Novel camera calibration method based on invariance of collinear points and pole–polar constraint

被引:0
|
作者
WEI Liang [1 ]
ZHANG Guiyang [2 ]
HUO Ju [1 ]
XUE Muyao [3 ]
机构
[1] School of Electrical Engineering and Automation, Harbin Institute of Technology
[2] School of Mechanical Engineering, Changshu Institute of Technology
[3] Space Propulsion Technology Research Institute, Shanghai Academy of Spaceflight Technology
基金
中国国家自然科学基金;
关键词
D O I
暂无
中图分类号
TP391.41 [];
学科分类号
080203 ;
摘要
To address the eccentric error of circular marks in camera calibration, a circle location method based on the invariance of collinear points and pole–polar constraint is proposed in this paper. Firstly, the centers of the ellipses are extracted,and the real concentric circle center projection equation is established by exploiting the cross ratio invariance of the collinear points. Subsequently, since the infinite lines passing through the centers of the marks are parallel, the other center projection coordinates are expressed as the solution problem of linear equations. The problem of projection deviation caused by using the center of the ellipse as the real circle center projection is addressed, and the results are utilized as the true image points to achieve the high precision camera calibration. As demonstrated by the simulations and practical experiments, the proposed method performs a better location and calibration performance by achieving the actual center projection of circular marks. The relevant results confirm the precision and robustness of the proposed approach.
引用
收藏
页码:744 / 753
页数:10
相关论文
共 50 条
  • [1] Novel camera calibration method based on invariance of collinear points and pole-polar constraint
    Wei, Liang
    Zhang, Guiyang
    Huo, Ju
    Xue, Muyao
    JOURNAL OF SYSTEMS ENGINEERING AND ELECTRONICS, 2023, 34 (03) : 744 - 753
  • [2] A Novel Camera Calibration Method Based on Polar Coordinate
    Gai, Shaoyan
    Da, Feipeng
    Fang, Xu
    PLOS ONE, 2016, 11 (10):
  • [3] Camera calibration method based on circular points
    Zhao, Lu-Gang
    Wu, Cheng-Ke
    Xi'an Dianzi Keji Daxue Xuebao/Journal of Xidian University, 2007, 34 (03): : 363 - 367
  • [4] A Camera Calibration Method Based on Free Points
    Zhang Jinglei
    Fan Kaibo
    Wang Yanjiao
    MECHANICAL AND ELECTRONICS ENGINEERING III, PTS 1-5, 2012, 130-134 : 1885 - 1888
  • [5] A novel method for camera calibration with orthogonal vanishing points
    Lu, Jin
    Sun, Huibin
    Chang, Zhiyong
    Zhongguo Jiguang/Chinese Journal of Lasers, 2014, 41 (02):
  • [6] A novel method for camera calibration using vanishing points
    He, B. W.
    Li, Y. F.
    14TH INTERNATIONAL CONFERENCE ON MECHATRONICS AND MACHINE VISION IN PRACTICE 2007, PROCEEDINGS, 2007, : 44 - +
  • [7] Calibration of camera intrinsic parameters based on the properties of the polar of circular points
    Yang, Fengli
    Zhao, Yue
    Wang, Xuechun
    APPLIED OPTICS, 2019, 58 (22) : 5901 - 5909
  • [8] Novel approach to circular points based camera calibration
    Wang, GH
    Wu, FC
    Hu, ZY
    SECOND INTERNATION CONFERENCE ON IMAGE AND GRAPHICS, PTS 1 AND 2, 2002, 4875 : 830 - 837
  • [9] A Camera Calibration Method Based on Plane Grid Points
    Zhang, Baofeng
    Tian, Xiuzhen
    Zhang, Xiaoling
    FRONTIERS OF MANUFACTURING SCIENCE AND MEASURING TECHNOLOGY, PTS 1-3, 2011, 230-232 : 723 - 727
  • [10] Research on Camera Calibration Method Based on Coplanar Points
    Li, Wenlong
    Wang, Wentao
    Cheng, Wei
    Ge, Hailong
    Jin, Shuo
    Ren, Yuan
    Ma, Xinqiang
    FIFTH INTERNATIONAL WORKSHOP ON PATTERN RECOGNITION, 2020, 11526