Evaluating image quality on post-mortem cardiac CT using an anthropomorphic phantom

被引:0
|
作者
Molyneaux, Marissa [1 ]
Davis, Michaela [2 ]
Andersen, Thomas Rueskov [3 ]
Overgaard, Katrine Schultz [3 ]
Broersen, Alexander [4 ]
Djikstra, Jouke [4 ]
Heinsen, Laurits Juhl [3 ]
Precht, Helle [5 ,6 ,7 ,8 ,9 ]
机构
[1] Univ Coll Dublin, Sch Med, Dublin, Ireland
[2] Univ Coll Dublin, Sch Med & Med Imaging, Radiog & Diagnost Imaging, Dublin, Ireland
[3] Odense Univ Hosp, Cardiovasc Res Unit, Svendborg, Denmark
[4] Leiden Univ, Med Ctr, Dept Radiol, Leiden, Netherlands
[5] Odense Univ Hosp, Dept Radiol, Odense, Denmark
[6] Univ Southern Denmark, Dept Reg Hlth Res, Odense, Denmark
[7] Univ Hosp Southern Denmark, Lillebaelt Hosp, Dept Radiol, Kolding, Denmark
[8] UCL Univ Coll, Hlth Sci Res Ctr, Odense, Denmark
[9] Cork Univ Coll, Discipline Med Imaging & Radiat Therapy, Cork, Ireland
关键词
COMPUTED-TOMOGRAPHY ANGIOGRAPHY; DUAL-SOURCE; CORONARY; PLAQUE; HISTOPATHOLOGY; ATHEROSCLEROSIS; RECONSTRUCTION; QUANTIFICATION; VIRTOPSY;
D O I
10.1016/j.jmir.2025.101876
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: Ischemic heart disease is a major cause of mortality worldwide. Coronary computed tomography angiography (CCTA) has been recognised as a procedure for diagnosing atherosclerotic plaques. One method used to test the diagnostic accuracy of new technical developments on the CT scanner is post-mortem imaging. This study aimed to compare image quality of CCTA on post-mortem hearts scanned inside an anthropomorphic phantom versus scanning directly on the scanner bed, and evaluate which image was most comparable to scanning in-vivo (living patients). Methods: Ten post-mortem hearts were scanned using the two methods and ten CCTA in-vivo were included for comparison. Region of interest (ROI) measurements in both the right and left ventricles of the hearts were made and coronary vessel analysis measured plaque burden and composition. To examine the difference between each scanning method, we compared the mean and standard deviation of these measurements. The difference in image quality was also examined visually through images and a dot plot. Results: A Wilcoxon Signed Rank test showed that ROI measurements from the two methods were significantly different. Mann- Whitney-U tests showed a significant difference between the in-vivo measurements and the two post-mortem scanning methods. Wilcoxon signed-rank tests indicated a significant difference for 4 out of 5 plaque measurements. Visually, a noisier image was seen using the phantom, though it was closer to in-vivo imaging and had a clearer plaque visualisation. Conclusion: A significant difference in image quality between scans taken with the heart directly on the scanner bed compared to inside the phantom, with those inside the phantom being more comparable to in-vivo scans. This highlights the importance of using an appropriate scanning technique when imaging post-mortem organs.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Post-mortem CT in the investigation of homicides
    Kranioti, E. F.
    Spanakis, K.
    Flouri, D. E.
    Klontzas, M. E.
    Karantanas, A. H.
    CLINICAL RADIOLOGY, 2023, 78 (11) : 832 - 838
  • [2] Forensic post-mortem CT in children
    Edwards, H.
    Shelmerdine, S. C.
    Arthurs, O. J.
    CLINICAL RADIOLOGY, 2023, 78 (11) : 839 - 847
  • [3] Detection of aortic rupture using post-mortem computed tomography and post-mortem computed tomography angiography by cardiac puncture
    Zhou, Shu
    Wan, Lei
    Shao, Yu
    Ying, Chongliang
    Wang, Yahui
    Zou, Donghua
    Xia, Wentao
    Chen, Yijiu
    INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 2016, 130 (02) : 469 - 474
  • [4] Detection of aortic rupture using post-mortem computed tomography and post-mortem computed tomography angiography by cardiac puncture
    Shu Zhou
    Lei Wan
    Yu Shao
    Chongliang Ying
    Yahui Wang
    Donghua Zou
    Wentao Xia
    Yijiu Chen
    International Journal of Legal Medicine, 2016, 130 : 469 - 474
  • [5] Post-mortem CT examination - own experiences
    Urbanik, Andrzej
    Chrzan, Robert
    Wozniak, Krzysztof
    Moskala, Artur
    POLISH JOURNAL OF RADIOLOGY, 2009, 74 (04) : 55 - 63
  • [6] Advances in post-mortem CT-angiography
    Grabherr, S.
    Grimm, J.
    Dominguez, A.
    Vanhaebost, J.
    Mangin, P.
    BRITISH JOURNAL OF RADIOLOGY, 2014, 87 (1036):
  • [7] Imaging findings of diabetes on post-mortem CT
    Ruder, Thomas D.
    Schweitzer, Wolf
    Ampanozi, Garyfalia
    Gascho, Dominic
    Flach, Patricia M.
    Thali, Michael J.
    Hatch, Gary M.
    JOURNAL OF FORENSIC RADIOLOGY AND IMAGING, 2018, 13 : 27 - 41
  • [8] Pitfalls in post-mortem CT-angiography - Intravascular contrast induces post-mortem pericardial effusion
    Grabherr, Silke
    Wittig, Holger
    Dedouit, Fabrice
    Wozniak, Krzysztof
    Vogel, Hermann
    Heinemann, Axel
    Fischer, Florian
    Moskala, Artur
    Guglielmi, Guiseppe
    Mangin, Patrice
    Grimm, Jochen
    LEGAL MEDICINE, 2015, 17 (03) : 218 - 219
  • [9] Pitfalls in post-mortem CT-angiography - intravascular contrast induces post-mortem pericardial effusion
    Berger, Nicole
    Martinez, Rosita
    Winklhofer, Sebastian
    Flach, Patricia M.
    Ross, Steffen
    Ampanozi, Garyfalia
    Gascho, Dominic
    Thali, Michael J.
    Ruder, Thomas D.
    LEGAL MEDICINE, 2013, 15 (06) : 315 - 317
  • [10] Micro-CT yields high image quality in human fetal post-mortem imaging despite maceration
    Ian Craig Simcock
    Susan Cheng Shelmerdine
    Dean Langan
    Guy Anna
    Neil James Sebire
    Owen John Arthurs
    BMC Medical Imaging, 21