Combined Effects of Moderate Hypoxia and Sleep Restriction on Mental Workload

被引:1
|
作者
Pontiggia, Anais [1 ,2 ]
Fabries, Pierre [1 ,3 ]
Beauchamps, Vincent [1 ,2 ,3 ]
Quiquempoix, Michael [1 ,2 ]
Nespoulous, Olivier [1 ]
Jacques, Clementine [2 ,4 ]
Guillard, Mathias [1 ,2 ]
Van Beers, Pascal [1 ,2 ]
Ayounts, Haik [1 ,2 ]
Koulmann, Nathalie [3 ]
Gomez-Merino, Danielle [1 ,2 ]
Chennaoui, Mounir [1 ,2 ]
Sauvet, Fabien [1 ,2 ,3 ]
机构
[1] Armed Forces Biomed Res Inst IRBA, F-91220 Bretigny Sur Orge, France
[2] Univ Paris Cite, VIFASOM, URP 7330, F-75004 Paris, France
[3] Ecole Val De Grace EVDG, F-75005 Paris, France
[4] THALES SIX GTS, Lab Theresis, F-91190 Palaiseau, France
来源
CLOCKS & SLEEP | 2024年 / 6卷 / 03期
关键词
hypoxia; sleep restriction; MATB-II; auditory oddball; ECG; eye tracking; breathing rate; SpO(2); COGNITIVE PERFORMANCE; SUSTAINED ATTENTION; DEPRIVATION; RESPONSES; ALTITUDE; VIGILANCE; SELECTION; SIMULATOR; BENEFITS; QUALITY;
D O I
10.3390/clockssleep6030024
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Aircraft pilots face a high mental workload (MW) under environmental constraints induced by high altitude and sometimes sleep restriction (SR). Our aim was to assess the combined effects of hypoxia and sleep restriction on cognitive and physiological responses to different MW levels using the Multi-Attribute Test Battery (MATB)-II with an additional auditory Oddball-like task. Seventeen healthy subjects were subjected in random order to three 12-min periods of increased MW level (low, medium, and high): sleep restriction (SR, <3 h of total sleep time (TST)) vs. habitual sleep (HS, >6 h TST), hypoxia (HY, 2 h, FIO2 = 13.6%, similar to 3500 m vs. normoxia, NO, FIO2 = 21%). Following each MW level, participants completed the NASA-TLX subjective MW scale. Increasing MW decreases performance on the MATB-II Tracking task (p = 0.001, MW difficulty main effect) and increases NASA-TLX (p = 0.001). In the combined HY/SR condition, MATB-II performance was lower, and the NASA-TLX score was higher compared with the NO/HS condition, while no effect of hypoxia alone was observed. In the accuracy of the auditory task, there is a significant interaction between hypoxia and MW difficulty (F(2-176) = 3.14, p = 0.04), with lower values at high MW under hypoxic conditions. Breathing rate, pupil size, and amplitude of pupil dilation response (PDR) to auditory stimuli are associated with increased MW. These parameters are the best predictors of increased MW, independently of physiological constraints. Adding ECG, SpO(2), or electrodermal conductance does not improve model performance. In conclusion, hypoxia and sleep restriction have an additive effect on MW. Physiological and electrophysiological responses must be taken into account when designing a MW predictive model and cross-validation.
引用
收藏
页码:338 / 358
页数:21
相关论文
共 50 条
  • [1] Additive effects of moderate hypoxia and sleep restriction on mental workload
    Sauvet, Fabien
    Anais, Pontiggia
    Pierre, Fabries
    Vincent, Beauchamps
    Michael, Quiquempoix
    Danielle, Gomez-Merino
    Mounir, Chennaoui
    JOURNAL OF SLEEP RESEARCH, 2024, 33
  • [2] COMBINED EFFECTS OF HIGH COGNITIVE WORKLOAD AND SLEEP RESTRICTION ON BEHAVIORAL ALERTNESS
    Braun, M. E.
    Goel, N.
    Jones, C. W.
    Dinges, D. F.
    SLEEP, 2011, 34 : A102 - A102
  • [3] Isolated and Combined Effects of Moderate Normobaric Hypoxia and Sleep Restriction on Energy Intake and Food Reward on Behalf of the HYPSOM Investigator Group
    Clave, Paco
    Fabries, Pierre
    Beauchamps, Vincent
    Pontiggia, Anais
    David, Louis
    Van Beers, Pascal
    Guillard, Mathias
    Tavard, Blandine
    Malgoyre, Alexandra
    Koulmann, Nathalie
    Gomez-Merino, Danielle
    Sauvet, Fabien
    Chennaoui, Mounir
    Charlot, Keyne
    INTERNATIONAL JOURNAL OF SPORT NUTRITION AND EXERCISE METABOLISM, 2025, 35 (01) : 51 - 60
  • [4] EFFECTS OF COGNITIVE WORKLOAD AND SLEEP RESTRICTION ON THE MAINTENANCE OF WAKEFULNESS TEST
    Arroyo, S.
    Goel, N.
    Dinges, D. F.
    SLEEP, 2011, 34 : A102 - A102
  • [5] THE EFFECTS OF COGNITIVE WORKLOAD AND SLEEP RESTRICTION ON THE MAINTENANCE OF WAKEFULNESS TEST
    Muto, J. A.
    Banks, S.
    Goel, N.
    Basner, M.
    Dinges, D. F.
    SLEEP, 2010, 33 : A101 - A101
  • [6] THE EFFECTS OF COGNITIVE WORKLOAD DURING SLEEP RESTRICTION ON POLYSOMNOGRAPHIC MEASURES
    Di Antonio, A.
    Goel, N.
    Banks, S.
    Basner, M.
    Dinges, D. F.
    SLEEP, 2010, 33 : A101 - A101
  • [7] THE EFFECTS OF COGNITIVE WORKLOAD DURING SLEEP RESTRICTION ON EXECUTIVE FUNCTION MEASURES
    Moreta, M. C.
    Goel, N.
    Banks, S.
    Basner, M.
    Dinges, D. F.
    SLEEP, 2010, 33 : A100 - A100
  • [8] THE EFFECTS OF COGNITIVE WORKLOAD DURING SLEEP RESTRICTION ON SUBJECTIVE SLEEPINESS AND FATIGUE
    McGinley, S. T.
    Goel, N.
    Banks, S.
    Basner, M.
    Dinges, D. F.
    SLEEP, 2010, 33 : A100 - A101
  • [9] NEUROBEHAVIORAL AND PHYSIOLOGICAL EFFECTS OF HIGH COGNITIVE WORKLOAD AND CHRONIC SLEEP RESTRICTION
    Braun, M. E.
    Goel, N.
    Dinges, D. F.
    SLEEP, 2012, 35 : A107 - A107
  • [10] THE EFFECTS OF COGNITIVE WORKLOAD DURING SLEEP RESTRICTION ON THE 10-MINUTE PVT
    Jones, C. W.
    Goel, N.
    Banks, S.
    Basner, M.
    Dinges, D. F.
    SLEEP, 2010, 33 : A100 - A100