Objective detection of visual field defects with multifrequency VEPs

被引:0
|
作者
Crux, Katja [1 ]
Huchzermeyer, Cord [1 ]
Kremers, Jan [1 ]
Horn, Folkert K. [1 ,2 ]
机构
[1] Univ Hosp Erlangen, Dept Ophthalmol, Schwabachanlage 6, D-91054 Erlangen, Germany
[2] Friedrich Alexander Univ Erlangen Nurnberg, Univ Eye Hosp, Dept Ophthalmol, Schwabachanlage 6, D-91054 Erlangen, Germany
关键词
Steady state; Quadrant multifrequency VEP; Pattern reversal; Objective visual field test; Signal-to-noise ratio; STEADY-STATE; EVOKED POTENTIALS; MULTIFOCAL VEP; OPTIC NEURITIS; PERIMETRY; RESPONSES; GLAUCOMA; SYSTEM; DAMAGE;
D O I
10.1007/s10633-023-09949-4
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To correlate multifrequency pattern reversal VEPs in quadrants (QmfrVEPs) with perimetric field losses for objective detection of visual field losses. Methods QmfrVEP measurements were performed using four LED-based checkerboard stimulators to stimulate the four quadrants of the visual field. QmfrVEPs were measured monocularly in 5 normal subjects and in 5 glaucoma patients who showed losses in conventional Octopus perimetry. The pattern reversal frequency varied slightly between the stimulators: (11.92, 12.00, 12.08 and 12.16 reversals/sec). The responses to the different stimuli were identified by discrete Fourier analysis. VEPs were recorded using different electrode configurations, and the recording with the highest signal-to-noise ratio (SNR) was used for further analysis. Results QmfrVEP responses from the different quadrants can be reliably measured and separated using the 0.08 reversals/sec interstimulus reversal frequency differences. The signal-to-noise ratio in the four quadrants was significantly correlated with the equivalent visual field losses obtained with perimetry (Spearman rank correlation: P < 0.001). In the five glaucoma patients, the SNR was reduced in 15 out of the 16 quadrants with a perimetric defect, in comparison to the results in quadrants of healthy subjects. This confirms the sensitivity of the procedure. Conclusion QmfrVEP responses can be measured reliably. This pilot study suggests that high SNR values exclude visual field defects and that focal defects can be identified in glaucoma patients.
引用
收藏
页码:15 / 24
页数:10
相关论文
共 50 条
  • [1] Objective detection of visual field defects with multifrequency VEPs
    Katja Crux
    Cord Huchzermeyer
    Jan Kremers
    Folkert K. Horn
    Documenta Ophthalmologica, 2024, 148 : 15 - 24
  • [2] Mapping of glaucomatous visual field defects by multifocal VEPs
    Hasegawa, S
    Abe, H
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2001, 42 (13) : 3341 - 3348
  • [3] The detection of small simulated field defects using multifocal VEPs
    Chan, HL
    Tam, WK
    Chen, CL
    Ng, NC
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2003, 23 (03) : 205 - 212
  • [4] A child with epilepsy in whom multifocal VEPs facilitated the objective measurement of the visual field
    Yukawa, E
    Kim, YJ
    Kawasaki, K
    Taketani, F
    Hara, Y
    EPILEPSIA, 2005, 46 (04) : 577 - 579
  • [5] Multifocal topographic visual evoked potential: Improving objective detection of local visual field defects
    Klistorner, AI
    Graham, SL
    Grigg, JR
    Billson, FA
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1998, 39 (06) : 937 - 950
  • [6] Objective detection of hemifield and quadrantic field defects by visual evoked cortical potentials
    Bradnam, MS
    Montgomery, DMI
    Evans, AL
    Keating, D
    McClure, EA
    Damato, BE
    McFadzean, R
    BRITISH JOURNAL OF OPHTHALMOLOGY, 1996, 80 (04) : 297 - 303
  • [7] The detection of small relative simulated field defects using multifocal VEPs
    Chan, HL
    Chu, HW
    Ng, YF
    Tam, WK
    Young, SM
    Lam, CH
    Cheung, AL
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2005, 25 (03) : 224 - 232
  • [8] Objective assessment of visual field defects by multifocal ERG
    Kretschmann, U
    Gendo, K
    Wilhelm, H
    Schiefer, U
    Hettesheimer, H
    Zrenner, E
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1998, 212 (01) : 40 - 49
  • [9] The role of hemifield sector analysis in multifocal visual evoked potential objective perimetry in the early detection of glaucomatous visual field defects
    Mousa, Mohammad F.
    Cubbidge, Robert P.
    Al-Mansouri, Fatima
    Bener, Abdulbari
    CLINICAL OPHTHALMOLOGY, 2013, 7 : 843 - 857
  • [10] Automated objective characterization of visual field defects in 3D
    Fink, W
    Castano, R
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2002, 43 : U45 - U45