Field validation of generic wind park models using fault records

被引:0
|
作者
Aboutaleb HADDADI [1 ]
Ilhan KOCAR [1 ]
Thomas KAUFFMANN [1 ]
Ulas KARAAGAC [2 ]
Evangelos FARANTATOS [3 ]
Jean MAHSEREDJIAN [1 ]
机构
[1] Polytechnique Montreal
[2] The Hong Kong Polytechnic University
[3] Electric Power Research Institute(EPRI),Palo Alto,
关键词
Renewable generation; Wind turbine generator; Doubly-fed induction generator; Short-circuit analysis; Electromagnetic transient-type model; Phasor domain model;
D O I
暂无
中图分类号
TM614 [风能发电];
学科分类号
0807 ;
摘要
A challenge faced by protection and planning engineers is the development and validation of accurate wind turbine generator(WTG) models to study the impact of increasing wind integration on system protection. Thispaper is on the experimental validation of a generic electromagnetic transient-type(EMT-type) model of aggregated WTGs or wind parks suitable for transient studies.The phasor domain equivalent of the generic model, suitable for protection tools based on steady-state solvers, is also considered. The model has been validated using two sets of actual relay records for the fault response of two wind parks consisting of Type-III WTGs and connected to115 kV and 230 kV transmission systems. The objective is to show that the generic model can reproduce the actual fault response in simulations, and protection engineers can obtain accurate models of wind parks using fault records. A distinctive characteristic of a WTG is its substantially different negative sequence fault current contribution compared to a synchronous generator. The paper shows that the generic model provides enough options to reproduce the negative sequence behavior and hence is suitable for fault studies involving negative sequence-based protection.
引用
收藏
页码:826 / 836
页数:11
相关论文
共 13 条
  • [1] Doubly-fed induction generator-based wind park models in EMTP-RV. Karaagac U,Saad H,Peralta J et al. . 2016
  • [2] On a new approach for the simulation of transients in power systems[J] . J. Mahseredjian,S. Dennetière,L. Dubé,B. Khodabakhchian,L. Gérin-Lajoie. &nbspElectric Power Systems Research . 2006 (11)
  • [3] Grid converters for photovoltaic and wind power systems. Teodorescu R,Liserre M,Rodriguez P. . 2011
  • [4] An accurate type III wind turbine generator short circuit model for protection applications. Kauffmann T,Karaagac U,Kocar I et al. IEEE Transactions on Power Delivery . 2017
  • [5] Phasor domain modeling of type III wind turbine generator for protection studies. Kauffmann T,Karaagac U,Kocar I et al. Proceedings of IEEE PES general meeting . 2015
  • [6] Wind turbine negative sequence current control and its effect on power system protection. Erlich I,Neumann T,Shewarega F et al. Proceedings of IEEE PES general meeting . 2013
  • [7] Modeling of wind parks for steady state short circuit studies. Kauffmann T. . 2018
  • [8] Fault current contributions from wind plants. Barsch J,Bartok G,Benmouya G et al. Proceedings of annual conference for protective relay engineers . 2015
  • [9] System protection guidelines for systems with high levels of renewables:impact of wind and solar generation on negative-sequence and power swing protection. Haddadi A,Kocar I,Farantatos E et al. . 2017
  • [10] Short-circuit phasor models of converter-based renewable energy resources for fault studies. Kocar I,Kauffmann T,Karaagac U et al. . 2017