Single-Isocenter Linac-Based Radiosurgery for Brain Metastases with Coplanar Arcs: A Dosimetric and Clinical Analysis

被引:3
|
作者
Faccenda, Valeria [1 ]
Panizza, Denis [1 ,2 ]
Pisoni, Valerio [3 ]
Trivellato, Sara [1 ]
Daniotti, Martina Camilla [1 ]
Bianchi, Sofia Paola [2 ]
De Ponti, Elena [1 ,2 ]
Arcangeli, Stefano [2 ,3 ]
机构
[1] Fdn IRCCS San Gerardo Tintori, Med Phys Dept, I-20900 Monza, Italy
[2] Univ Milano Bicocca, Sch Med & Surg, I-20126 Milan, Italy
[3] Fdn IRCCS San Gerardo Tintori, Radiat Oncol Dept, I-20900 Monza, Italy
关键词
brain metastases; radiosurgery; stereotactic radiotherapy; linac; volumetric arc therapy; BEAM COMPUTED-TOMOGRAPHY; STEREOTACTIC RADIOSURGERY; RADIATION-THERAPY; SURGICAL RESECTION; ACCURACY; RADIOTHERAPY; FRAMELESS; QUALITY; VOLUME; PREDICTOR;
D O I
10.3390/cancers15184496
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The efficacy of linac-based SRS/fSRS treatments using the single-isocenter coplanar FFF-VMAT technique for both single and multiple BM was investigated. Seventy patients (129 BM) treated with 15-21 Gy in 1 (n = 59) or 27 Gy in 3 (n = 11) fractions were analyzed. For each fraction, plans involving the intra-fractional errors measured by post-treatment CBCT were recalculated. The relationships of BM size, distance-to-isocenter, and barycenter shift with the difference in target coverage were evaluated. Clinical outcomes were assessed using logistic regression and Kaplan-Meier analysis. The median delivery time was 3.78 min (range, 1.83-9.25). The median post-treatment 3D error was 0.5 mm (range, 0.1-2.7) and the maximum rotational error was 0.3 degrees (range, 0.0-1.3). In single BM patients, the GTV D95% was never reduced by >5%, whereas PTV D95% reductions >1% occurred in only 11 cases (29%). In multiple BM patients, dose deficits >5% and >1% occurred in 2 GTV (2%) and 34 PTV (37%), respectively. The differences in target coverage showed a moderate-to-strong correlation only with barycenter shift. Local failure of at least one treated BM occurred in 13 (21%) patients and the 1-year and 2-year local control rates for all lesions were 94% and 90%, respectively. The implemented workflow ensured that the degradation of target and brain dose metrics in delivered treatments was negligible. Along with encouraging clinical outcomes, these findings warrant a reduction in the PTV margins at our institution.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Dosimetric and Clinical Prognostic Factors in Single-Isocenter Linac-Based Stereotactic Radiotherapy for Brain Metastases
    Faccenda, Valeria
    Colciago, Riccardo Ray
    Bianchi, Sofia Paola
    De Ponti, Elena
    Panizza, Denis
    Arcangeli, Stefano
    CANCERS, 2024, 16 (18)
  • [2] Cost-effectiveness of Linac-based single-isocenter non-coplanar technique (HyperArcTM) for brain metastases radiosurgery
    Filippo Alongi
    Alba Fiorentino
    Ruggero Ruggieri
    Francesco Ricchetti
    Patrick Kupelian
    Clinical & Experimental Metastasis, 2018, 35 : 601 - 603
  • [3] Cost-effectiveness of Linac-based single-isocenter non-coplanar technique (HyperArcTM) for brain metastases radiosurgery
    Alongi, Filippo
    Fiorentino, Alba
    Ruggieri, Ruggero
    Ricchetti, Francesco
    Kupelian, Patrick
    CLINICAL & EXPERIMENTAL METASTASIS, 2018, 35 (07) : 601 - 603
  • [4] Optimization of treatment isocenter location in single-isocenter LINAC-based stereotactic radiosurgery for management of multiple brain metastases
    Cui, Taoran
    Zhou, Yongkang
    Yue, Ning J.
    Vergalasova, Irina
    Zhang, Yin
    Zhu, Jiahua
    Nie, Ke
    MEDICAL PHYSICS, 2021, 48 (12) : 7632 - 7640
  • [5] Predictive factors for clinical outcomes after single-isocenter linac-based SRS for brain metastases
    Faccenda, Valeria
    Panizza, Denis
    Bianchi, Sofia Paola
    De Ponti, Elena
    Arcangeli, Stefano
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S797 - S798
  • [6] Impact of setup errors on the robustness of linac-based single-isocenter coplanar and non-coplanar VMAT plans for multiple brain metastases
    Sun, Xiaohuan
    Guan, Fada
    Yun, Qinghui
    Jennings, Matthew
    Biggs, Simon
    Wang, Zhongfei
    Wang, Wei
    Zhang, Te
    Shi, Mei
    Zhao, Lina
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (07):
  • [7] Radiosurgery of multiple brain metastases with single-isocenter dynamic conformal arcs (SIDCA)
    Huang, Yimei
    Chin, Karen
    Robbins, Jared R.
    Kim, Jinkoo
    Li, Haisen
    Amro, Hanan
    Chetty, Indrin J.
    Gordon, James
    Ryu, Samuel
    RADIOTHERAPY AND ONCOLOGY, 2014, 112 (01) : 128 - 132
  • [8] Dosimetric impact of setup errors in single-isocenter VMAT radiosurgery for brain metastases
    Panizza, D.
    Faccenda, V.
    Trivellato, S.
    Caricato, P.
    Pisoni, V.
    Lucchini, R.
    De Ponti, E.
    Arcangeli, S.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S253 - S253
  • [9] Dosimetric Impact of Setup Errors in Single-Isocenter VMAT Radiosurgery for Brain Metastases
    Faccenda, V.
    Panizza, D.
    Trivellato, S.
    Daniotti, M. C.
    Pisoni, V.
    Lucchini, R.
    Arcangeli, S.
    De Ponti, E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E102 - E103
  • [10] Linac-based radiosurgery for multiple brain metastases: Comparison between two mono-isocenter techniques with multiple non-coplanar arcs
    Ruggieri, Ruggero
    Naccarato, Stefania
    Mazzola, Rosario
    Ricchetti, Francesco
    Corradini, Stefanie
    Fiorentino, Alba
    Alongi, Filippo
    RADIOTHERAPY AND ONCOLOGY, 2019, 132 : 70 - 78