Reliability of shear wave elastography for cervical and lumbar fascia stiffness and thickness in healthy and chronic neck and low back pain subjects

被引:0
|
作者
Zandi, Soodeh [1 ,2 ,3 ]
Mokhtarinia, Hamid Reza [1 ,4 ]
Mosallanezhad, Zahra [1 ,2 ,3 ]
Mobin, Hadi Karimi [5 ]
Arab, Amir Massoud [1 ,3 ]
Azadi, Farhad [1 ,3 ]
Noroozi, Mehdi [6 ,7 ]
机构
[1] Univ Social Welf & Rehabil Sci, Neuromusculoskeletal Rehabil Res Ctr, Tehran, Iran
[2] Univ Social Welf & Rehabil Sci, Rofeideh Rehabil Hosp, Clin Res Dev Ctr, Tehran, Iran
[3] Univ Social Welf & Rehabil Sci, Dept Phys Therapy, Tehran, Iran
[4] Univ Social Welf & Rehabil Sci, Dept Ergon, Tehran, Iran
[5] Army Univ Med Sci, Radiol Dept, Tehran, Iran
[6] Univ Social Welf & Rehabil Sci, Dept Psychiat, Tehran, Iran
[7] Univ Social Welf & Rehabil Sci, Subst Abuse & Dependence Res Ctr, Tehran, Iran
关键词
Shear wave elastography; Low back pain; Neck pain; Thoracolumbar fascia; Elasticity; Reliability; ULTRASOUND ELASTOGRAPHY; MUSCLE; ELASTICITY; TENDON; SONOELASTOGRAPHY; PALPATION;
D O I
10.1016/j.jbmt.2025.01.021
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Purpose: This study had two primary aims: first, to assess the reliability of shear wave elastography (SWE) in measuring the stiffness of the posterior cervical fascia, the posterior layer of the lumbar fascia, and fascia thickness; and second, to compare these fascial properties between healthy individuals and patients with chronic neck and low back pain (LBP). Methods: Thirty participants, including 15 with concurrent neck and LBP and 15 healthy controls, were enrolled. The stiffness and thickness of the fascia, as well as the ratio of fascia stiffness to subcutaneous fat stiffness, were measured in the lumbar and cervical regions. Measurements were performed twice by a single examiner over 1-3 days. Reliability was assessed using the Intraclass Correlation Coefficient (ICC), Standard Error of Measurement (SEM), Minimal Detectable Change (MDC), and Bland-Altman plots. Independent t-tests were conducted to compare group differences. Results: Test-retest reliability for the stiffness of the fascia in the cervical and lumbar regions was excellent, with ICC(3,1) values >= 0.90. Fascia thickness and the ratio showed good to excellent reliability (ICC(3,1) >= 0.80). The SEM, MDC, and limits of agreement supported these findings. Patients with neck and LBP had significantly thicker lumbar fascia than healthy controls (p = 0.002), while no significant differences were found in stiffness between the groups. Conclusion: This study confirms the reliability of SWE in assessing fascia properties. While the lumbar fascia was thicker in patients with neck and low back pain, no significant differences in stiffness were observed between the groups.
引用
收藏
页码:558 / 566
页数:9
相关论文
共 50 条
  • [1] Reliability of shear-wave elastography in assessing the stiffness of the nuchal fascia and the thickness of upper cervical muscles
    Liao, Lin-Rong
    Pan, Hong-Hua
    Diao, Ying-Xiu
    Xie, Yi
    Liao, Man-Xia
    Xie, Yu-Hua
    MEDICAL ENGINEERING & PHYSICS, 2023, 120
  • [2] Influence of thoracolumbar fascia stretching on lumbar back muscle stiffness: A supersonic shear wave elastography approach
    Blain, Maxime
    Bedretdinova, Dina
    Bellin, Marie-France
    Rocher, Laurence
    Gagey, Olivier
    Soubeyrand, Marc
    Creze, Maud
    CLINICAL ANATOMY, 2019, 32 (01) : 73 - 80
  • [3] Shear wave elastography investigation of multifidus stiffness in individuals with low back pain
    Murillo, Carlos
    Falla, Deborah
    Rushton, Alison
    Sanderson, Andy
    Heneghan, Nicola R.
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2019, 47 : 19 - 24
  • [4] Neck Muscle Stiffness Measured With Shear Wave Elastography in Women With Chronic Nonspecific Neck Pain
    Dieterich, Angela V.
    Yavuz, Utku Sukru
    Petzke, Frank
    Nordez, Antoine
    Falla, Deborah
    JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 2020, 50 (04): : 179 - 188
  • [5] Neck Muscle Stiffness in Participants With and Without Chronic Neck Pain: A Shear-Wave Elastography Study
    Tas, Serkan
    Korkusuz, Feza
    Erden, Zafer
    JOURNAL OF MANIPULATIVE AND PHYSIOLOGICAL THERAPEUTICS, 2018, 41 (07) : 580 - 588
  • [6] Reliability of shear wave elastography for the assessment of gastrocnemius fascia elasticity in healthy individual
    Zhou, Jiping
    Lin, Yuyi
    Zhang, Jiehong
    Si'tu, Xingxian
    Wang, Ji
    Pan, Weiyi
    Wang, Yulong
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [7] Reliability of shear wave elastography for the assessment of gastrocnemius fascia elasticity in healthy individual
    Jiping Zhou
    Yuyi Lin
    Jiehong Zhang
    Xingxian Si’tu
    Ji Wang
    Weiyi Pan
    Yulong Wang
    Scientific Reports, 12
  • [8] Reliability of shear-wave elastography in assessing thoracolumbar fascia elasticity in healthy male
    Baizhen Chen
    Hongzhou Zhao
    Linrong Liao
    Zhijie Zhang
    Chunlong Liu
    Scientific Reports, 10
  • [9] Reliability of shear-wave elastography in assessing thoracolumbar fascia elasticity in healthy male
    Chen, Baizhen
    Zhao, Hongzhou
    Liao, Linrong
    Zhang, Zhijie
    Liu, Chunlong
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [10] Noninvasive Measurement of Sciatic Nerve Stiffness in Patients With Chronic Low Back Related Leg Pain Using Shear Wave Elastography
    Neto, Tiago
    Freitas, Sandro R.
    Andrade, Ricardo J.
    Vaz, Joao R.
    Mendes, Bruno
    Firmino, Telmo
    Bruno, Paula M.
    Nordez, Antoine
    Oliveira, Raul
    JOURNAL OF ULTRASOUND IN MEDICINE, 2019, 38 (01) : 157 - 164