Study on element detection and its correction in iron ore concentrate based on a prompt gamma-neutron activation analysis system

被引:0
|
作者
Long Zhao [1 ,2 ]
Xu Xu [1 ]
Jing-Bin Lu [1 ]
Ya-Lin Gong [2 ]
Xiang-Lin Li [3 ]
Wei Zhang [2 ]
Qing-Min Shang [2 ]
Qing-Feng Song [2 ]
Yan-Feng Li [2 ]
机构
[1] College of Physics, Jilin University
[2] Dandong Dongfang Measurement & Control Technology Co., Ltd
[3] Hunan First Normal University
关键词
Prompt gamma-neutron activation analysis; Self-absorption; Energy spectrum; Compensation; Correction; Iron ore concentrate;
D O I
暂无
中图分类号
O652 [分析作业方法与技术]; P575 [矿物的鉴定及分析];
学科分类号
070302 ; 070901 ; 081704 ;
摘要
A prompt gamma-neutron activation analysis(PGNAA) system was developed to detect the iron content of iron ore concentrate. Because of the self-absorption effect of gamma-rays and neutrons, and the interference of chlorine in the neutron field, the linear relationship between the iron analytical coefficient and total iron content was poor, increasing the error in the quantitative analysis. To solve this problem, gamma-ray self-absorption compensation and a neutron field correction algorithm were proposed, and the experimental results have been corrected using this algorithm. The results show that the linear relationship between the iron analytical coefficient and total iron content was considerably improved after the correction. The linear correlation coefficients reached 0.99 or more.
引用
收藏
页码:19 / 27
页数:9
相关论文
共 50 条
  • [1] Study on element detection and its correction in iron ore concentrate based on a prompt gamma-neutron activation analysis system
    Long Zhao
    Xu Xu
    Jing-Bin Lu
    Ya-Lin Gong
    Xiang-Lin Li
    Wei Zhang
    Qing-Min Shang
    Qing-Feng Song
    Yan-Feng Li
    Nuclear Science and Techniques, 2019, 30
  • [2] Study on element detection and its correction in iron ore concentrate based on a prompt gamma-neutron activation analysis system
    Zhao, Long
    Xu, Xu
    Lu, Jing-Bin
    Gong, Ya-Lin
    Li, Xiang-Lin
    Zhang, Wei
    Shang, Qing-Min
    Song, Qing-Feng
    Li, Yan-Feng
    NUCLEAR SCIENCE AND TECHNIQUES, 2019, 30 (04)
  • [3] COLD NEUTRON FACILITY FOR PROMPT GAMMA-NEUTRON ACTIVATION-ANALYSIS
    MOLNAR, G
    REVAY, ZS
    VERES, A
    SIMONITS, A
    RAUSCH, H
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1993, 167 (01): : 133 - 137
  • [4] ELEMENTAL COMPOSITION OF COAL BY USING PROMPT GAMMA-NEUTRON ACTIVATION-ANALYSIS
    OLIVEIRA, C
    SALGADO, J
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1993, 167 (01): : 153 - 160
  • [5] Stability evaluation and correction of a pulsed neutron generator prompt gamma activation analysis system
    Roman J. Shypailo
    Journal of Radioanalytical and Nuclear Chemistry, 2016, 307 : 1781 - 1786
  • [6] Stability evaluation and correction of a pulsed neutron generator prompt gamma activation analysis system
    Shypailo, Roman J.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2016, 307 (03) : 1781 - 1786
  • [7] On Multi-Element Spectrum of Prompt Gamma Neutron Activation Analysis
    Wang, Qibiao
    Tuo, Xianguo
    Yang, Jianbo
    Cheng, Yi
    Cai, Ting
    Wang, Xu
    INTERNATIONAL SYMPOSIUM ON SIGNAL PROCESSING BIOMEDICAL ENGINEERING, AND INFORMATICS (SPBEI 2013), 2014, : 522 - 529
  • [8] Preliminary study of prompt gamma neutron activation analysis for Melamine
    Ishak, Muhamad Noor Izwan
    Sipaun, Susan Maria
    Dahing, Normanshah
    Hassan, Haerie
    Abdullah, Nurliyana
    INTERNATIONAL NUCLEAR SCIENCE TECHNOLOGY AND ENGINEERING CONFERENCE 2019 (INUSTEC2019), 2020, 785
  • [9] Neutron self-shielding correction for prompt gamma neutron activation analysis of large samples
    Blaauw, M
    Belgya, T
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 265 (02) : 257 - 259
  • [10] Neutron self-shielding correction for prompt gamma neutron activation analysis of large samples
    M. Blaauw
    T. Belgya
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 265 : 257 - 259