Comparison of Serial and Parallel Connections of Membrane Lungs against Refractory Hypoxemia in a Mock Circuit

被引:0
|
作者
Omlor, Albert J. [1 ]
Caspari, Stefan [1 ]
Omlor, Leonie S. [2 ]
Jungmann, Anna M. [1 ]
Krawczyk, Marcin [3 ,4 ]
Schmoll, Nicole [1 ]
Mang, Sebastian [1 ]
Seiler, Frederik [1 ]
Muellenbach, Ralf M. [5 ]
Bals, Robert [1 ,6 ]
Lepper, Philipp M. [1 ]
机构
[1] Univ Hosp Saarland, Dept Internal Med Pneumol Allergol & Intens Care 5, D-66424 Homburg, Germany
[2] Univ Hosp Saarland, Dept Anaesthesiol & Crit Care, D-66424 Homburg, Germany
[3] Univ Hosp Saarland, Dept Internal Med 2, D-66424 Homburg, Germany
[4] Med Univ Warsaw, Ctr Preclin Res, Lab Metab Liver Dis, Dept Gen Transplant & Liver Surg, PL-02091 Warsaw, Poland
[5] Univ Southampton, Dept Anaesthesiol & Crit Care, Campus Kassel, D-34125 Kassel, Germany
[6] Helmholtz Ctr Infect Res HZI, Helmholtz Inst Pharmaceut Res Saarland HIPS, D-66123 Saarbrucken, Germany
关键词
ECMO; mock circuit; serial; parallel; refractory hypoxemia; oxygenator; membrane lung; OXYGENATION; ECMO;
D O I
10.3390/membranes13100809
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Extracorporeal membrane oxygenation (ECMO) is an important rescue therapy method for the treatment of severe hypoxic lung injury. In some cases, oxygen saturation and oxygen partial pressure in the arterial blood are low despite ECMO therapy. There are case reports in which patients with such instances of refractory hypoxemia received a second membrane lung, either in series or in parallel, to overcome the hypoxemia. It remains unclear whether the parallel or serial connection is more effective. Therefore, we used an improved version of our full-flow ECMO mock circuit to test this. The measurements were performed under conditions in which the membrane lungs were unable to completely oxygenate the blood. As a result, only the photometric pre- and post-oxygenator saturations, blood flow and hemoglobin concentration were required for the calculation of oxygen transfer rates. The results showed that for a pre-oxygenator saturation of 45% and a total blood flow of 10 L/min, the serial connection of two identical 5 L rated oxygenators is 17% more effective in terms of oxygen transfer than the parallel connection. Although the idea of using a second membrane lung if refractory hypoxia occurs is intriguing from a physiological point of view, due to the invasiveness of the solution, further investigations are needed before this should be used in a wider clinical setting.
引用
收藏
页数:13
相关论文
共 13 条
  • [1] Comparison of serial and parallel Connection of ECMO Oxygenators in the Mock Model
    Omlor, A.
    Caspari, S.
    Bals, R.
    Lepper, P.
    PNEUMOLOGIE, 2023, 77 : S106 - S106
  • [2] The serial connection of two extracorporeal membrane oxygenators for patient with refractory hypoxemia
    Kang, Dong Hoon
    Kim, Jong Woo
    Kim, Sung Hwan
    Moon, Seong Ho
    Yang, Jun Ho
    Jung, Jae Jun
    Cha, Ho Jeong
    Choi, Jun Young
    Lee, Chung Eun
    Heo, Won
    Lim, Sung Dae
    Byun, Joung Hun
    HEART & LUNG, 2021, 50 (06): : 853 - 856
  • [3] Parallel circuits for refractory hypoxemia on venovenous extracorporeal membrane oxygenation
    Malik, Adnan
    Shears, Larry L.
    Zubkus, Dmitriy
    Kaczorowski, David J.
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2017, 153 (03): : e49 - e51
  • [4] Parallel oxygenators in the same circuit for refractory hypoxemia on veno-venous extracorporeal membrane oxygenation. A 3-patient series
    Hurtado, Sebastian
    Sepulveda, Veronica
    Godoy, Cesar
    Bahamondes, Rodrigo
    Kattan, Eduardo
    Mendez, Magdalena
    Besa, Santiago
    PERFUSION-UK, 2024, 39 (08): : 1715 - 1721
  • [5] Extracorporeal membrane oxygenation circuits in parallel for refractory hypoxemia in patients with COVID-19
    Patel, Yatrik J.
    Gannon, Whitney D.
    Francois, Sean A.
    Stokes, John W.
    Tipograf, Yuliya
    Landsperger, Janna S.
    Semler, Matthew W.
    Casey, Jonathan D.
    Rice, Todd W.
    Bacchetta, Matthew
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2024, 167 (02): : 746 - +
  • [6] Extracorporeal Membrane Oxygenation Circuits in Parallel for Refractory Hypoxemia in COVID-19: A Case Series
    Patel, Yatrik J.
    Stokes, John W.
    Gannon, Whitney D.
    Francois, Sean A.
    Wu, Wei Kelly
    Rice, Todd W.
    Bacchetta, Matthew
    ASAIO JOURNAL, 2022, 68 (08) : 1002 - 1009
  • [7] Parallel Venovenous Extracorporeal Membrane Oxygenation Circuits for Refractory Hypoxemia in a Super-Super-Obese Patient
    Shoni, Melina
    Lazar, Sofiane
    Jackson, Andrea
    Tonetti, Mary Kate
    Horak, Jiri
    Gutsche, Jacob
    Augoustides, John G.
    Marchant, Bryan E.
    Fernando, Rohesh J.
    Jelly, Christina Anne
    Gallo, Paul D.
    Mazzeffi, Michael A.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2023, 37 (07) : 1304 - 1314
  • [8] The utility of parallel venovenous extracorporeal membrane oxygenation circuits for refractory hypoxemia in severely burned patients: A case report
    Kwon, Oh Jin
    Rojo, Manuel
    Dobaria, Vishal
    Tedesco, John
    Schwartz, Jeffrey P.
    JTCVS TECHNIQUES, 2022, 15 : 126 - 129
  • [9] Comparison of Circular and Parallel-Plated Membrane Lungs for Extracorporeal Carbon Dioxide Elimination
    Schwaerzel, Leonie S.
    Jungmann, Anna M.
    Schmoll, Nicole
    Caspari, Stefan
    Seiler, Frederik
    Muellenbach, Ralf M.
    Bewarder, Moritz
    Quoc Thai Dinh
    Bals, Robert
    Lepper, Philipp M.
    Omlor, Albert J.
    MEMBRANES, 2021, 11 (06)
  • [10] Parallel veno-venous and veno-arterial extracorporeal membrane circuits for coexisting refractory hypoxemia and cardiovascular failure: a case report
    Jose R. Navas-Blanco
    Sofia A. Lifgren
    Roman Dudaryk
    Jeffrey Scott
    Matthias Loebe
    Ali Ghodsizad
    BMC Anesthesiology, 21