Effect of fabrication methods and number of supporting teeth on the surface accuracy and dimensional stability of implant surgical guides

被引:0
|
作者
Wu, Jiacheng [1 ]
Shui, Yusen [2 ]
Xie, Chenyang [1 ,2 ]
Wu, Qin [2 ]
Yu, Meiqi [1 ]
Luo, Tian [2 ]
Zhao, Yuwei [2 ]
Yu, Haiyang [3 ]
机构
[1] Sichuan Univ, West China Hosp Stomatol, Natl Ctr Stomatol, Dept Dent Technol,State Key Lab Oral Dis,Natl Clin, Chengdu, Peoples R China
[2] Sichuan Univ, Natl Clin Res Ctr Oral Dis, Natl Ctr Stomatol, Dept Prosthodont,West China Sch Stomatol,State Key, Chengdu, Peoples R China
[3] Sichuan Univ, West China Hosp Stomatol, Natl Ctr Stomatol, Natl Clin Res Ctr Oral Dis,State Key Lab Oral Dis, Chengdu, Peoples R China
来源
JOURNAL OF PROSTHETIC DENTISTRY | 2025年 / 133卷 / 02期
关键词
SURGERY;
D O I
10.1016/j.prosdent.2024.10.031
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Implant surgical guides manufactured using different fabrication methods have been commonly used for computer-guided implant placement. However, how fabrication methods and the number of supporting teeth influence accuracy and stability remains uncertain. Purpose. The purpose of this in vitro study was to evaluate the influence of fabrication methods and number of supporting teeth on the surface accuracy and dimensional stability of implant surgical guides with 3 different 3-dimensional (3D) printers and 1 computer numeric controlled (CNC) milling machine. Material and methods. Two tooth-supported maxillary implant surgical guides with different number of supporting teeth (S: short span with 4 supporting teeth, L: long span with complete arch supporting) were used to fabricate the specimens. Eighty surgical guides were fabricated from 3 different 3D printers and 1 milling machine as follows: group SLA-S (n=10) and SLA-L (n=10) were fabricated with a desktop stereolithography (SLA) 3D printer and photopolymerizing resin; group PolyJet-S (n=10) and PolyJet-L (n=10) were fabricated with a PolyJet 3D printer and photopolymerizing resins; group DLP-S (n=10) and DLP-L (n=10) were fabricated with a desktop digital light processing (DLP) 3D printer and photopolymerizing resin; and group MILL-S (n=10) and group MILL-L (n=10) were fabricated with a 5-axis milling machine and polymethyl methacrylate (PMMA) blanks. All surgical guides were digitized immediately after postprocessing and after 1, 2, and 3 months using a desktop scanner. The congruency between design files and digitized files was quantified with the root mean square (RMS) error with a metrology program (Geomagic Control X). Two-way ANOVA was used to analyze trueness, and the Levene test was used to assess precision (alpha=.05). Results. The fabrication methods and number of supporting teeth significantly affected the surface trueness of the guide (P<.001). Milled guides had the lowest mean RMS value for surface trueness, 45 <mu>m for guides with 4 supporting teeth and 59 mu m for guides with complete arch supporting. Regarding precision, the Levene test revealed significant difference among fabrication methods (P<.05), while no significant difference was found in the same fabrication method group (P>.05). After 3 months of storage, RMS values increased significantly in the complete arch supporting group comparison of SLA, PolyJet, and DLP (P<.001, P<.001, and P=.015, respectively). RMS values remained similar in other groups. Conclusions. The trueness and dimensional stability of the surface of the implant surgical guides were affected by fabrication methods and the number of supporting teeth. However, the precision was only affected by fabrication methods. Milled surgical guides showed higher accuracy and better dimensional stability after storage than those produced with 3D printers. Among the groups of 3D printing, guides with 4 supporting teeth showed higher trueness and a lower degree of deformation after storage.
引用
收藏
页码:530e1 / 530e9
页数:9
相关论文
共 16 条
  • [1] Effect of Fabrication Technology on the Accuracy of Surgical Guides for Dental-Implant Surgery
    Lo Russo, Lucio
    Guida, Laura
    Mariani, Pierluigi
    Ronsivalle, Vincenzo
    Gallo, Crescenzio
    Cicciu, Marco
    Laino, Luigi
    BIOENGINEERING-BASEL, 2023, 10 (07):
  • [2] Three Dimensional Printed Surgical Guides: Effect of Time on Dimensional Stability
    Lo Russo, Lucio
    Guida, Laura
    Zhurakivska, Khrystyna
    Troiano, Giuseppe
    Di Gioia, Claudio
    Ercoli, Carlo
    Laino, Luigi
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2023, 32 (05): : 431 - 438
  • [3] Influence of supporting teeth quantity of surgical guide on the accuracy of the immediate implant in the maxillary central incisor: an in vitro study
    Nguyen, Meo
    Nguyen, Huynh Kim Khanh
    Nguyen, Thien Nga
    Huynh, Nam Cong-Nhat
    BDJ OPEN, 2024, 10 (01)
  • [4] Effect of Smoking Habits on Accuracy of Implant Placement Using Mucosally Supported Stereolithographic Surgical Guides
    D'haese, Jan
    De Bruyn, Hugo
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2013, 15 (03) : 402 - 411
  • [5] Effect of Manufacturing Technique on the Accuracy of Surgical Guides for Static Computer-Aided Implant Surgery
    Abduo, Jaafar
    Lau, Douglas
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2020, 35 (05) : 931 - 938
  • [6] Effects of autoclave sterilization on the dimensional stability of implant surgical guides: A 3D in vitro analysis
    Lo Russo, Lucio
    Mariani, Pierluigi
    Ercoli, Carlo
    Caprio, Giusy
    Park, Ji-Man
    Laino, Luigi
    Esperouz, Fariba
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2025,
  • [7] Three-Dimensional Accuracy of Surgical Guides for Static Computer-Aided Implant Surgery: A Systematic Review
    Lo Russo, Lucio
    Pierluigi, Mariani
    Zhurakivska, Khrystyna
    Digregorio, Chiara
    Lo Muzio, Eleonora
    Laino, Luigi
    PROSTHESIS, 2023, 5 (03): : 809 - 825
  • [8] Effect of cooling methods on dimensional accuracy and surface finish in reaming
    Islam M.N.
    Boswell B.
    International Journal of Machining and Machinability of Materials, 2019, 21 (03) : 187 - 213
  • [9] Effects of two Postprocessing Methods onto Surface Dimension of in-Office Fabricated Stereolithographic Implant Surgical Guides
    Ammoun, Rami
    Dalal, Nishchal
    Abdulmajeed, Aous A.
    Deeb, George R.
    Bencharit, Sompop
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2021, 30 (01): : 71 - 75
  • [10] Influence of the tooth position, guided sleeve height, supporting length, manufacturing methods, and resin E-modulus on the in vitro accuracy of surgical implant guides in a free-end situation
    Kessler, Andreas
    Le, Vinzenz
    Folwaczny, Matthias
    CLINICAL ORAL IMPLANTS RESEARCH, 2021, 32 (09) : 1097 - 1104