Dose-response dependencies of Turnbull blue, modified Fricke, VIPET, and Presage® gel dosimeters in high-dose-rate radiation fields

被引:2
|
作者
Prusova, H. [1 ]
Dudas, D. [1 ,2 ]
Spevacek, V. [1 ]
Prusa, P. [1 ]
机构
[1] Czech Tech Univ, Fac Nucl Sci & Phys Engn, Dept Dosimetry & Applicat Ionizing Radiat, Brehova 7, Prague 11519 1, Czech Republic
[2] UJP PRAHA As, Kaminkou 1345, Prague 15600, Czech Republic
关键词
Gel dosimetry; 3D dosimetry; High dose rate; 60Co irradiation; POLYMER GEL; QUALITY-ASSURANCE; RADIOCHROMIC GEL; VERIFICATION; STABILITY; TOOL;
D O I
10.1016/j.radmeas.2023.106910
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Dose-response dependencies of the radiochromic Turnbull blue (TB), modified Fricke gel (FXO), polymer gel VIPET, and solid-state Presage (R) dosimeters were investigated, in high-dose-rate radiation fields, using spec-trophotometry. A sealed radionuclide source (60Co) with a dose rate up to 9 Gy s-1 was used for irradiation. Standard liquid Fricke solution was used as a reference dosimeter. It was found that the properties of different types of gel dosimeters are affected by the dose rate. The results were compared with the predictions derived from the physical-chemical irradiation response principles. Considerable dose-rate dependencies were observed for all investigated 3D dosimeters. Dose responses of TB, VIPET, and FXO were decreased by 30-40% while the Presage (R) response were decreased by approximately 20% for dose rates from 7.2 x 10-3 to 9.01 Gy s-1. Pre-sented results could have practical impact on some clinical applications, and therefore proper corrections might be needed.
引用
收藏
页数:7
相关论文
共 8 条
  • [1] A Verification of High-Dose-Rate Brachytherapy Dose Distributions for Prostate Cancer with a VIPET Polymer Gel Dosimeter
    Eguchi, K.
    Watanabe, Y.
    Mizukami, S.
    Maeyama, T.
    Hayashi, S.
    Gomi, T.
    MEDICAL PHYSICS, 2018, 45 (06) : E238 - E238
  • [2] Evaluating Local Control and Dose-Response Correlation after High-dose-Rate Interstitial Gynecologic Brachytherapy
    Thibault, I.
    Lavallee, M.
    Laflamme, N.
    Vigneault, E.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (03): : S412 - S412
  • [3] Clinical application of the Fricke-glucomannan gel dosimeter for high-dose-rate 192Ir brachytherapy
    Noda, S.
    Suzuki, Y.
    Hoshino, Y.
    Furukawa, S.
    Katoh, H.
    Kurotaki, K.
    Nakano, T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (14): : 3985 - 3993
  • [4] Pathologic evidence of dose-response and dose-volume relationships for prostate cancer treated with combined external beam radiotherapy and high-dose-rate brachytherapy
    Kestin, LL
    Goldstein, NS
    Vicini, FA
    Mitchell, C
    Gustafson, GS
    Stromberg, JS
    Chen, PY
    Martinez, AA
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2002, 54 (01): : 107 - 118
  • [5] Clinical application of the Fricke-glucomannan gel 3D dosimeter for a high-dose-rate 192Ir brachytherapy
    Noda, S.
    Suzuki, Y.
    Hoshino, Y.
    Furukawa, S.
    Kurotaki, K.
    Nakano, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2006, 66 (03): : S592 - S593
  • [6] Rectal Toxicity in Cervical Cancer After Intensity Modified Radiation Therapy and High-Dose-Rate Brachytherapy
    Gestaut, M. M.
    Jhavar, S. G.
    Vyas, S.
    Arora, D.
    Olek, D.
    Hasan, S.
    Axelrud, G.
    Deb, N.
    Thawani, N.
    Mutyala, S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2015, 93 (03): : E261 - E261
  • [7] Low Dose Rate X-Ray Radiation Fields Implementation for Study of Energy Response of the Dosimeters Based on Scintillation Detectors
    Novichenko, A. V.
    Lukashevich, R. V.
    Senkovsky, K. G.
    DEVICES AND METHODS OF MEASUREMENTS, 2019, 10 (02): : 128 - 137
  • [8] High-dose-rate stereotactic body radiation therapy for postradiation therapy locally recurrent prostatic carcinoma: Preliminary prostate-specific antigen response, disease-free survival, and toxicity assessment
    Fuller, Donald B.
    Wurzer, James
    Shirazi, Reza
    Bridge, Stephen S.
    Law, Jonathan
    Mardirossian, George
    PRACTICAL RADIATION ONCOLOGY, 2015, 5 (06) : E615 - E623