Magnetoelectrics for Implantable Bioelectronics: Progress to Date

被引:1
|
作者
Alrashdan, Fatima [1 ]
Yang, Kaiyuan [1 ]
Robinson, Jacob T. [1 ,2 ,3 ,4 ]
机构
[1] Rice Univ, Dept Elect & Comp Engn, Houston, TX 77005 USA
[2] Rice Univ, Dept Bioengn, Houston, TX 77005 USA
[3] Rice Univ, Appl Phys Program, Houston, TX 77005 USA
[4] Baylor Coll Med, Dept Neurosci, 1 Baylor Plaza, Houston, TX 77030 USA
关键词
COMPOSITE-MATERIAL; STIMULATION;
D O I
10.1021/acs.accounts.4c00307
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The coupling of magnetic and electric properties manifested in magnetoelectric (ME) materials has unlocked numerous possibilities for advancing technologies like energy harvesting, memory devices, and medical technologies. Due to this unique coupling, the magnetic properties of these materials can be tuned by an electric field; conversely, their electric polarization can be manipulated through a magnetic field. Over the past seven years, our lab work has focused on leveraging these materials to engineer implantable bioelectronics for various neuromodulation applications. One of the main challenges for bioelectronics is to design miniaturized solutions that can be delivered with minimally invasive procedures and yet can receive sufficient power to directly stimulate tissue or power electronics to perform functions like communication and sensing. Magnetoelectric coupling in ME materials is strongest when the driving field matches a mechanical resonant mode. However, miniaturized ME transducers typically have resonance frequencies >100 kHz, which is too high for direct neuromodulation as neurons only respond to low frequencies (typically <1 kHz). We discuss two approaches that have been proposed to overcome this frequency mismatch: operating off-resonance and rectification. The off-resonance approach is most common for magnetoelectric nanoparticles (MENPs) that typically have resonance frequencies in the gigahertz range. In vivo experiments on rat models have shown that MENPs could induce changes in neural activity upon excitation with <200 Hz magnetic fields. However, the neural response has latencies of several seconds due to the weak coupling in the off-resonance regime. To stimulate neural responses with millisecond precision, we developed methods to rectify the ME response so that we could drive the materials at their resonant frequency but still produce the slowly varying voltages needed for direct neural stimulation. The first version of the stimulator combined a ME transducer and analog electronics for rectification. To create even smaller solutions, we introduced the first magnetoelectric metamaterial (MNM) that exhibits self-rectification. Both designs have effectively induced neural modulation in rat models with less than 5 ms latency. Based on our experience with in vivo testing of the rectified ME stimulators, we found it challenging to deliver the precisely controlled therapy required for clinical applications, given the ME transducer's sensitivity to the external transmitter alignment. To overcome this challenge, we developed the ME-BIT (MagnetoElectric BioImplanT), a digitally programmable stimulator that receives wireless power and data through the ME link. We further expanded the utility of this technology to neuromodulation applications that require high stimulation thresholds by introducing the DOT (Digitally programmable Overbrain Therapeutic). The DOT has voltage compliance up to 14.5 V. We have demonstrated the efficacy of these designs through various in vivo studies for applications like peripheral nerve stimulation and epidural cortical stimulation. To further improve these systems to be adaptive and enable a network of coordinated devices, we developed a bidirectional communication system to transmit data to and from the implant. To enable even greater miniaturization, we developed a way to use the same ME transducer for wireless power and data communication by developing the first ME backscatter communication protocol.
引用
收藏
页码:2953 / 2962
页数:10
相关论文
共 50 条
  • [1] Recent Progress in Semi-Implantable Bioelectronics for Precision Health Monitoring
    Chen, Wenting
    Zheng, Xinyu
    Zhou, Yue
    Du, Wanyu
    Liang, Fei
    Yu, Hai-Dong
    Li, Linlin
    ADVANCED FUNCTIONAL MATERIALS, 2025,
  • [2] Implantable Batteries for Bioelectronics
    Jiao, Yiding
    He, Er
    Ye, Tingting
    Wang, Yuanzhen
    Yin, Haotian
    Zhang, Ye
    ACCOUNTS OF MATERIALS RESEARCH, 2025, 6 (02): : 221 - 232
  • [3] Soft Implantable Bioelectronics
    Koo, Ja Hoon
    Song, Jun-Kyul
    Kim, Dae-Hyeong
    Son, Donghee
    ACS MATERIALS LETTERS, 2021, 3 (11): : 1528 - 1540
  • [4] PROGRESS IN BIOELECTRONICS
    SCANTLAND, DA
    GATZ, RL
    BIO-TECHNOLOGY, 1983, 1 (06): : 492 - 493
  • [5] Semi-Implantable Bioelectronics
    Jiaru Fang
    Shuang Huang
    Fanmao Liu
    Gen He
    Xiangling Li
    Xinshuo Huang
    Hui-jiuan Chen
    Xi Xie
    Nano-Micro Letters, 2022, 14 (07) : 360 - 414
  • [6] Semi-Implantable Bioelectronics
    Fang, Jiaru
    Huang, Shuang
    Liu, Fanmao
    He, Gen
    Li, Xiangling
    Huang, Xinshuo
    Chen, Hui-jiuan
    Xie, Xi
    NANO-MICRO LETTERS, 2022, 14 (01)
  • [7] Fibrous wearable and implantable bioelectronics
    Sadri, Behnam
    Gao, Wei
    APPLIED PHYSICS REVIEWS, 2023, 10 (03)
  • [8] Ionic communication for implantable bioelectronics
    Zhao, Zifang
    Spyropoulos, George D.
    Cea, Claudia
    Gelinas, Jennifer N.
    Khodagholy, Dion
    SCIENCE ADVANCES, 2022, 8 (14)
  • [9] Semi-Implantable Bioelectronics
    Jiaru Fang
    Shuang Huang
    Fanmao Liu
    Gen He
    Xiangling Li
    Xinshuo Huang
    Hui-jiuan Chen
    Xi Xie
    Nano-Micro Letters, 2022, 14
  • [10] Guest Editorial: Implantable bioelectronics
    Hanein, Yael
    Goding, Josef
    APL BIOENGINEERING, 2024, 8 (02):