Heat losses in a trapezoidal cavity receiver of a linear Fresnel collector: A CFD approach

被引:6
|
作者
Alcalde-Morales, Sergio [1 ,2 ]
Valenzuela, Loreto [1 ]
Serrano-Aguilera, J. J. [2 ]
机构
[1] CIEMAT Plataforma Solar Almeria, Crta Senes Km 4-5, Tabernas 04200, Almeria, Spain
[2] Univ Malaga, Escuela Ingn Ind, Campus Teatinos S-N, Malaga 29071, Spain
关键词
Solar thermal energy; Linear Fresnel reflector; Cavity receiver; Computational fluid dynamics; Heat transfer; Heat losses; NUMERICAL-ANALYSIS; REFLECTOR; SIMULATION; ABSORBER; MODEL;
D O I
10.1016/j.heliyon.2023.e18692
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
This paper presents a thermal study of a cavity receiver designed for a Fresnel-type linear solar collector (LFC). The study utilizes a two-dimensional computational fluid dynamics (CFD) model implemented in ANSYS Fluent. The thermal behavior of air inside the cavity for a Fresnel collector is extensively examined. The receiver consists of a trapezoidal cavity with a set of six parallel absorber tubes, through which a thermal fluid circulates. The cavity has aluminum reflectors on the inner walls and glass window closing the aperture facing the primary reflectors of the solar collector. The two-dimensional numerical model represents a cross-section of the receiver, and aims to provide numerical results that allow to provide algebraic correlations for predicting heat losses in the receiver from the wall temperature of each of the six individual absorber tubes that compose it. The developed model is transient, utilizing the k-& epsilon; turbulent model. In addition, the study is completed with an analysis of the behavior of the air surrounding and inside the cavity, to evaluate its thermal performance. For this purpose, the velocity and temperature contours obtained with the two-dimensional model are discussed. Correlations are obtained to know the heat flux between the tubes and the heat loss through the window for any combination of temperatures for each pair of tubes, which has not been yet studied in the literature. The study reveals that radiative losses contribute to 81% of the total heat losses, with the outer tubes temperature being the main responsible for these losses. Furthermore, a dimensionless analysis examines the relationship between the Nusselt and Rayleigh numbers in comparison to reference problems based on canonical geometries dominated by buoyancy-driven flows. The performance is found to be similar to that of a downward hot flat plate.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Optical and thermal investigation of a linear Fresnel collector with trapezoidal cavity receiver
    Tsekouras, P.
    Tzivanidis, C.
    Antonopoulos, K.
    APPLIED THERMAL ENGINEERING, 2018, 135 : 379 - 388
  • [2] Numerical simulation of a trapezoidal cavity receiver for a linear Fresnel solar collector concentrator
    Facao, Jorge
    Oliveira, Armando C.
    RENEWABLE ENERGY, 2011, 36 (01) : 90 - 96
  • [3] Parametric investigation of thermal characteristic in trapezoidal cavity receiver for a linear Fresnel solar collector concentrator
    Dabiri, Soroush
    Khodabandeh, Erfan
    Poorfar, Alireza Khoeini
    Mashayekhi, Ramin
    Toghraie, Davood
    Zade, Seyed Ali Abadian
    ENERGY, 2018, 153 : 17 - 26
  • [4] Estimation of convective and radiative heat losses from an inverted trapezoidal cavity receiver of solar linear Fresnel reflector system
    Reddy, K. S.
    Kumar, K. Ravi
    INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2014, 80 : 48 - 57
  • [5] Analysis of heat losses from a trapezoidal cavity used for Linear Fresnel Reflector system
    Sahoo, Sudhansu S.
    Singh, Suneet
    Banerjee, Rangan
    SOLAR ENERGY, 2012, 86 (05) : 1313 - 1322
  • [6] Linear Fresnel collector receiver: heat loss and temperatures
    Heimsath, A.
    Cuevas, F.
    Hofer, A.
    Nitz, P.
    Platzer, W. J.
    PROCEEDINGS OF THE SOLARPACES 2013 INTERNATIONAL CONFERENCE, 2014, 49 : 386 - 397
  • [7] Heat transfer model for the trapezoidal cavity receiver of linear Fresnel reflector-type collectors
    Sanchez-Mora, Heriberto
    Escobedo-Izquierdo, M. Azucena
    Jaramillo-Mora, Alejandro
    Pericas, Raimon
    Quezada-Garcia, Sergio
    SOLAR ENERGY, 2025, 286
  • [8] Parametric Study on the Thermal Performance of a Trapezoidal Cavity Absorber for a Linear Fresnel Solar Collector
    Rabhi, Louiza
    Khmou, Ahmed
    Boutammachte, Noureddine
    Barek, Abdelaali Ait M.
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2019, 9 (02): : 830 - 839
  • [9] Performance investigation on a linear Fresnel lens solar collector using cavity receiver
    Lin, M.
    Sumathy, K.
    Dai, Y. J.
    Zhao, X. K.
    SOLAR ENERGY, 2014, 107 : 50 - 62
  • [10] Effect of Linear Fresnel Concentrators field key parameters on reflectors configuration, Trapezoidal Cavity Receiver dimension, and heat loss
    Roostaee, Amin
    Ameri, Mehran
    RENEWABLE ENERGY, 2019, 134 : 1447 - 1464