Influence of Screw Angulation on the Mechanical Properties on a Polyaxial Locking Plate Fixation

被引:0
|
作者
Martinez-Fortun, Gabriel [1 ]
Yanez, Alejandro [1 ]
Cuadrado, Alberto [1 ]
机构
[1] Univ Palmas Gran Canaria, Dept Mech Engn, Las Palmas Gran Canaria 35017, Spain
来源
BIOENGINEERING-BASEL | 2024年 / 11卷 / 10期
关键词
veterinary medicine; polyaxial screws; angulation; locking plates; cycling test;
D O I
10.3390/bioengineering11101024
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Polyaxial locking systems are widely used for strategic surgical placement, particularly in cases of osteoporotic bones, comminuted fractures, or when avoiding pre-existing prosthetics. However, studies suggest that polyaxiality negatively impacts system stiffness. We hypothesize that a new plate design, combining a narrow plate with asymmetric holes and polyaxial capabilities, could outperform narrow plates with symmetric holes. Three configurations were tested: Group 1 with six orthogonal screws, and Groups 2 and 3 with polyaxiality in the longitudinal and transverse axes, respectively. A biomechanical model assessed the bone/plate/screw interface under cyclic compression (5000 cycles) and torsion loads until failure. Screws were inserted up to 10 degrees angle. None of the groups showed a significant loss of stiffness during compression (p > 0.05). Group 1 exhibited the highest initial stiffness, followed by Group 3 (<29%) and Group 2 (<35%). In torsional testing, Group 1 achieved the most load cycles (29.096 +/- 1.342), while Groups 2 and 3 showed significantly fewer cycles to failure (6.657 +/- 3.551 and 4.085 +/- 1.934). These results confirm that polyaxiality, while beneficial for surgical placement, reduces biomechanical performance under torsion. Despite this, no group experienced complete decoupling of the screw-plate interface, indicating the robustness of the locking mechanism even under high stress.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Mechanical Performance of a Polyaxial Locking Plate and the Influence of Screw Angulation in a Fracture Gap Model
    Kaczmarek, Jakub
    Bartkowiak, Tomasz
    Schuenemann, Riccarda
    Paczos, Piotr
    Gapinski, Bartosz
    Bogisch, Sandra
    Unger, Martin
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2020, 33 (01) : 36 - 44
  • [2] Effect of Screw Insertion Torque on Mechanical Properties of a Hybrid Polyaxial Locking System
    Jung, Hey-Jin
    Jang, Aram
    Yim, Hyeong-Jun
    Han, Chang-Hoon
    Lee, Jae-Hoon
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2021, 34 (01) : 17 - 23
  • [3] Effect of screw angulation and multiple insertions on load-to-failure of polyaxial locking system
    Glowacki, Jakub
    Bartkowiak, Tomasz
    Paczos, Piotr
    Mietlinski, Patryk
    Zawadzki, Pawel
    Lapaj, Lukasz
    PLOS ONE, 2023, 18 (12):
  • [4] Mechanical Comparison of Headless Screw Fixation and Locking Plate Fixation for Talar Neck Fractures
    Karakasli, Ahmet
    Hapa, Onur
    Erduran, Mehmet
    Dincer, Cemal
    Cecen, Berivan
    Havitcioglu, Hasan
    JOURNAL OF FOOT & ANKLE SURGERY, 2015, 54 (05): : 905 - 909
  • [5] Effect of screw angulation on the bending performance of polyaxial locking interfaces: a micro-CT evaluation
    Glowacki, Jakub
    Bartkowiak, Tomasz
    Paczos, Piotr
    Gapinski, Bartosz
    Mietlinski, Patryk
    Zawadzki, Pawel
    Weiss, Weronika
    Lapaj, Lukasz
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [6] The effect of screw angulation and insertion torque on the push-out strength of polyaxial locking screws and the single cycle to failure in bending of polyaxial locking plates
    Bufkin, B. W.
    Barnhart, M. D.
    Kazanovicz, A. J.
    Naber, S. J.
    Kennedy, S. C.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2013, 26 (03) : 186 - 191
  • [7] Effect of screw angulation on the bending performance of polyaxial locking interfaces: a micro-CT evaluation
    Jakub Glowacki
    Tomasz Bartkowiak
    Piotr Paczos
    Bartosz Gapinski
    Patryk Mietlinski
    Pawel Zawadzki
    Weronika Weiss
    Lukasz Lapaj
    Scientific Reports, 13 (1)
  • [8] Polyaxial locking plate fixation in distal femur fractures: A biomechanical comparison
    Wilkens, Kenneth J.
    Curtiss, Shane
    Lee, Mark A.
    JOURNAL OF ORTHOPAEDIC TRAUMA, 2008, 22 (09) : 624 - 628
  • [9] Early Clinical Outcomes of Polyaxial Locking Cap Plate Fixation for Fixation of Displaced Olecranon Fractures
    Gutman, Michael Jason
    Patel, Manan Sunil
    Connelly, James William
    Paxton, Edward Scott
    Namdari, Surena
    Horneff, John Gabriel
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2025, 13 (01): : 23 - 29
  • [10] Mechanical Comparison of Cortical Screw Fixation Versus Locking Plate Fixation in First Metatarsal Base Osteotomy
    Smith, Kevin
    Lidtke, Roy H.
    Oliver, Noah G.
    Maker, Jared M.
    JOURNAL OF FOOT & ANKLE SURGERY, 2014, 53 (05): : 529 - 533