Evaluation and improvement of wastewater treatment plant performance using BioWin

被引:0
|
作者
OLEYIBLO Oloche James [1 ]
操家顺 [1 ,2 ]
冯骞 [1 ]
王淦 [3 ]
薛朝霞 [1 ]
方芳 [1 ]
机构
[1] College of Environment,Hohai University
[2] National Engineering Research Center of Water Resource Efficient Utilization and Engineering Safety,Hohai University
[3] Anhui Guozhen Environmental Protection Sci. and Tech. Co. Ltd.
关键词
activated sludge; aeration tank; equalization tank; secondary clarifier; wet weather;
D O I
暂无
中图分类号
X703 [废水的处理与利用];
学科分类号
083002 ;
摘要
In this study,the activated sludge model implemented in the BioWin software was validated against full-scale wastewater treatment plant data. Only two stoichiometric parameters(Y p /acetic and the heterotrophic yield(Y H)) required calibration. The value 0.42 was used for Yp /acetic in this study,while the default value of the BioWin software is 0.49,making it comparable with the default values of the corresponding parameter(yield of phosphorus release to substrate uptake(YPO4)) used in ASM2,ASM2 d,and ASM3 P,respectively. Three scenarios were evaluated to improve the performance of the wastewater treatment plant,the possibility of wasting sludge from either the aeration tank or the secondary clarifier,the construction of a new oxidation ditch,and the construction of an equalization tank. The results suggest that construction of a new oxidation ditch or an equalization tank for the wastewater treatment plant is not necessary. However,sludge should be wasted from the aeration tank during wet weather to reduce the solids loading of the clarifiers and avoid effluent violations. Therefore,it is recommended that the design of wastewater treatment plants(WWTPs) should include flexibility to operate the plants in various modes. This is helpful in selection of the appropriate operating mode when necessary,resulting in substantial reductions in operating costs.
引用
收藏
页码:468 / 476
页数:9
相关论文
共 50 条
  • [1] Evaluation and improvement of wastewater treatment plant performance using BioWin
    Oloche James Oleyiblo
    Jiashun Cao
    Qian Feng
    Gan Wang
    Zhaoxia Xue
    Fang Fang
    Chinese Journal of Oceanology and Limnology, 2015, 33 : 468 - 476
  • [2] Evaluation and improvement of wastewater treatment plant performance using BioWin
    Oleyiblo, Oloche James
    Cao Jiashun
    Feng Qian
    Wang Gan
    Xue Zhaoxia
    Fang Fang
    CHINESE JOURNAL OF OCEANOLOGY AND LIMNOLOGY, 2015, 33 (02): : 468 - 476
  • [3] Improvement of wastewater treatment performance of the Fukashiba treatment plant
    Hirose, K.
    Igarashi, T.
    Ochiai, E.
    Seya, H.
    Matsui, S.
    WATER SCIENCE AND TECHNOLOGY, 2006, 53 (11) : 127 - 133
  • [4] Performance Evaluation of Wastewater Treatment Plant
    Prashant P. Bhave
    Shirish Naik
    Shubham D. Salunkhe
    Water Conservation Science and Engineering, 2020, 5 : 23 - 29
  • [5] Performance Evaluation of Wastewater Treatment Plant
    Bhave, Prashant P.
    Naik, Shirish
    Salunkhe, Shubham D.
    WATER CONSERVATION SCIENCE AND ENGINEERING, 2020, 5 (1-2) : 23 - 29
  • [6] Improvement of the Treatment Performance of the Conventional Wastewater Treatment Plant: A Case Study of the Central Wastewater Treatment Plant in Ulaanbaatar, Mongolia
    Nyamjav, Boldbaatar
    Badarch, Ayurzana
    Sangi, Chuluunkhuyag
    Khurelbaatar, Ganbaatar
    SUSTAINABILITY, 2023, 15 (05)
  • [7] Model based evaluation of plant improvement at a large wastewater treatment plant (WWTP)
    Drewnowski, Jakub
    Remiszewska-Skwarek, Anna
    Jesus Fernandez-Morales, Francisco
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2018, 53 (07): : 669 - 675
  • [8] Integrated wastewater treatment plant performance evaluation using artificial neural networks
    Hamoda, MF
    Al-Ghusain, IA
    Hassan, AH
    WATER SCIENCE AND TECHNOLOGY, 1999, 40 (07) : 55 - 65
  • [9] Implementing a respirometry-based model into BioWin software to simulate wastewater treatment plant operations
    Vitanza, Rosa
    Colussi, Iginio
    Cortesi, Angelo
    Gallo, Vittorino
    JOURNAL OF WATER PROCESS ENGINEERING, 2016, 9 : 267 - 275
  • [10] Performance evaluation of a smart buffer control at a wastewater treatment plant
    van Daal-Rombouts, P.
    Benedetti, L.
    de Jonge, J.
    Weijers, S.
    Langeveld, J.
    WATER RESEARCH, 2017, 125 : 180 - 190