Distortion correction method for SEM images based on sampling moiré patterns and its application to characterization of the microscale fatigue crack propagation

被引:0
|
作者
Chen, R. [1 ]
Zhang, C. H. [1 ]
Xue, H. W. [1 ]
Li, S. Q. [1 ]
Xie, H. M. [1 ]
Zhang, Z. F. [1 ]
机构
[1] Tsinghua Univ, Sch Aerosp Engn, AML, Beijing 100084, Peoples R China
基金
中国国家自然科学基金;
关键词
distortion correction; scanning electron microscopy; sampling moir & eacute; method; time drift; spatial distortion; fatigue crack characterization; SCANNING-ELECTRON-MICROSCOPY; LARGE-DEFORMATION MEASUREMENTS; QUANTITATIVE SMALL; MAGNIFICATIONS; DRIFT;
D O I
10.1088/1361-6501/adbc08
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Scanning electron microscopy (SEM) is a crucial technique for characterizing mechanical behavior at micro- and nano-scales. However, image distortions inherent to SEM can undermine the accuracy and reliability of these measurements, and thus, the distortion correction of image is essential for realizing precise measurement. In this study, a correction method for SEM image distortion based on sampled moir & eacute; has been developed to achieve high accuracy measurement of the deformation field. This method could effectively correct both time drift and spatial distortion of SEM image. Following the application of distortion correction, the average coordinate virtual displacement caused by spatiotemporal distortion can be corrected by over 80%. On this basis, nickel-based superalloy GH4169 was selected for microscale fatigue propagation experiments. An in-situ fatigue loading platform within the SEM was employed to observe the initiation and propagation of fatigue cracks in real time. The proposed correction method allowed for accurate measurement of microscale fatigue crack propagation parameters and quantitative characterization of the crack closure effect.
引用
收藏
页数:13
相关论文
共 7 条
  • [1] A DISTORTION CORRECTION METHOD FOR ENDOSCOPE IMAGES BASED ON CALIBRATION PATTERNS AND A SIMPLE MATHEMATIC MODEL FOR OPTICAL LENS
    Hsu, Chieh-Hao
    Miaou, Shaou-Gang
    Chang, Feng-Ling
    BIOMEDICAL ENGINEERING-APPLICATIONS BASIS COMMUNICATIONS, 2005, 17 (06): : 309 - 318
  • [2] Fatigue Crack Growth Rate Curve Based on the CJP Model and Its Application Method
    Yang B.
    James M.N.
    2018, Chinese Mechanical Engineering Society (54): : 76 - 84
  • [3] A global method based on thin-plate splines for correction of geometric distortion: An application to fluoroscopic images
    Fantozzi, S
    Cappello, A
    Leardini, A
    MEDICAL PHYSICS, 2003, 30 (02) : 124 - 131
  • [4] Application of configurational mechanics in characterizing contact fatigue life and its crack propagation: a numerical lattice-based approach
    Mohammadipour, Amir
    Willam, Kaspar
    COMPUTATIONAL MECHANICS, 2019, 63 (06) : 1301 - 1313
  • [5] Application of configurational mechanics in characterizing contact fatigue life and its crack propagation: a numerical lattice-based approach
    Amir Mohammadipour
    Kaspar Willam
    Computational Mechanics, 2019, 63 : 1301 - 1313
  • [6] Crack propagation characterization and statistical evaluation of fatigue life for locally corroded bridge steel based on metal magnetic memory method
    Su, Sanqing
    Yang, Yiyi
    Wang, Wei
    Ma, Xiaoping
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2021, 536
  • [7] A finite element method with mesh-separation-based approximation technique and its application in modeling crack propagation with adaptive mesh refinement
    Ling, Daosheng
    Bu, Lingfang
    Tu, Fubin
    Yang, Qingda
    Chen, Yunmin
    INTERNATIONAL JOURNAL FOR NUMERICAL METHODS IN ENGINEERING, 2014, 99 (07) : 487 - 521