Distal Transradial Access Optimization: A Prospective Trial of Ultrasound-Guided Radial Artery Characterization for the Anatomical Snuffbox

被引:0
|
作者
Kozinski, Lukasz [1 ]
Orzalkiewicz, Zbigniew [1 ]
Zagozdzon, Pawel [2 ]
Dabrowska-Kugacka, Alicja [3 ]
机构
[1] Chojnice Specialist Hosp, Dept Cardiol, Lesna 10, PL-89600 Chojnice, Poland
[2] Med Univ Gdansk, Dept Hyg & Epidemiol, Debinki 7, PL-80211 Gdansk, Poland
[3] Med Univ Gdansk, Dept Cardiol & Electrotherapy, Smoluchowskiego 17, PL-80214 Gdansk, Poland
关键词
distal transradial access; snuffbox approach; distal radial artery; radial artery; vascular ultrasound; radial ultrasound; radial artery pulse; PERCUTANEOUS CORONARY; INTERVENTION; METAANALYSIS; DIAMETER;
D O I
10.3390/diagnostics14182081
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Objectives: The distal transradial approach (dTRA) is increasingly used in interventional cardiology. Doppler Ultrasound (DUS) effectively assesses radial artery (RA) characteristics. This study aims to identify specific RA DUS characteristics in patients undergoing coronary procedures via dTRA. Methods: Participants from the ANTARES trial who completed the intervention per-protocol and retained RA patency were included. DUS was performed at baseline, 1 day, and 60 days post-procedure. Results: Among 400 participants, 348 had either dTRA (n = 169) or conventional transradial access (cTRA) (n = 179). Distal RA lumen diameter was 12% smaller than that of the proximal RA (p < 0.001). Men had a 14% larger distal RA diameter than women (2.33 +/- 0.31 mm vs. 2.04 +/- 0.27 mm, p < 0.0001), similar to the proximal RA relationship. Peak flow velocities were similar between the sexes. Univariate linear regression showed that height, weight, body mass index, and body surface area (BSA) predicted arterial size, with BSA remaining significant in multivariate analysis (beta coefficient 0.62; confidence interval 0.49-0.75; p < 0.0001). Distal RA diameter correlated positively with palpable pulse at the snuffbox and wrist. The dTRA resulted in an immediate 14% and 11% increase in distal and proximal RA diameter, respectively (both p < 0.05). Sixty days after dTRA, the distal RA remained slightly dilated (p < 0.05), while the proximal RA returned to baseline. Conclusions: Distal RA diameter is significantly associated with sex, measuring smaller than the forearm segment. A strong palpable pulse correlates with larger distal RA size. The dTRA induces RA lumen expansion. A thorough understanding of distal RA anatomy is essential for optimizing patient selection and refining techniques for transradial procedures.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Ultrasound-Guided Distal Transradial Access in the Anatomical Snuffbox in Coronary Angiography and Intervention
    Lee, Sang Yeub
    Kim, Min
    Kim, Sang Min
    Bae, Jang-Whan
    Hwang, Kyung-Kuk
    Cho, Myeong-Chan
    JACC-CARDIOVASCULAR INTERVENTIONS, 2019, 12 (04) : S22 - S22
  • [2] Ultrasound-guided access to the distal radial artery at the anatomical snuffbox for catheter-based vascular interventions: a technical guide
    Hadjivassiliou, Anastasia
    Kiemeneij, Ferdinand
    Nathan, Sandeep
    Klass, Darren
    EUROINTERVENTION, 2021, 16 (16) : 1342 - 1348
  • [3] Recanalization of the occluded radial artery via distal transradial access in the anatomic snuffbox
    Feng Li
    Gan-Wei Shi
    Bi-Feng Zhang
    Xiao-Long Yu
    Hao-Min Huang
    Jian-Qiang Xiao
    Gao-Jun Cai
    BMC Cardiovascular Disorders, 21
  • [4] Recanalization of the occluded radial artery via distal transradial access in the anatomic snuffbox
    Li, Feng
    Shi, Gan-Wei
    Zhang, Bi-Feng
    Yu, Xiao-Long
    Huang, Hao-Min
    Xiao, Jian-Qiang
    Cai, Gao-Jun
    BMC CARDIOVASCULAR DISORDERS, 2021, 21 (01)
  • [5] Optical Coherent Tomographic Assessment of Radial Artery After Transradial Coronary Intervention Via Distal Radial Access at Anatomical Snuffbox
    Lee, Sang Yeub
    Bae, Jang-Whan
    JACC-CARDIOVASCULAR INTERVENTIONS, 2020, 13 (04) : S35 - S35
  • [6] Distal Radial Artery Access in the Anatomical Snuffbox for Neurointerventions: Case Report
    McCarthy, David J.
    Chen, Stephanie H.
    Brunet, Marie-Christine
    Shah, Sumedh
    Peterson, Eric
    Starke, Robert M.
    WORLD NEUROSURGERY, 2019, 122 : 355 - 359
  • [7] Pseudoaneurysm: a rare complication of distal transradial access in the anatomical snuffbox
    Boumezrag, Maryam
    Ummat, Bianca
    Reiner, Jonathan
    Venbrux, Anthony
    Sarin, Shawn
    CVIR ENDOVASCULAR, 2019, 2 (01)
  • [8] Safety of ultrasound-guided distal radial artery access for abdominopelvic transarterial interventions: a prospective study
    Koury, Adib, Jr.
    Monsignore, Lucas Moretti
    de Castro-Afonso, Luis Henrique
    Abud, Daniel Giansante
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2020, 26 (06) : 570 - 574
  • [9] Pseudoaneurysm: a rare complication of distal transradial access in the anatomical snuffbox
    Maryam Boumezrag
    Bianca Ummat
    Jonathan Reiner
    Anthony Venbrux
    Shawn Sarin
    CVIR Endovascular, 2
  • [10] Distal transradial access in the anatomical snuffbox for diagnostic cerebral angiography
    Brunet, Marie-Christine
    Chen, Stephanie H.
    Sur, Samir
    McCarthy, David J.
    Snelling, Brian
    Yavagal, Dileep R.
    Starke, Robert M.
    Peterson, Eric C.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2019, 11 (07) : 710 - +