Reliability of ultrasound shear-wave elastography in assessing tensor fascia latae, gluteus medius, and iliotibial band elasticity in health individuals

被引:0
|
作者
Topaloglu, Mahir [1 ]
Turan, Zeynep [1 ]
Sarikaya, Deniz [1 ]
Taskiran, Ozden Ozyemisci [1 ]
机构
[1] Koc Univ, Istanbul, Turkiye
来源
CUKUROVA MEDICAL JOURNAL | 2024年 / 49卷 / 03期
关键词
Elastography; tissue elasticity; ultrasound; musculoskeletal; hip muscles; reliability; PAIN; HIP;
D O I
10.17826/cumj.1432600
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Gluteus medius (GMed), tensor fascia latae (TFL), and iliotibial band (ITB) play important roles in stabilizing the hip joint and are often prone to overuse syndromes such as greater trochanteric pain syndrome and runner's knee. Shear-wave elastography (SWE) presents a new avenue for rapidly assessing these structures in an outpatient setting. This study aims to assess the intra- and interobserver reliability of sWE in evaluating the GMed, TFL, and ITB. Materials and Methods: Twelve healthy volunteers (6 men and 6 women) were examined by two physiatrists using SWE. To assess inter-observer reliability, both physiatrists measured the thickness, velocity, and stiffness of GMed, TFL, and proximal and distal ITB. One physiatrist repeated the same measurements under identical conditions one week later to assess intra-observer reliability. Intra-class correlation coefficients (ICC) were calculated to evaluate reliability. Results: Inter-observer measurements showed poor reliability (ICC < 0.4) for all parameters, except for GMed thickness (ICC=0.412), which was moderately reliable. Intra-observer measurements showed varying degrees of reliability, with TFL thickness (ICC=0.733), ITBP thickness (ICC=0.592), ITBD velocity (ICC=0.634), and ITBD stiffness (ICC=0.701) demonstrating moderate reliability. However, no excellent ICC scores were observed across both intra- and inter-observer assessments. Conclusion: While SWE demonstrates promise in assessing hip stabilizers, its inconsistent reliability across different parameters highlights the need for further research. Comparative studies involving healthy and pathological groups are needed for better understanding of SWE's applicability in clinical settings.
引用
收藏
页码:632 / 638
页数:7
相关论文
共 26 条
  • [1] Reliability of shear-wave elastography in assessing thoracolumbar fascia elasticity in healthy male
    Baizhen Chen
    Hongzhou Zhao
    Linrong Liao
    Zhijie Zhang
    Chunlong Liu
    Scientific Reports, 10
  • [2] Reliability of shear-wave elastography in assessing thoracolumbar fascia elasticity in healthy male
    Chen, Baizhen
    Zhao, Hongzhou
    Liao, Linrong
    Zhang, Zhijie
    Liu, Chunlong
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [3] Reliability of ultrasound shear-wave elastography in assessing low back musculature elasticity in asymptomatic individuals
    Koppenhaver, Shane
    Kniss, Joshua
    Lilley, Daniel
    Oates, Michael
    Fernandez-de-las-Penas, Cesar
    Maher, Ruth
    Croy, Theodore
    Shinohara, Minoru
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2018, 39 : 49 - 57
  • [4] Reliability of shear-wave elastography in assessing the stiffness of the nuchal fascia and the thickness of upper cervical muscles
    Liao, Lin-Rong
    Pan, Hong-Hua
    Diao, Ying-Xiu
    Xie, Yi
    Liao, Man-Xia
    Xie, Yu-Hua
    MEDICAL ENGINEERING & PHYSICS, 2023, 120
  • [5] Reliability of shear wave elastography for the assessment of gastrocnemius fascia elasticity in healthy individual
    Zhou, Jiping
    Lin, Yuyi
    Zhang, Jiehong
    Si'tu, Xingxian
    Wang, Ji
    Pan, Weiyi
    Wang, Yulong
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [6] Reliability of shear wave elastography for the assessment of gastrocnemius fascia elasticity in healthy individual
    Jiping Zhou
    Yuyi Lin
    Jiehong Zhang
    Xingxian Si’tu
    Ji Wang
    Weiyi Pan
    Yulong Wang
    Scientific Reports, 12
  • [7] Evaluation of ultrasound point shear wave elastography reliability in an elasticity phantom
    Sultan, Salahaden R.
    Alghamdi, Amer
    Abdeen, Rawan
    Almutairi, Fahad
    ULTRASONOGRAPHY, 2022, 41 (02) : 291 - 297
  • [8] Immersion ultrasound improves the repeatability of shear-wave elastography for measuring median nerve elasticity
    Zhijun Zhang
    Hui Wang
    Xiaoya Ding
    Shu He
    Journal of Orthopaedic Surgery and Research, 18
  • [9] Immersion ultrasound improves the repeatability of shear-wave elastography for measuring median nerve elasticity
    Zhang, Zhijun
    Wang, Hui
    Ding, Xiaoya
    He, Shu
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2023, 18 (01)
  • [10] Stiffness of the iliotibial band and associated muscles in runner's knee: Assessing the effects of physiotherapy through ultrasound shear wave elastography
    Friede, Miriam C.
    Klauser, Andrea
    Fink, Christian
    Csapo, Robert
    PHYSICAL THERAPY IN SPORT, 2020, 45 : 126 - 134