Thiel-embalming technique:investigation of possible modification in embalming tissue as evaluation model for radiofrequency ablation

被引:0
|
作者
Peiyu Liao [1 ,2 ,3 ,4 ]
Zhigang Wang [1 ]
机构
[1] Institute for Medical Science and Technology, University of Dundee
[2] School of Engineering, Physics and Mathematics, University of Dundee
[3] College of Chemistry and Chemical Engineering, Hunan University
[4] College of Engineering, Peking University
关键词
Cadaver embalmment; Thiel’s embalming fluid; electrical conductivity; radiofrequency ablation;
D O I
暂无
中图分类号
R322-3 [人体解剖学研究方法];
学科分类号
100101 ;
摘要
Contrary to freezing preservation and formalin embalming,Thiel embalmed cadaver presents soft texture and color very close to that of living organism,and many applications based on Thiel embalmed cadavers have been reported.However,Thiel embalmed cadavers cannot be used as reliable evaluation model for radiofrequency ablation(RFA)due to dramatic changes of electrical conductivity in the embalmed tissue.To address this issue,we investigated various modifications of the original Thiel embalming solution.By altering the chemicals’ species and concentration we figured out a formula that can greatly reduce the embalming fluid’s electrical conductivity without significantly compromising the 18-day embalmed kidney samples’ suppleness and color.We also investigated a two-stage embalming technique by first submerging the kidney sample into original Thiel’s tank fluid for 28 days,then the sample was withdrawn from the tank fluid and placed into modified dilution fluids for additional two weeks.Stiffening and discoloration occurred in these diluted samples implying the reversibility of Thiel-embalmed tissues’ suppleness and color with the removal of the strong electrolytes.This study presents a modified embalming method which could be used for RPA evaluation and also helps our understanding of the mechanism of embalmment process.
引用
收藏
页码:280 / 288
页数:9
相关论文
共 3 条
  • [1] Thiel-embalming technique: investigation of possible modification in embalming tissue as evaluation model for radiofrequency ablation
    Liao, Peiyu
    Wang, Zhigang
    JOURNAL OF BIOMEDICAL RESEARCH, 2019, 33 (04): : 280 - 288
  • [2] An Experimental Model for Training in Renal Transplantation Surgery With Human Cadavers Preserved Using W. Thiel's Embalming Technique
    Cabello, Ramiro
    Gonzalez, Carmen
    Quicios, Cristina
    Bueno, Gonzalo
    Garcia, Juan V.
    Arribas, Ana B.
    Clasca, Francisco
    JOURNAL OF SURGICAL EDUCATION, 2015, 72 (02) : 192 - 197
  • [3] Electrical conductivity measurement in Thiel-embalmed tissue model: relevance to radiofrequency ablation
    Wang, Zhigang
    Luo, Hongyan
    Nick, M.
    Gueorguieva, M.
    Andre, P.
    Baker, R. T.
    McLean, D.
    Brown, S.
    Cuschieri, A.
    ELECTRONICS LETTERS, 2014, 50 (16) : 1125 - 1126