The Neutron-Gamma Pulse Shape Discrimination Method for Neutron Flux Detection in the ITER

被引:0
|
作者
徐修峰 [1 ,2 ]
李世平 [1 ,2 ]
曹宏睿 [1 ,2 ]
袁国梁 [3 ]
杨青巍 [3 ]
阴泽杰 [1 ,2 ]
机构
[1] University of Science and Technology of China
[2] State Key Lab Particle Detect & Elect
[3] Southwestern Institute of Physics
关键词
neutron pulse shape; rise time; NFM; ITER; n-γ PSD;
D O I
暂无
中图分类号
TL375 [实验与测量];
学科分类号
摘要
The neutron flux monitor (NFM), as a significant diagnostic system in the International Thermonuclear Experimental Reactor (ITER), will play an important role in the readings of a series of key parameters in the fusion reaction process. As the core of the main electronic system of the NFM, the neutron-gamma pulse shape discrimination (n-γ PSD) can distinguish the neutron pulse from the gamma pulse and other disturbing pulses according to the thresholds of the rising time and the amplitude pre-installed on the board, the double timing point CFD method is used to get the rising time of the pulse. The n-γ PSD can provide an accurate neutron count.
引用
收藏
页码:417 / 419
页数:3
相关论文
共 50 条
  • [1] The Neutron-Gamma Pulse Shape Discrimination Method for Neutron Flux Detection in the ITER
    徐修峰
    李世平
    曹宏睿
    袁国梁
    杨青巍
    阴泽杰
    Plasma Science and Technology, 2013, 15 (05) : 417 - 419
  • [2] The Neutron-Gamma Pulse Shape Discrimination Method for Neutron Flux Detection in the ITER
    Xu Xiufeng
    Li Shiping
    Cao Hongrui
    Yuan Guoliang
    Yang Qingwei
    Yin Zejie
    PLASMA SCIENCE & TECHNOLOGY, 2013, 15 (05) : 417 - 419
  • [3] DIGITAL TECHNIQUE FOR NEUTRON-GAMMA PULSE SHAPE DISCRIMINATION
    MORRIS, CL
    BOLGER, JE
    HOFFMANN, GW
    MOORE, CF
    SMITH, LE
    THIESSEN, HA
    NUCLEAR INSTRUMENTS & METHODS, 1976, 137 (02): : 397 - 398
  • [4] The Neutron-Gamma Pulse Shape Discrimination of CLLB Detector
    Song, Ruiqiang
    Peng, Shuo
    Tong, Yufeng
    Wu, Qi
    Qian, Sen
    Wang, Zhigang
    Han, Jifeng
    26TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS, CHEP 2023, 2024, 295
  • [5] PULSE SHAPE ANALYZER FOR FAST NEUTRON-GAMMA RAY DISCRIMINATION
    BRIENT, CE
    YOUNG, RL
    NELSON, CE
    NUCLEAR INSTRUMENTS & METHODS, 1972, 98 (02): : 329 - &
  • [6] A neutron-gamma pulse shape discrimination method based on pure and mixed sources
    Kaplan, Alan D.
    Blair, Brenton
    Chen, Cliff
    Glenn, Andrew
    Ruz, Jaime
    Wurtz, Ron
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 919 : 36 - 41
  • [7] FINE STRUCTURE IN NEUTRON-GAMMA RAY PULSE SHAPE DISCRIMINATION
    STONGE, R
    AMOS, TM
    GALONSKY, A
    JOLLY, RK
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1971, 16 (10): : 1172 - &
  • [8] Performance stability of plastics for neutron-gamma pulse shape discrimination
    Zaitseva, Natalia
    Carman, Leslie
    Glenn, Andrew
    Kim, Yongwook
    Ford, Michael
    Eccleston, Gracie
    Hurlbut, Charles
    Shipp, Kyle
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2024, 1068
  • [9] Triplet Harvesting Plastic Scintillators with Neutron-Gamma Pulse Shape Discrimination
    van Loef, Edgar V.
    Feng, Patrick
    Markosyan, Gary
    Shirwadkar, Urmila
    Doty, Patrick
    Shah, Kanai S.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XVI, 2014, 9213
  • [10] NEUTRON-GAMMA PULSE SHAPE-DISCRIMINATION AT HIGH COUNT RATES
    PIERCEY, RB
    MCKISSON, JE
    BANDA, MAH
    SHAVERS, MR
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1987, 34 (01) : 82 - 84