A study of differential potentiometric stripping analysis for lead and cadmium with Nafion coated carbon fibre electrode

被引:0
|
作者
DONG
HE
WANG
机构
基金
中国国家自然科学基金;
关键词
A study of differential potentiometric stripping analysis for lead and cadmium with Nafion coated carbon fibre electrode;
D O I
暂无
中图分类号
学科分类号
摘要
The differential potentiometric stripping analysis (DPSA) with Nafion coated carbon fibreelectrode has been studied, and a method to determine lead and cadmium in urine directly has beenattempted. The effect of various experimental parameters on the DPSA response is discussed.The experimental conditions include 0.2M sodium perchlorate, deposition potential of-1.0 or -1.1 Vand using 20 ppm mercuric ion as oxidizing agent. The response of the signal is in linear relationwith the concentrations of lead and cadmium respectively up to 0.5 ppm. The electrode coated withNafion film alleviates the interference from organics in urine samples.
引用
收藏
页码:507 / 511
页数:5
相关论文
共 50 条
  • [1] Stripping potentiometry of lead, cadmium and copper at a nafion coated glassy carbon electrode with encapsulated mercury acetate
    Macca, C
    Bradshaw, M
    Merkoci, A
    Scollary, G
    ANALYTICAL LETTERS, 1997, 30 (06) : 1223 - 1234
  • [2] Stripping Potentiometry of Lead, Cadmium and Copper at a Nafion Coated Glassy Carbon Electrode with Encapsulated Mercury Acetate
    Macca, C.
    Bradshaw, M.
    Merkoci, A.
    Scollary, G.
    Analytical Letters, 30 (06):
  • [3] Potentiometric Stripping Analysis of Cadmium and Lead with Constant Inverse Current in the Analytical Step Using an Open Tubular Mercury-Coated Glassy Carbon Electrode
    Suturovic, Zvonimir J.
    Kravic, Snezana Z.
    Stojanovic, Zorica S.
    Durovic, Ana D.
    Brezo-Borjan, Tanja Z.
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2019, 2019
  • [4] Nafion-mercury coated film electrode for the adsorptive stripping voltammetric determination of lead and cadmium in the presence of pyrogallol red
    Nagles, Edgar
    Arancibia, Veronica
    Rojas, Carlos
    Segura, Rodrigo
    TALANTA, 2012, 99 : 119 - 124
  • [5] Determination of cadmium, lead and copper in wine by potentiometric stripping analysis
    Ostapczuk, P
    Eschnauer, HR
    Scollary, GR
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1997, 358 (06): : 723 - 727
  • [6] Determination of cadmium, lead and copper in wine by potentiometric stripping analysis
    P. Ostapczuk
    H. R. Eschnauer
    G. R. Scollary
    Fresenius' Journal of Analytical Chemistry, 1997, 358 : 723 - 727
  • [7] DETERMINATION OF LEAD AND CADMIUM IN BIOLOGICAL SAMPLES BY POTENTIOMETRIC STRIPPING ANALYSIS
    BINOTHMAN, MR
    HILL, JO
    MAGEE, RJ
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1987, 326 (04): : 350 - 353
  • [8] Determination of Metoclopramide with Differential PulseAnodic Stripping Voltammetry by Nafion-coated electrode
    朴元哲
    王清珊
    李贤英
    崔胜云
    朴承允
    池莲花
    延边大学学报(自然科学版), 1995, (04) : 38 - 42
  • [9] ANALYSIS OF LEAD AND CADMIUM IN DECIDUOUS TEETH BY MEANS OF POTENTIOMETRIC STRIPPING ANALYSIS
    NOREN, JG
    HULTHE, P
    GILLBERG, C
    SWEDISH DENTAL JOURNAL, 1987, 11 (1-2) : 45 - 52
  • [10] Simultaneous Determination of Lead and Cadmium by Stripping Voltammetry Using in-situ Mercury Film Glassy Carbon Electrode Coated with Nafion-Macrocyclic Ester
    Lara, Jesid
    Torres, Juan F.
    Beltran, Olimpo Garcia
    Nagles, Edgar
    Hurtado, John
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (08): : 6920 - 6929