Abdominal aortic aneurysm classification based on dynamic intraluminal thrombus analysis during cardiac cycle

被引:0
|
作者
Guest, Alice [1 ,2 ]
Forneris, Arianna [2 ]
Satriano, Alessandro [2 ]
Moore, Randy D. [2 ,3 ,4 ]
Di Martino, Elena S. [1 ,2 ,4 ]
机构
[1] Univ Calgary, Dept Biomed Engn, Calgary, AB, Canada
[2] ViTAA Med Solut Inc, Montreal, PQ, Canada
[3] Univ Calgary, Div Vasc Surg, Calgary, AB, Canada
[4] Univ Calgary, Libin Cardiovasc Inst Alberta, Calgary, AB, Canada
关键词
Abdominal aortic aneurysm; Aneurysm rupture; Intraluminal thrombus; Multiphase imaging; BEHAVIOR;
D O I
10.1016/j.jvscit.2025.101736
中图分类号
R61 [外科手术学];
学科分类号
摘要
The major complication of abdominal aortic aneurysm (AAA) is sudden rupture with an associated high mortality rate. The only clinical classifier for the risk of AAA rupture is the size of the aneurysm or its maximum diameter. We reviewed the role of intraluminal thrombus (ILT) by investigating the motion of both the lumen and wall surfaces of ILT throughout the cardiac cycle. We hypothesize that the response of the thrombus to the cyclic blood pressure provides insight into the state of the thrombus and its propensity to rupture, akin to what could be obtained from a mechanical compression test. Patients were selected from two studies: patients who underwent surgical intervention and patients from a retrospective study of AAA growth. Patients were selected to provide a wide range of AAA behaviors leading to a disease progression. Multiphase computed tomographic images of 14 patients were obtained from Peter Lougheed Hospital in Calgary, Canada. The geometries of the aortic wall and lumen were segmented from the images, and thrombus volume was determined at ten evenly spaced phases of the cardiac cycle. Where possible, the results were matched to known ex vivo mechanical properties, growth, and clinical outcomes for each AAA. The relative changes of wall, lumen, and thrombus volumes throughout the cardiac cycle classified AAAs into four types: (1) type I, aneurysms with a minimal wall movement, negative lumen expansion, and positive ILT expansion, (2) type II, aneurysms whose lumen undergoes small expansion, while the expansion is accommodated by the ILT and wall, (3) type III, a transition type characterized by lumen, wall, and thrombus expansions, and (4) type IV, characterized by lumen expansion matching or exceeding wall expansion, while the thrombus exhibits very small or negative deformation. This last behavior leads to an over-pressurized thrombus, which could enable the formation of permeable channels, often observable in medical images obtained in patients experiencing aneurysm rupture. By providing insight into thrombus behavior and the likelihood of channel development in the thrombus, AAA classification can improve the assessment of clinical risk for aneurysms: type I is associated with a stiff aneurysm wall that resists thrombus deformation and may be related to the risk of dissection, type II and type III are transition types, and type IV is associated with the formation of permeable channels and thrombus cracks which may indicate possible risk of rupture. (J Vasc Surg Cases Innov Tech 2025:11:101736.)
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Intraluminal Thrombus and Abdominal Aortic Aneurysm Complications
    Manenti, Antonio
    Farinetti, Alberto
    Manco, Gianrocco
    Mattioli, Anna Vittoria
    ANNALS OF VASCULAR SURGERY, 2022, 83 : E8 - E9
  • [2] Intraluminal thrombus in abdominal aortic aneurysm: a friend or a foe?
    Simka, Marian
    Hobot, Jacek
    Skula, Marcin
    INTERNATIONAL ANGIOLOGY, 2019, 38 (06) : 508 - 509
  • [3] Innocent bystander? Intraluminal thrombus in abdominal aortic aneurysm
    Yoshimura, Koichi
    Ikeda, Yasuhiro
    Aoki, Hiroki
    ATHEROSCLEROSIS, 2011, 218 (02) : 285 - 286
  • [4] Intraluminal thrombus predicts rupture of an abdominal aortic aneurysm
    Satta, J
    Laara, E
    Juvonen, T
    JOURNAL OF VASCULAR SURGERY, 1996, 23 (04) : 737 - 739
  • [5] Intraluminal thrombus is associated with early rupture of abdominal aortic aneurysm
    Haller, Stephen J.
    Crawford, Jeffrey D.
    Courchaine, Katherine M.
    Bohannan, Colin J.
    Landry, Gregory J.
    Moneta, Gregory L.
    Azarbal, Amir F.
    Rugonyi, Sandra
    JOURNAL OF VASCULAR SURGERY, 2018, 67 (04) : 1051 - +
  • [6] Effect of intraluminal thrombus on pressure transmission in the abdominal aortic aneurysm
    Hinnen, JW
    Koning, OHJ
    Visser, MJT
    Van Bockel, HJ
    JOURNAL OF VASCULAR SURGERY, 2005, 42 (06) : 1176 - 1182
  • [7] Architecture of intraluminal thrombus removed from abdominal aortic aneurysm
    Matusik, Pawel
    Mazur, Piotr
    Stepien, Ewa
    Pfitzner, Roman
    Sadowski, Jerzy
    Undas, Anetta
    JOURNAL OF THROMBOSIS AND THROMBOLYSIS, 2010, 30 (01) : 7 - 9
  • [8] Abdominal aortic aneurysm, arterial stiffening and the role of the intraluminal thrombus
    Hansen, Maria Lyck
    Thomsen, Marie Dahl
    Rasmussen, Lars Melholt
    Lindholt, Jes S.
    VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE, 2015, 44 (05) : 349 - 353
  • [9] Effect of intraluminal thrombus on abdominal aortic aneurysm wall stress
    Mower, WR
    Quinones, WJ
    Gambhir, SS
    JOURNAL OF VASCULAR SURGERY, 1997, 26 (04) : 602 - 608
  • [10] Architecture of intraluminal thrombus removed from abdominal aortic aneurysm
    Paweł Matusik
    Piotr Mazur
    Ewa Stępień
    Roman Pfitzner
    Jerzy Sadowski
    Anetta Undas
    Journal of Thrombosis and Thrombolysis, 2010, 30 : 7 - 9