Equivalent magnetic dipole method used to design gradient coil for unilateral magnetic resonance imaging

被引:0
|
作者
徐征 [1 ]
李想 [1 ]
郭盼 [2 ]
吴嘉敏 [1 ]
机构
[1] State Key Laboratory of Power Transmission Equipment & System Security and New Technology,Chongqing University
[2] School of Physics and Electronic Engineering,Chongqing Normal University
基金
中国国家自然科学基金;
关键词
unilateral MRI; equivalent magnetic dipole method; gradient coil; current density distribution;
D O I
暂无
中图分类号
O482.532 [];
学科分类号
摘要
The conventional magnetic resonance imaging(MRI) equipment cannot measure large volume samples nondestructively in the engineering site for its heavy weight and closed structure. In order to realize the mobile MRI, this study focuses on the design of gradient coil of unilateral magnet. The unilateral MRI system is used to image the local area above the magnet. The current density distribution of the gradient coil cannot be used as a series of superconducting nuclear magnetic resonance gradient coils, because the region of interest(ROI) and the wiring area of the unilateral magnet are both cylindrical side arc surfaces. Therefore, the equivalent magnetic dipole method is used to design the gradient coil, and the algorithm is improved for the special case of the wiring area and the ROI, so the X and Y gradient coils are designed.Finally, a flexible printed circuit board(PCB) is used to fabricate the gradient coil, and the magnetic field distribution of the ROI is measured by a Gauss meter, and the measured results match with the simulation results. The gradient linearities of x and y coils are 2.82% and 3.56%, respectively, less than 5% of the commercial gradient coil requirement.
引用
收藏
页码:549 / 554
页数:6
相关论文
共 50 条
  • [1] Equivalent magnetic dipole method used to design gradient coil for unilateral magnetic resonance imaging
    Xu, Zheng
    Li, Xiang
    Guo, Pan
    Wu, Jia-Min
    CHINESE PHYSICS B, 2018, 27 (05)
  • [2] Equivalent magnetic dipole method for designing gradient coils of the Halbach magnetic resonance device
    Xu, Zheng
    Qi, Jinfeng
    Guo, Pan
    Cui, Xianjun
    Wu, Jiamin
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2018, 56 (04) : 595 - 604
  • [3] Shim coil design for Halbach magnet by equivalent magnetic dipole method
    吴嘉敏
    徐征
    郭盼
    戚金凤
    贺玉成
    Chinese Physics B, 2018, 27 (10) : 304 - 311
  • [4] Shim coil design for Halbach magnet by equivalent magnetic dipole method
    Wu, Jia-Min
    Xu, Zheng
    Guo, Pan
    Qi, Jin-Feng
    He, Yu-Cheng
    CHINESE PHYSICS B, 2018, 27 (10)
  • [5] Theory of Gradient Coil Design Methods for Magnetic Resonance Imaging
    Hidalgo-Tobon, S. S.
    CONCEPTS IN MAGNETIC RESONANCE PART A, 2010, 36A (04) : 223 - 242
  • [6] Equivalent Magnetization Current Method Applied to the Design of Gradient Coils for Magnetic Resonance Imaging
    Lopez, Hector Sanchez
    Liu, Feng
    Poole, Michael
    Crozier, Stuart
    IEEE TRANSACTIONS ON MAGNETICS, 2009, 45 (02) : 767 - 775
  • [7] Design and implementation of uniplanar gradient field coil for magnetic resonance imaging
    Lemdiasov, RA
    Ludwig, R
    IEEE TRANSACTIONS ON MAGNETICS, 2004, 40 (04) : 1939 - 1943
  • [8] Design and implementation of a uniplanar gradient field coil for magnetic resonance imaging
    Lemdiasov, R
    Ludwig, R
    Brevard, M
    Ferris, C
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2004, 20B (01) : 17 - 29
  • [9] Magnetic resonance imaging gradient coil design by combining optimization techniques with the finite element method
    Shi, FN
    Ludwig, R
    IEEE TRANSACTIONS ON MAGNETICS, 1998, 34 (03) : 671 - 683
  • [10] An open transverse z-gradient coil design for magnetic resonance imaging
    Dodd, SJ
    Williams, DS
    Olson, C
    Silva, AC
    Koretsky, AP
    Ho, C
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2002, 73 (05): : 2208 - 2210