Life Cycle Assessment and Exergoenvironmental Analysis of a Double-Effect Vapor Absorption Chiller Using Green Hydrogen, Natural Gas, and Biomethane

被引:0
|
作者
Neto, Joao Luiz de Medeiros [1 ]
De Souza, Ronelly Jose [2 ]
dos Santos, Carlos Antonio Cabral [1 ]
de Carvalho, Jeane Batista [3 ]
Alves, Daniel Nicolau Lima [3 ]
机构
[1] Univ Fed Paraiba, Dept Mech Engn, Cidade Univ S-N, BR-58051900 Joao Pessoa, PB, Brazil
[2] Univ Trieste, Dept Engn & Architecture, Trieste, I-34127, Italy
[3] Univ Estadual Santa Cruz, DEC Dept Engn & Comp, Campus Soane Nazare de Andrade,Rod Jorge Amado,Km, BR-45662900 Ilheus, BA, Brazil
关键词
absorption refrigeration; life cycle assessment; exergoenvironmental assessment; energy sources; environmental impact; RENEWABLE ENERGY; NORTHEAST BRAZIL; EXERGY; IMPACT;
D O I
10.3390/su17010063
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study conducts a life cycle assessment and exergoenvironmental evaluation of a double-effect vapor absorption chiller (DEAC) with a cooling capacity of 352 kW, employing three different energy sources: natural gas, biomethane, and green hydrogen. The main objectives of this paper are as follows: (i) provide an exergoenvironmental model for DEAC technologies, (ii) evaluation of a case-study where a DEAC is used to cover the cooling demand of a specific university building in the Northeast of Brazil, and (iii) evaluate the scenario where the DEAC is fed by green hydrogen (GH2) and compare it with conventional energy resources (natural gas and biomethane). In order to develop the exergoenvironmental model, two methodologies are essential: a thermodynamic analysis and a Life Cycle Assessment (LCA). The thermodynamic analysis was carried out using the Engineering Equation Solver (EES: 10.998) software. The LCA has been developed through the open-source software openLCA version 1.10.3, with the Ecoinvent 3.7.1 life cycle inventory database, whereas the chosen life cycle inventory assessment (LCIA) method was the ReCiPe Endpoint LCA method (Humanitarian, medium weighting-H, A). The main results indicate that green hydrogen provides a 99.84% reduction in environmental impacts compared to natural gas during the operational phase, while biomethane reduces these impacts by 54.21% relative to natural gas. In the context of life cycle assessment (LCA), green hydrogen decreases fossil resource depletion by 18% and climate change-related emissions by 33.16% compared to natural gas. This study contributes to enhancing the understanding of the environmental and exergoenvironmental impacts of a double-effect vapor absorption chiller by varying the fuel usage during the operational phase.
引用
收藏
页数:28
相关论文
共 50 条
  • [1] Exergy and Exergoenvironmental Analysis of a CCHP System Based on a Parallel Flow Double-Effect Absorption Chiller
    Mousafarash, Ali
    INTERNATIONAL JOURNAL OF CHEMICAL ENGINEERING, 2016, 2016
  • [2] Parametric Analysis of a Double-effect Steam Absorption Chiller
    Ahmed, Mojahid Sid Ahmed Mohammed Salih
    Gilani, Syed Ihtsham Ul-Haq
    4TH INTERNATIONAL MEETING OF ADVANCES IN THERMOFLUIDS (IMAT 2011), PT 1 AND 2, 2012, 1440 : 870 - 879
  • [3] Exergoeconomic evaluation of a novel multigeneration process using solar driven Kalina cycle integrated with gas turbine cycle, double-effect absorption chiller, and liquefied natural gas cold energy recovery
    Yi, Sun
    Abed, Azher M.
    Deifalla, Ahmed
    Riaz, M.
    Alsenani, Theyab R.
    Elattar, Samia
    Yulei, Chun
    Al Sulaie, Saleh
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2023, 176 : 271 - 291
  • [4] Energy, exergy, exergoeconomic and exergoenvironmental analysis on a novel parallel double-effect absorption power cycle driven by the geothermal resource
    Zhang, Feng
    Yan, Yongqi
    Liao, Gaoliang
    Jiaqiang, E.
    ENERGY CONVERSION AND MANAGEMENT, 2022, 258
  • [5] Dynamic simulation of a gas-fired double-effect lithium bromide absorption chiller
    Fu, DG
    Zhen, L
    Cao, WH
    Zhang, WK
    PROCEEDINGS OF THE INTERNATIONAL SORPTION HEAT PUMP CONFERENCE, 2002, : 189 - 193
  • [6] Theoretical analysis and optimization of a double-effect series-flow-type absorption chiller
    Xu, GP
    Dai, YQ
    Tou, KW
    Tso, CP
    APPLIED THERMAL ENGINEERING, 1996, 16 (12) : 975 - 987
  • [7] Theoretical analysis and optimization of a double-effect parallel-flow-type absorption chiller
    Xu, GP
    Dai, YQ
    APPLIED THERMAL ENGINEERING, 1997, 17 (02) : 157 - 170
  • [8] Thermodynamic and Economic Performance Assessment of Double-Effect Absorption Chiller Systems with Series and Parallel Connections
    Hu, Jianke
    Teng, Kai
    Qiu, Yida
    Chen, Yuzhu
    Wang, Jun
    Lund, Peter
    ENERGIES, 2022, 15 (23)
  • [9] Exergy-based sustainability analysis of combined cycle gas turbine plant integrated with double-effect vapor absorption refrigeration system
    Ashutosh Mishra
    B. B. Arora
    Akhilesh Arora
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2024, 46
  • [10] Exergy-based sustainability analysis of combined cycle gas turbine plant integrated with double-effect vapor absorption refrigeration system
    Mishra, Ashutosh
    Arora, B. B.
    Arora, Akhilesh
    JOURNAL OF THE BRAZILIAN SOCIETY OF MECHANICAL SCIENCES AND ENGINEERING, 2024, 46 (01)