Development of high-speed scanning acoustic microscopy system: Simplified design and stabilization

被引:0
|
作者
Kim, Donghyeok [1 ]
Oh, Hanmin [1 ]
Choi, Jaeyeop [2 ,4 ]
Vo, Tan Hung [2 ]
Vu, Dinh Dat [1 ]
Mondal, Sudip [3 ]
Pham, Van Hiep [6 ,7 ]
Lee, Byeong-il [1 ,3 ,5 ]
Oh, Junghwan [1 ,2 ,3 ,4 ]
机构
[1] Pukyong Natl Univ, Dept Biomed Engn, Ind Convergence Bion Engn 4 0, Busan 48513, South Korea
[2] Pukyong Natl Univ, Smart Gym Based Translat Res Ctr Act Sr Healthcare, Busan 48513, South Korea
[3] Pukyong Natl Univ, Digital Healthcare Res Ctr, Busan 48513, South Korea
[4] Ohlabs Corp, Busan 48513, South Korea
[5] Pukyong Natl Univ, Dept Smart Healthcare, Busan 48513, South Korea
[6] PHENIKAA Univ, Fac Mech Engn & Mechatron, Hanoi 12116, Vietnam
[7] A&A Green Phoenix Grp JSC, PHENIKAA Res & Technol Inst PRATI, 167 Hoang Ngan, Hanoi 11313, Vietnam
基金
新加坡国家研究基金会;
关键词
Scanning Acoustic Microscopy; High-speed SAM system; Vibration; Stabilization; Product quality evaluation; INSPECTION;
D O I
10.1016/j.jestch.2024.101911
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Scanning acoustic microscopy (SAM) is a useful tool for nondestructive inspection and provides inner structural information or defects that can adversely affect the product quality. Several SAM systems have been developed for application in various fields. Conventional SAM systems operate with a limited scanning range or long scanning time, which can cause inefficient economic and labor gains. Numerous studies have been conducted to reduce the scanning time, but these are too complicated or consume a large amount of time. In this study, a simple high-speed SAM system that provides high-quality images with high resolution within a short period of time is proposed. The scanning module is based on a single slider-crank and ball-screw mechanism to provide fast movement and low-cost development. When the system is operated at a high speed, the vibrations have a negative effect on the image quality. A stabilization process was applied to obtain high-quality images. Based on stress analysis, the main parts of the scanning module were optimized, and the counterweight was designed by applying simple mathematical modelling. To verify these vibration-reduction solutions, several samples were scanned using the developed high-speed SAM system. The obtained images successfully provided useful internal information and demonstrated the performance of the developed high-speed SAM system. Compared to other conventional SAM systems, the high-speed SAM system reduces the scanning time by approximately 77.2% with an acceptable scanning range, which shows its powerful application potential in various fields.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Design of the stabilization control system of a high-speed craft
    Giallanza, Antonio
    Cannizzaro, Luigi
    Porretto, Mario
    Marannano, Giuseppe
    ADVANCES ON MECHANICS, DESIGN ENGINEERING AND MANUFACTURING, 2017, : 575 - 584
  • [2] A Z-scanner Design for High-Speed Scanning Probe Microscopy
    Yong, Yuen Kuan
    Mohemani, S. O. Reza
    2012 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2012, : 4780 - 4785
  • [3] High-Speed Scanning Probe Microscopy in Biomedicine
    A. I. Akhmetova
    V. M. Gukasov
    Y. L. Rybakov
    I. V. Yaminsky
    Biomedical Engineering, 2021, 54 : 434 - 437
  • [4] High-Speed Scanning Probe Microscopy in Biomedicine
    Akhmetova, A., I
    Gukasov, V. M.
    Rybakov, Y. L.
    Yaminsky, I., V
    BIOMEDICAL ENGINEERING-MEDITSINSKAYA TEKNIKA, 2021, 54 (06): : 434 - 437
  • [5] Design and development of a high-speed data acquisition system for acquiring acoustic emission signals
    Saha, Sucharitha
    Mallisetty, Phani Kumar
    Sen, Siddheswar
    Giri, S. K.
    MATERIALS TODAY-PROCEEDINGS, 2022, 66 : 3830 - 3837
  • [6] Research and Development of High-speed Laser Scanning Galvanometer System
    Ho, Chao-Ching
    Liang, Yi-Shan
    SMART SCIENCE, 2013, 1 (02): : 82 - 85
  • [7] Development of Acoustic Emission High-speed Data Acquisition System
    Ting, You
    Li Pei-jiang
    Tong Guan-jun
    Shen Jian-wei
    MATERIALS SCIENCE AND INFORMATION TECHNOLOGY, PTS 1-8, 2012, 433-440 : 5666 - +
  • [8] High-speed, two-photon scanning microscopy
    Kim, KH
    Buehler, C
    So, PTC
    BIOPHYSICAL JOURNAL, 1999, 76 (01) : A99 - A99
  • [9] Development of a High-frequency Ultrasound System for High-speed Image Scanning
    WU Jian-xing
    CHEN Pei-zhan
    WANG Jian-lin
    CHEN Guan-chun
    CHEN Tai-song
    Chinese Journal of Biomedical Engineering, 2013, 22 (02) : 79 - 85
  • [10] Development of high-speed ion conductance microscopy
    Watanabe, Shinji
    Kitazawa, Satoko
    Sun, Linhao
    Kodera, Noriyuki
    Ando, Toshio
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2019, 90 (12):