Respiratory rate estimation from photoplethysmogram baseline wandering by harmonic analysis and sequential fusion

被引:0
|
作者
Zhang, Chi [1 ]
Wei, Shaoming [2 ]
Dong, Ge [1 ]
Zeng, Yajun [2 ]
Zhu, Guohun [3 ]
Zhou, Xujuan [4 ]
Liu, Feng [3 ]
机构
[1] Tsinghua Univ, Sch Aerosp Engn, Beijing, Peoples R China
[2] Beihang Univ, Sch Elect & Informat Engn, Beijing, Peoples R China
[3] Univ Queensland, Sch Informat Technol & Elect Engn, St Lucia, Qld, Australia
[4] Univ Southern Queensland, Sch Business, Toowoomba, Qld, Australia
基金
中国国家自然科学基金;
关键词
Frequency domain analysis; Harmonics; Photoplethysmogram; Respiratory rate; Sequential fusion; BREATHING RATE; HEART; ELECTROCARDIOGRAM;
D O I
10.1016/j.bspc.2024.107006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Photoplethysmogram (PPG) is typically employed to monitor heart rate and estimate respiratory rate (RR). The majority of PPG-based respiratory rate estimation methods necessitate the identification of individual heartbeat peaks or the decomposition of PPG signals, which is laborious and exhibits restricted performance. This paper presents a novel method for estimating respiratory rate, which employs frequency-domain analysis and sequential fusion over time. The proposed method exploits the harmonics of the PPG baseline wandering induced by respiration, seeking the respiratory frequency that maximizes the signal harmonic power. A sequential fusion between signal windows is designed to regularize the results and suppress possible significant errors while evaluating the quality of each fused output. The algorithm is verified using PPG signals from the CapnoBase and BIDMC datasets and yielded mean absolute errors (MAE) of 0.1 and 2.0 breaths per minute for each dataset, respectively, when providing respiratory rate estimates for all windows. Furthermore, the accuracy of the method can be improved by the exclusion of low-quality windows based on the proposed sequential assessment of quality. The application of harmonic analysis and sequential fusion techniques represents a novel approach for estimating respiratory rate from PPG with enhanced performance. The MATLAB code for the processing of the two datasets is accessible via the following link: https://github.com/Chi1988723/PPG-respiratory-rate-estim ation.git.
引用
收藏
页数:11
相关论文
共 50 条
  • [1] Bayesian Fusion of Algorithms for the Robust Estimation of Respiratory Rate from the Photoplethysmogram
    Zhu, Tingting
    Pimentel, Marco A. F.
    Clifford, Gari D.
    Clifton, David A.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 6138 - 6141
  • [2] Multiparameter Respiratory Rate Estimation From the Photoplethysmogram
    Karlen, Walter
    Raman, Srinivas
    Ansermino, J. Mark
    Dumont, Guy A.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2013, 60 (07) : 1946 - 1953
  • [3] Robust Estimation of Respiratory Rate from Photoplethysmogram with Respiration Quality Analysis
    Sultan, Muhammad Ahmad
    Saadeh, Wala
    2022 IEEE INTERNATIONAL SYMPOSIUM ON CIRCUITS AND SYSTEMS (ISCAS 22), 2022, : 65 - 69
  • [4] Recording system and data fusion algorithm for enhancing the estimation of the respiratory rate from photoplethysmogram
    Cernat, Roxana A.
    Ciorecan, Silvia I.
    Ungureanu, Constantin
    Arends, Johan
    Strungaru, Rodica
    Ungureanu, G. Mihaela
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 5977 - 5980
  • [5] Respiratory rate estimation from the photoplethysmogram via joint sparse signal reconstruction and spectra fusion
    Zhang, Xiaorong
    Ding, Quan
    BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2017, 35 : 1 - 7
  • [6] Empirical Mode Decomposition for Respiratory and Heart Rate Estimation from the Photoplethysmogram
    Garde, A.
    Karlen, W.
    Dehkordi, P.
    Ansermino, J. M.
    Dumont, G. A.
    2013 COMPUTING IN CARDIOLOGY CONFERENCE (CINC), 2013, 40 : 799 - 802
  • [7] A Mother Wavelet Selection Algorithm for Respiratory Rate Estimation from Photoplethysmogram
    Dan, Guo
    Li, Zhijian
    Ding, Huijung
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 962 - 965
  • [8] Estimation of Respiratory Rate From Photoplethysmogram Data Using Time-Frequency Spectral Estimation
    Chon, Ki H.
    Dash, Shishir
    Ju, Kihwan
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (08) : 2054 - 2063
  • [9] Respiratory Rate Estimation Using the Photoplethysmogram: Towards the Implementation in Wearables
    Kozumplik, Jiri
    Smital, Lukas
    Nemcova, Andrea
    Ronzhina, Marina
    Smisek, Radovan
    Marsanova, Lucie
    Kralik, Martin
    Vitek, Martin
    2021 COMPUTING IN CARDIOLOGY (CINC), 2021,
  • [10] Estimating Instantaneous Respiratory Rate from the Photoplethysmogram
    Dehkordi, Parastoo
    Garde, Ainara
    Molavi, Behnam
    Petersen, Christian L.
    Ansermino, J. Mark
    Dumont, Guy A.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 6150 - 6153