Baseline optimization of SQUID gradiometer for magnetocardiography

被引:1
|
作者
李华 [1 ,2 ,3 ]
张树林 [1 ,2 ]
邱阳 [1 ,2 ,3 ]
张永升 [1 ,2 ]
张朝祥 [1 ,2 ]
孔祥燕 [1 ,2 ]
谢晓明 [1 ,2 ]
机构
[1] State Key Laboratory of Functional Materials for Informatics,Shanghai Institute of Microsystem and Information Technology(SIMIT),Chinese Academy of Sciences(CAS)
[2] Joint Research Laboratory on Superconductivity and Bioelectronics,Collaboration Between CAS-Shanghai
[3] University of Chinese Academy of Sciences
关键词
SQUID; gradiometer; baseline optimization; magnetocardiography;
D O I
暂无
中图分类号
O441 [电磁学];
学科分类号
0809 ;
摘要
SQUID gradiometer techniques are widely used in noise cancellation for biomagnetic measurements.An appropriate gradiometer baseline is very important for the biomagnetic detection with high performance.By placing several magnetometers at different heights along the vertical direction,we could simultaneously obtain the synthetic gradiometers with different baselines.By using the traditional signal-to-noise ratio(SNR) as a performance index,we successfully obtain an optimal baseline for the magnetocardiography(MCG) measurement in a magnetically shielded room(MSR).Finally,we obtain an optimal baseline of 7 cm and use it for the practical MCG measurement in our MSR.The SNR about 38 dB is obtained in the recorded MCG signal.
引用
收藏
页码:475 / 477
页数:3
相关论文
共 50 条
  • [1] Baseline optimization of SQUID gradiometer for magnetocardiography
    Li Hua
    Zhang Shu-Lin
    Qiu Yang
    Zhang Yong-Sheng
    Zhang Chao-Xiang
    Kong Xiang-Yan
    Xie Xiao-Ming
    CHINESE PHYSICS B, 2015, 24 (02)
  • [2] A Modeling Method for Synthetic SQUID Gradiometer With Optimized Baseline in Magnetocardiography Measurement
    Yang, Kang
    Zhao, Ahui
    Zhang, Yongle
    Zhang, Qiannian
    Zhang, Hongwei
    Wang, Xiang
    Rui, Daorong
    Huang, Dengchao
    Kong, Xiangyan
    IEEE SENSORS JOURNAL, 2024, 24 (10) : 15986 - 15993
  • [3] First-order SQUID Gradiometer with Electronic Subtraction for Magnetocardiography
    Carmina, Rau Miuta
    Octavian, Baltag
    PROCEEDINGS OF THE 2012 INTERNATIONAL CONFERENCE AND EXPOSITION ON ELECTRICAL AND POWER ENGINEERING (EPE 2012), 2012, : 577 - 580
  • [4] Weakly Damped SQUID Gradiometer With Low Crosstalk for Magnetocardiography Measurement
    Yang, Kang
    Chen, Hua
    Kong, Xiangyan
    Lu, Li
    Li, Ming
    Yang, Ruihu
    Xie, Xiaoming
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2016, 26 (08)
  • [5] High-Tc SQUID gradiometer system for magnetocardiography in an unshielded environment
    Liao, SH
    Hsu, SC
    Lin, CC
    Horng, HE
    Chen, JC
    Chen, MJ
    Wu, CH
    Yang, HC
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2003, 16 (12): : 1426 - 1429
  • [6] OPTIMIZATION OF A SQUID VECTOR GRADIOMETER
    LEKKALA, JO
    MALMIVUO, JAV
    CRYOGENICS, 1985, 25 (06) : 291 - 303
  • [7] Foetal magnetocardiography with a multi-channel HTS rf SQUID gradiometer
    Zhang, Y.
    Wolters, N.
    Lomparski, D.
    Zander, W.
    Banzet, M.
    Schubert, J.
    Krause, H-J
    Geue, D.
    van Leeuwen, P.
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 2006, 19 (05): : S266 - S270
  • [8] SQUID Gradiometer Module for Fetal Magnetocardiography Measurements Inside a Thin Magnetically Shielded Room
    Wang, Jialei
    Yang, Kang
    Yang, Ruihu
    Kong, Xiangyan
    Chen, Wei
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2019, 29 (02)
  • [9] Achieving magnetocardiography map by using a single channel high Tc rf SQUID gradiometer
    Ma, P
    Yao, K
    Xie, FX
    Zhang, SY
    Deng, P
    He, DF
    Zhang, F
    Liu, LY
    Nie, RJ
    Wang, FR
    Wang, SZ
    Dai, YD
    ACTA PHYSICA SINICA, 2002, 51 (02) : 224 - 227
  • [10] Measurements of the magnetocardiography in unshielded environment using high-Tc rf SQUID gradiometer
    He, DF
    Zhang, F
    Xie, FX
    Dai, YD
    Wang, SG
    Ma, P
    Yang, T
    Wang, SZ
    Chen, WC
    Wang, ZQ
    PHYSICA C, 2000, 341 : 2635 - 2636