Radiographic verification of pedicle screw pilot hole placement in thoracic spine using Kirschner wires versus spiral wires

被引:0
|
作者
刘一
张绍昆
苗巍巍
单玉兴
孙大辉
王柏
李印良
黄晓刚
机构
[1] Jilin Province 130061
[2] Department of Radiology
[3] Jilin University
[4] Jilin University Changchun
[5] First Hospital
[6] Department of Orthopaedic Surgery
[7] Changchun
[8] Jilin Province 130021
[9] China
[10] Second Hospital
关键词
Thoracic vertebrae; Bone screws; Kirschner wires;
D O I
暂无
中图分类号
R816.8 [外科、骨科];
学科分类号
1001 ; 100105 ; 100207 ; 100602 ;
摘要
Objective: To evaluate the feasibility of the pedicle screw pilot holes placement in thoracic spine using the spiral wires as the guide pin. Methods: The pedicle screw pilot holes were drilled within the center of the pedicle and the lateral and medial pedicle walls were violated in 9 human dried thoracic vertebrae. Kirschner wires or spiral wires were separately placed in the holes, and then the posteroanterior and lateral radiographs were taken. The radiographs were evaluated by 3 experienced spine surgeons and 3 young orthopedists. After radiographs were shown to these observers, they combined the posteroanterior and lateral radiographs in each place and determined whether the pedicle screw pilot hole violated the pedicle cortex or not. The results were analyzed by a statistical software. Results: Sensitivity, specificity and accuracy of the method using spiral wires to detect pedicle pilot hole placement were significantly higher than those of using Kirschner wires. With a true posteroanterior radiograph, the sensitivity, specificity and accuracy of the method using spiral wires approximated or attained 100%. Conclusions: The method of intrapedicular pilot hole placement verification using spiral wires is effective for guiding the accurate placement of pedicle screws.
引用
收藏
页码:33 / 36
页数:4
相关论文
共 14 条
  • [1] Radiographic verification of pedicle screw pilot hole placement in thoracic spine using Kirschner wires versus spiral wires
    刘一
    张绍昆
    苗巍巍
    单玉兴
    孙大辉
    王柏
    李印良
    黄晓刚
    ChineseJournalofTraumatology, 2003, (05)
  • [2] Radiographic verification of pedicle screw pilot hole placement using Kirshner wires versus beaded wires
    Myles, RT
    Fong, B
    Esses, SI
    Hipp, JA
    SPINE, 1999, 24 (05) : 476 - 480
  • [3] Percutaneous pedicle screw placement with computer-navigated mapping in place of Kirschner wires
    Gianaris, Thomas J.
    Helbig, Gregory M.
    Horn, Eric M.
    JOURNAL OF NEUROSURGERY-SPINE, 2013, 19 (05) : 608 - 613
  • [4] Free Hand Pedicle Screw Placement in the Thoracic Spine without Any Radiographic Guidance: Technical Note, a Cadaveric Study
    Hyun, Seung-Jae
    Kim, Yongjung J.
    Cheh, Gene
    Yoon, Seung Hwan
    Rhim, Seung-Chul
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2012, 51 (01) : 66 - 70
  • [5] Effects of pilot hole preparation technique on pedicle screw fixation in different regions of the osteoporotic thoracic and lumbar spine
    Carmouche, JJ
    Molinari, RW
    Gerlinger, T
    Devine, J
    Patience, T
    JOURNAL OF NEUROSURGERY-SPINE, 2005, 3 (05) : 364 - 370
  • [6] The accuracy of pedicle screw placement in the thoracic spine using the "funnel technique" - Part 1. A cadaveric study
    Yingsakmonkol, W
    Karaikovic, T
    Gaines, RW
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2002, 15 (06): : 445 - 449
  • [7] Radiographic Accuracy of Percutaneous Pedicle Screw Placement in Fluoroscopic- Versus CT Navigation-Guided Lumbar Spine Instrumentation
    Cong, Guang-Ting
    Vaishnav, Avani
    Barbera, Joseph
    Kumagai, Hiroshi
    Dowdell, James
    Gang, Catherine
    Qureshi, Sheeraz
    NEUROSURGERY, 2019, 66 : 128 - 128
  • [8] Anatomic considerations of pedicle screw placement in the thoracic spine Roy-Camille technique versus open-lamina technique
    Xu, RM
    Ebraheim, NA
    Ou, YJ
    Yeasting, RA
    SPINE, 1998, 23 (09) : 1065 - 1068
  • [9] Accuracy of pedicle screw placement in thoracic spine fractures - Part II: A retrospective analysis of 278 pedicle screws using computed tomographic scans
    Zdichavsky M.
    Blauth M.
    Knop C.
    Lotz J.
    Krettek C.
    Bastian L.
    European Journal of Trauma, 2004, 30 (4): : 241 - 247
  • [10] Accuracy of pedicle screw placement using neuronavigation based on intraoperative 3D rotational fluoroscopy in the thoracic and lumbar spine
    Conrads, Nora
    Grunz, Jan-Peter
    Huflage, Henner
    Luetkens, Karsten Sebastian
    Feldle, Philipp
    Grunz, Katharina
    Koehler, Stefan
    Westermaier, Thomas
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (06) : 3007 - 3013