Exploring Alternative Methods to Reduce Milk Flow Rate From Infant Bottle Systems: Bottle Angle, Milk Volume, and Bottle Ventilation

被引:1
|
作者
McGrattan, Katlyn Elizabeth [1 ,2 ]
Jansen, Gregory Paul [1 ]
Barrera, Jennifer Meraz [1 ]
Beckstrand, Michael [3 ]
机构
[1] Univ Minnesota Twin Cities, Dept Speech Language & Hearing Sci, Minneapolis, MN 55455 USA
[2] Masonic Childrens Hosp, Dept Rehabil, Minneapolis, MN 55454 USA
[3] Univ Minnesota Twin Cities, Coll Liberal Arts, Minneapolis, MN USA
关键词
PRETERM INFANTS; PATTERNS; NIPPLES; SUCKING;
D O I
10.1044/2023_AJSLP-23-00109
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Purpose: Modifying milk flow rate is a common pediatric dysphagia treatment. Though past investigations have demonstrated how this can be achieved using bottle nipples, little is known about the impact of other bottle modifications. The objective of this investigation is to demonstrate how bottle vent, bottle position, and volume of milk alter bottle pressures and milk flow. Method: A Dr. Brown's bottle filled with formula was secured to a retort stand and inverted to allow milk to free flow from a Level 1 nipple. Milk flow rate and bottle pressures were calculated under three conditions: (a) with and without a vent in place; (b) with varying volumes of milk (1-4 oz); and (c) in horizontal, semi-inverted, and completely inverted positions. Differences between flow rates under the conditions were tested using repeated-measures analysis of variance. Results: Upon inversion, milk dripped from both vented and unvented bottles. Dripping continued throughout the 20-min testing period in the vented bottle; however, as air pressure and hydrostatic pressure declined (p < .01) in the unvented bottle, milk flow slowed and eventually ceased (p < .001). As angle of bottle inversion increased, hydrostatic pressure and milk flow rate had corresponding increases as well (p < .001). Hydrostatic pressure increased an average of 1.4 +/- 0.12 mm Hg per additional ounce of formula that was added to the bottle, with corresponding increases in milk flow rate observed (p < .001). Conclusions: Milk flow rate can be altered by feeding conditions outside of bottle nipples alone. Future work examining the clinical significance of these modifications is warranted to determine optimal interventions.
引用
收藏
页码:2245 / 2253
页数:9
相关论文
共 29 条
  • [1] Milk Flow Rates from Bottle Nipples
    Pados, Britt
    Estrem, Hayley
    Nix, William B.
    Park, Jinhee
    Thoyre, Suzanne
    NURSING RESEARCH, 2013, 62 (02) : E1 - E2
  • [2] Why Feed Breast Milk From a Bottle?
    Whitaker, Robert C.
    Wright, Jeffrey A.
    ARCHIVES OF PEDIATRICS & ADOLESCENT MEDICINE, 2012, 166 (05): : 483 - 484
  • [3] Relationship of Feeding Human Milk by Breast Versus Bottle with Infant Growth
    Wilson, Kelsey
    Lovelady, Cheryl
    FASEB JOURNAL, 2015, 29
  • [4] MILK FLOW RATES from bottle nipples used after hospital discharge
    Pados, Britt Frisk
    Park, Jinhee
    Thoyre, Suzanne M.
    Estrem, Hayley
    Nix, W. Brant
    MCN-THE AMERICAN JOURNAL OF MATERNAL-CHILD NURSING, 2016, 41 (04) : 237 - 243
  • [5] Comparison of human milk bottle with infant/toddler test weights in the community setting
    Esquerra-Zwiers, Anita L.
    Heter, Madeline
    Perecki, Anastasia
    Jackson, Olivia
    Jongekryg, D. Addam
    Yurk, Brian
    BMC NUTRITION, 2024, 10 (01)
  • [6] Know the Flow Milk Flow Rates From Bottle Nipples Used in the Hospital and After Discharge
    Pados, Britt Frisk
    Park, Jinhee
    Dodrill, Pamela
    ADVANCES IN NEONATAL CARE, 2019, 19 (01) : 32 - 41
  • [7] Milk Flow Rates From Bottle Nipples Used for Feeding Infants Who Are Hospitalized
    Pados, Britt F.
    Park, Jinhee
    Thoyre, Suzanne M.
    Estrem, Hayley
    Nix, W. Brant
    AMERICAN JOURNAL OF SPEECH-LANGUAGE PATHOLOGY, 2015, 24 (04) : 671 - 679
  • [8] Decreasing retinol and a-tocopherol concentrations in human milk and infant formula using varied bottle systems
    Francis, Jimi
    Rogers, Kristy
    Dickton, Darby
    Twedt, Roxanna
    Pardini, Ron
    MATERNAL AND CHILD NUTRITION, 2012, 8 (02): : 215 - 224
  • [9] BREATHING PATTERNS OF PRETERM INFANTS DURING BOTTLE FEEDING - ROLE OF MILK FLOW
    MATHEW, OP
    JOURNAL OF PEDIATRICS, 1991, 119 (06): : 960 - 965
  • [10] A Novel Improvised Laryngectomy Button Designed From A Milk Bottle Teat
    Chee, Yen Min Madeline
    Roche, Elizabeth
    Tay, Ci An Gerald
    OTO OPEN, 2023, 7 (04)