Radial mixing in horizontal aerated tubular reactor

被引:0
|
作者
Pronczuk, Mateusz R. [1 ]
机构
[1] Cracow Univ Technol, Fac Chem Engn & Technol, Ul Warszawska 24, PL-30155 Krakow, Poland
关键词
horizontal aerated tubular reactor; radial dispersion; radial mixing; mixing time; optical measurements; AXIAL-DISPERSION; AIRLIFT; BIOREACTORS;
D O I
10.2478/pjct-2024-0044
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
The article discusses radial mixing in a Horizontal Aerated Tubular Reactor (HATR). The study aimed to experimentally investigate mixing in HATR by determining mixing time, liquid circulation time, and Peclet number values, which measure the ratio of advective to diffusive transport rates. The experimental setup included a transparent tube for observing fluid mixing and a color tracer was used for visualizing mixing. Mixing and circulation times were determined using non-intrusive optical method. The experimentally determined circulation time was in the range of 3 divided by 6.5 s, and the mixing time was in the range of 5 divided by 20 s. The results suggested that fluid flow structure in HATR was closer to plug flow rather than ideal mixing, as indicated by high Peclet numbers (20 divided by 45).
引用
收藏
页码:87 / 96
页数:10
相关论文