LHD) AND MICROCYTIC ANAEMIA FACTOR (MAF) IN UNICEL DXH 800 IN DIAGNOSIS OF ANAEMIA
    Ambayya, Angeli
    Osman, Nadila Haryani
    Samsudin, Nik Rosnita Nik
    Ismail, Ilaina Hikmah
    Yong, Choong Chuan
    Khalid, Khadijah
    Meng, Chang Kian
    Yegappan, Subramanian
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2013, 35 : 40 - 40
  • [7] Comparison Among a New Non-Invasive Hemoglobin Measurement System, Capillary Blood Azide-Metahemoglobin Test and Red Blood Cell Count for Pre-Donation Screening
    Belardinelli, A.
    Benni, M.
    Tommasi, D.
    Zampino, D.
    Pagliaro, P.
    TRANSFUSION, 2011, 51 : 97A - 97A