Speech Perception Outcomes with the Anatomy-Based Fitting Map among Experienced, Adult Cochlear Implant Users: A Longitudinal Study

被引:0
|
作者
Wangchuk, Pelden [1 ,2 ]
Umat, Cila [1 ]
Chong, Foong Yen [1 ]
Zaki, Faizah Mohd [3 ]
Abdullah, Asma [4 ]
机构
[1] Univ Kebangsaan Malaysia, Fac Hlth Sci, Ctr Rehabil & Special Needs Studies, Kuala Lumpur, Malaysia
[2] JDWNR Hosp, Dept Otorhinolaryngol, Audiol Unit, MoH, Thimphu, Bhutan
[3] UNIV KEBANGSAAN MALAYSIA, Fac Med, Dept Radiol, KUALA LUMPUR, Malaysia
[4] Univ Kebangsaan Malaysia, Fac Med, Dept Otorhinolaryngol Head & Neck Surg, Kuala Lumpur, Malaysia
关键词
Cochlear implant; Vowel and consonant perception; Anatomy-based fitting; Frequency-to-place mismatch; Cochlear implant programming; FREQUENCY; RECOGNITION;
D O I
10.1159/000540965
中图分类号
R36 [病理学]; R76 [耳鼻咽喉科学];
学科分类号
100104 ; 100213 ;
摘要
Introduction: Anatomy-based fitting (ABF), a relatively new technique for cochlear implant (CI) programming, attempts to lessen the impact of the electrode insertion location-related frequency-to-place mismatch (FPM). This study aimed to compare vowels and consonant perception in quiet and in noise among experienced adult CI users using the ABF and the regular, conventional-based fitting (CBF) map (pre-ABF) over 6 months. Methods: Nine ears from eight experienced adult CI users were included in the experimental and longitudinal research. Using surgical planning software called Otoplan, postoperative computed computed tomography scans were used to determine the locations of intracochlear electrodes and their angle of insertion. The anatomy-based frequency bands were produced by Maestro 9.0 CI fitting software using the Otoplan data. Nonsense syllables with consonant-vowel-consonant (CVC) recognition scores in quiet and noise (+5 dB SNR) were compared at baseline, 3, and 6 months after ABF. The vowels involved were /a, i, u/, while the consonants were voiced /b, d, g/ and voiceless /p, t, k/ plosives. Speech pieces were presented at 30 dB SL in a sound-treated room through a loudspeaker positioned at 0 degrees azimuth. Results: On average, the ABF maps shifted center frequency ranging from 0.46 semitones (0.04 octave) at (E12) to 23.94 semitones (1.99 octave) at (E1) as compared to the CBF maps. The mean vowel and consonant identification scores in quiet and in noise were significantly higher in ABF than in CBF (p < 0.05) with a large effect size and the trend of improvement was seen with time. Voiced consonants had better scores than the voiceless consonants. Conclusion: The results demonstrated improved perception of vowels and consonants, particularly for sounds containing voicing cues after using the ABF maps. The results also suggested that ABF could be more effective for voice detection in noise. Overall, the findings indicate that correcting place mismatch with an ABF map may improve speech perception, at least among experienced adult CI users. (c) 2024 S. Karger AG, Basel
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Can anatomy-based fitting improve musical perception in adult cochlear implant users?
    Lassaletta, Luis
    Calvino, Miryam
    Sanchez-Cuadrado, Isabel
    Munoz, Elena
    Gavilan, Javier
    BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY, 2025, 91 (02)
  • [2] One Click Is Not Enough: Anatomy-Based Fitting in Experienced Cochlear Implant Users
    Kurz, Anja
    Mueller-Graff, Franz-Tassilo
    Hagen, Rudolf
    Rak, Kristen
    OTOLOGY & NEUROTOLOGY, 2022, 43 (10) : 1176 - 1180
  • [3] Anatomy-based fitting improves speech perception in noise for cochlear implant recipients with single-sided deafness
    Kurz, Anja
    Herrmann, David
    Mueller-Graff, Franz-Tassilo
    Voelker, Johannes
    Hackenberg, Stephan
    Rak, Kristen
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2025, 282 (01) : 467 - 479
  • [4] Using Anatomy-Based Fitting to Reduce Frequency-to-Place Mismatch in Experienced Bilateral Cochlear Implant Users: A Promising Concept
    Kurz, Anja
    Herrmann, David
    Hagen, Rudolf
    Rak, Kristen
    JOURNAL OF PERSONALIZED MEDICINE, 2023, 13 (07):
  • [5] Electrophysiological and speech perception measures of auditory processing in experienced adult cochlear implant users
    Kelly, AS
    Purdy, SC
    Thorne, PR
    CLINICAL NEUROPHYSIOLOGY, 2005, 116 (06) : 1235 - 1246
  • [6] Intra-Cochlear Current Spread Correlates with Speech Perception in Experienced Adult Cochlear Implant Users
    Joly, Charles-Alexandre
    Reynard, Pierre
    Hermann, Ruben
    Seldran, Fabien
    Gallego, Stephane
    Idriss, Samar
    Thai-Van, Hung
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (24)
  • [7] Longitudinal Infant Speech Perception in Young Cochlear Implant Users
    Uhler, Kristin
    Yoshinaga-Itano, Christie
    Gabbard, Sandra Abbott
    Rothpletz, Ann M.
    Jenkins, Herman
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2011, 22 (03) : 129 - 142
  • [8] Experienced Adult Cochlear Implant Users Show Improved Speech Recognition When Target Fitting Parameters Are Applied
    de Quillettes, Richard
    Kaandorp, Marre
    Merkus, Paul
    Kramer, Sophia E.
    Smits, Cas
    EAR AND HEARING, 2024, 45 (05): : 1264 - 1273
  • [9] A Longitudinal Study of Speech Perception Skills and Device Characteristics of Adolescent Cochlear Implant Users
    Robinson, Elizabeth J.
    Davidson, Lisa S.
    Uchanski, Rosalie M.
    Brenner, Christine M.
    Geers, Ann E.
    JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY, 2012, 23 (05) : 341 - 349
  • [10] Advancing Cochlear Implant Programming: X-ray Guided Anatomy-Based Fitting
    Alahmadi, Asma
    Abdelsamad, Yassin
    Thabet, Elsaeid M.
    Hafez, Ahmed
    Alghamdi, Fares
    Badr, Khalid M.
    Alghamdi, Saeed
    Hagr, Abdulrahman
    OTOLOGY & NEUROTOLOGY, 2024, 45 (02) : 107 - 113